Teslas on one side, gauss on the other
Magnetic flux density, written B, measures the strength of a magnetic field in terms of the force it exerts on moving charge. The SI unit is the tesla (T), named for Nikola Tesla, and one tesla equals one weber per square meter. The older CGS unit is the gauss (G), named for Carl Friedrich Gauss. One gauss equals 10^-4 T, which is 100 µT. This hub has 43 converters, led by the Magnetic flux density converter, linking teslas, milliteslas, microteslas, nanoteslas, picoteslas, gauss and milligauss. In North America, field meters and older equipment still read gauss, while scientific papers use teslas.
A ladder with two kinds of step
Within the SI family each prefix is 1,000 apart. The gauss family connects to the tesla family through 10^-4: 1 T is 10,000 G, 1 mT is 10 G, 1 µT is 10 mG, and 1 G is 100 µT. The Teslas to Gauss converter multiplies by 10,000, the Microteslas to Milligauss converter multiplies by 10, and the Milligauss to Microteslas converter divides by 10. A reading of 50 µT is therefore 0.5 G, or 500 mG. The Nanoteslas to Gauss converter handles sensor data: 25,000 nT is 0.25 G. Because both the 1,000 and the 10,000 factors show up, errors of a factor of 10 are the usual mistake.
Earth and the compass
Earth field at the surface ranges from about 25 µT near the equator in parts of South America to about 65 µT near the poles. A typical mid-latitude value of 50 µT equals 0.5 G, and the Microteslas to Gauss converter confirms it. Smartphone magnetometers report in microteslas, and a compass app showing 45 µT is consistent with Earth field. A refrigerator magnet delivers on the order of 5 mT at its surface, which is 50 G. Strong neodymium magnets reach 0.3 to 0.5 T at the pole face, and clinical MRI scanners operate at 1.5 or 3 T, tens of thousands of times Earth field. Scale references help catch a misplaced prefix. Aircraft, ships and vehicles carry compasses that must be corrected for the iron around them, and a deviation card records how many degrees the needle strays. The disturbing field is often only a few microteslas, which the Microteslas to Gauss converter writes as hundredths of a gauss, small compared with Earth field but enough to throw a bearing off by several degrees. Magnetometer apps also show noise of about one microtesla, so tiny differences between readings carry little meaning.
Milligauss and household field meters
Hand-held extremely-low-frequency (ELF) meters in the United States read in milligauss. A reading of 2 mG is 0.2 µT, and the Milligauss to Microteslas converter gives that directly. Field levels near household appliances vary widely with distance: a few mG at a few feet from a refrigerator is common, and values fall rapidly with distance. ICNIRP 2010 guidelines give a reference level of 200 µT for public exposure to 50 Hz fields and 1 mT for occupational exposure, which the Microteslas to Milligauss converter turns into 2,000 mG and 10,000 mG. Use the original guideline text for compliance, and treat this hub as a unit helper, not as a safety assessment.
Nanoteslas and picoteslas in geophysics and biomagnetism
Geomagnetic surveys detect anomalies of a few nanoteslas against a background of 50,000 nT. A magnetic storm can shift Earth field by hundreds of nanoteslas, and the Nanoteslas to Microteslas converter turns 300 nT into 0.3 µT. Biomagnetic signals are far smaller: the field of the human heart is about 50 pT at the chest, and brain signals measured by magnetoencephalography are in the range of tens to hundreds of femtoteslas. The Teslas to Picoteslas converter and the Picoteslas to Nanoteslas converter handle the intermediate range. Shielding rooms with high-permeability alloys are used to reduce ambient fields to this level before measurement.
Gauss in magnet specifications
Permanent magnet suppliers describe a magnet by its remanence Br and its surface field. A grade N42 neodymium magnet has Br of about 1.3 T, which the Teslas to Gauss converter lists as 13,000 G. Pull force depends on the area and the gap, so the surface gauss reading of a given magnet varies with shape and probe position. The Gauss to Milliteslas converter gives 13,000 G as 1,300 mT. Gaussmeters are calibrated against reference magnets, and a reading with a Hall probe held a millimeter off the surface can drop sharply. Compare data sheets only when the measurement method is the same. Speaker magnets, motor rotors and holding magnets are usually specified by the field in the air gap rather than at the surface, and values of 0.8 to 1.2 T (8,000 to 12,000 G) are common for loudspeaker gaps. A ferrite magnet has a lower remanence near 0.4 T, which the Teslas to Gauss converter gives as 4,000 G, and this difference of three to one explains why a ferrite motor needs more magnet volume than a neodymium one for the same torque.
Gauss versus oersted
Gauss measures B, and oersted measures H. In vacuum 1 G corresponds to 1 Oe, because B = μ0H in SI and the CGS system builds the equality in. In a magnetic material the two differ by a large factor. A transformer steel at 10,000 G might be responding to an H of only a few oersteds. The magnetic field strength topic on this site converts H units. Use this hub only for B values. If a source says gauss when it means oersteds, as some older documents do, the numeric equality in air hides the mistake, but inside iron it will lead to errors of orders of magnitude.
Choosing among 43 tools
Read the title from left to right: the first unit is your source and the second is your target. The Teslas to Milliteslas converter and Milliteslas to Teslas converter move by 1,000, and the cross-family pairs such as the Gauss to Microteslas converter combine the 10^-4 factor with the prefix. For a quick check, remember that 1 mT is 10 G, and 1 µT is 10 mG. If an answer misses by 10, you probably used the tesla to gauss factor of 10,000 where you wanted 1,000. Write the unit beside each number in your notes. Mixed sets such as 0.5 G, 50 µT and 500 mG are all the same field. Sensor data sheets complicate matters by quoting sensitivity in mV per gauss or mV per millitesla, and a conversion of the unit in the denominator inverts the factor: 5 mV/G is 50 mV/mT, not 0.5. Handle the denominator with care, since multiplying instead of dividing changes the result by a factor of 100 when the prefix and the CGS step are both involved.
Frequently asked questions
- How many gauss are in one tesla?
- 10,000. One gauss is 10^-4 T, which is 100 µT.
- What is Earth magnetic field in gauss?
- About 0.25 to 0.65 G depending on location, typically near 0.5 G or 50 µT at mid-latitudes.
- How do I convert milligauss to microtesla?
- Divide by 10. A reading of 2 mG is 0.2 µT, which the Milligauss to Microteslas converter reports.
- Is gauss the same as oersted?
- They are different quantities, B and H. In vacuum 1 G corresponds to 1 Oe, but in magnetic materials they differ widely.