From magnets to magnetometers

Milliteslas are the usual unit for the field of a small magnet, a solenoid or a sensor test coil. Microteslas are the unit of the Earth's field and of the readings from a phone magnetometer. When a sensor data sheet gives its range in millitesla and an app reports microtesla, the two have to be reconciled. This converter takes a value in milliteslas and returns microteslas by multiplying by 1,000. The default 10 mT gives 10,000 µT. The page changes the unit of a flux density you already know. It does not estimate how a field varies with distance, whether a magnet will saturate a sensor or whether a field is safe for a person or device. Because the conversion is exact, you can verify any result by eye, and the page works as a quick check on spreadsheet columns.

The factor of 1,000

The prefixes milli and micro are 10⁻³ and 10⁻⁶. The ratio of a millitesla to a microtesla is therefore 10⁻³ divided by 10⁻⁶, which is 1,000. The page formula reads µT = mT × 1000.00000000. Both prefixes are exact powers of ten in the SI Brochure from the BIPM, so the factor is exact. The tesla itself is the SI derived unit of magnetic flux density, one weber per square meter. A mnemonic for direction: the microtesla is the smaller unit, so the number gets bigger when you convert into it. A thousand small units make one large unit. The reverse conversion, from microtesla to millitesla, divides by 1,000, or shifts the decimal point three places to the left.

The default of 10 mT

The default 10 mT converts to 10,000 µT, which is also 100 gauss, 0.01 T and 100,000 mG. A simple check: 10 mT is 0.01 T, and 0.01 T divided by 10⁻⁶ T per microtesla gives 10,000. If your result has only two or three digits, you divided instead of multiplying. If it has seven digits, you multiplied by a million. A field of 10 mT is much stronger than the Earth's field, about 200 times a typical 50 µT. It is comparable to the field close to the surface of some small ceramic or flexible magnets, though real magnets vary a lot. Putting the default next to the Earth's field illustrates why magnetic compasses can be disturbed by a magnet held nearby.

Everyday magnets in millitesla

A refrigerator magnet has a surface flux density on the order of a few milliteslas, with a figure around 5 mT often quoted. A strong neodymium magnet reaches several hundred millitesla at its surface and can exceed a tesla within a magnetic circuit. Loudspeaker drivers rely on gap fields of the order of a tesla. A 5 mT field is 5,000 µT, about a hundred times Earth's field. These values are rough, because surface flux density depends on the magnet shape, the grade of material and the exact point of measurement. A data sheet figure is valid for a stated position and orientation. When you convert a figure to microtesla to compare with a magnetometer, use the same position and orientation, or the comparison will not be meaningful. A fridge magnet is about 300 times weaker than a 1.5 T clinical scanner, since 1,500 mT divided by 5 mT is 300.

MRI and the 5 gauss line

Medical magnetic resonance imaging scanners use static fields of 1.5 T or 3 T. In millitesla, those are 1,500 mT and 3,000 mT, and in microtesla 1,500,000 µT and 3,000,000 µT. The stray field outside the scanner falls with distance. Safety zones around scanners are often marked by the 0.5 mT contour, historically called the 5 gauss line, since 0.5 mT is 5 G. Access inside that contour is restricted for people with implanted devices such as pacemakers, according to usual safety practice. In microtesla, the contour is 500 µT. This page does not determine safe distances or limits. Those depend on the scanner, the site and the regulations, and they require a site-specific assessment by a qualified medical physicist. On the same scale, the Earth's field of 50 µT is 0.05 mT, ten thousand times weaker than a 500 mT magnet field.

Phone magnetometers and the Earth

The magnetometer in a phone reports in microtesla, and typical readings outdoors are between 25 and 65 µT. In millitesla, that is 0.025 to 0.065 mT. A reading of 10,000 µT would be an enormous number by comparison, and it would appear only if the phone were held against a strong magnet. In fact, the sensor may saturate before reaching that level, because phone magnetometers are designed for fields near that of the Earth, with ranges of a few thousand microtesla at most. Putting a magnet near a phone can disturb the compass and may require recalibration. Converting between millitesla and microtesla allows data sheet limits to be compared to the numbers an app displays. Many phone apps show the total field as well as three axis components in microtesla, and the same factor applies to each axis if you convert the readings one by one.

Gauss, oersted and the CGS legacy

One gauss is exactly 10⁻⁴ T, which is 0.1 mT or 100 µT. So 10 mT equals 100 G. Old magnet catalogs and many gaussmeters still use gauss, and older papers use the oersted for magnetic field strength, which is a different quantity. When you convert a figure in gauss to microtesla, multiply by 100. To go from gauss to millitesla, multiply by 0.1. For example, 50 G is 5 mT and 5,000 µT. NIST Special Publication 811 lists gauss among the CGS units outside the SI. The dropdown on this page includes gauss and milligauss, so you can choose them directly without hand calculation. The important point is to keep track of which of the several magnetic units your source uses, because several of them have similar names.

Hall sensors and their sensitivity

A Hall effect sensor produces a voltage proportional to the flux density through it. Data sheets specify sensitivity in millivolts per millitesla or millivolts per gauss. Since 1 G is 0.1 mT, a sensitivity of 1 mV/G is 10 mV/mT, and in microtesla it is 0.01 mV/µT. A sensor with 10 mV/mT sees a 120 mT field as 1.2 V above its zero level. Many linear Hall sensors cover ranges of tens to hundreds of millitesla, and switches trigger at a threshold of a few millitesla. When you design with them, convert the field you expect into the unit used on the data sheet, and check that the field stays within the linear range. The conversions here are only the unit step. They do not model the sensor. Temperature also shifts the zero level and sensitivity of many sensors, so data sheets give drift figures in percent per degree.

Worked examples

Convert 0.5 mT: multiply by 1,000 to get 500 µT, which is the 5 gauss contour field. Convert 120 mT: the result is 120,000 µT. Convert 1,500 mT, the field of a 1.5 T scanner: the result is 1,500,000 µT. For the reverse direction, 50 µT is 0.05 mT, found by swapping the units. A round trip returns the starting value. Another check goes through gauss: 120 mT is 1,200 G, and 1,200 G times 100 µT per gauss is 120,000 µT, the same result. These examples are illustrative values chosen to make the arithmetic simple. Where the numbers are long, group the digits in threes, as in 1,500,000, or use scientific notation, so that you can count zeros reliably. To go the other direction, a field of 2,500 µT is 2.5 mT.

How fields fall with distance

The field of a small magnet falls rapidly with distance. For an ideal magnetic dipole, the flux density along its axis decreases with the cube of the distance, so doubling the distance reduces the field to one eighth. An illustrative magnet that gives 10 mT at 5 cm would give about 1.25 mT, or 1,250 µT, at 10 cm in the far-field dipole approximation, and about 0.16 mT, or 156 µT, at 20 cm. Real magnets deviate from this at short range, where the shape matters. The rule explains why a magnet that affects a compass at a few centimeters is harmless at a meter. It also explains why measurements at different distances cannot be compared without knowing the distance. A conversion in units does not account for distance.

Static fields, alternating fields and RMS

The type of field matters. A static field from a magnet has a constant value. An alternating field, such as that near a transformer, has an amplitude and a frequency, and meters may report RMS or peak values. A sinusoidal field with a peak of 1 mT has an RMS value of about 0.707 mT. The conversion between millitesla and microtesla is the same for each, since only the unit scale changes. But comparing a peak value with an RMS value from another source leads to a factor of 1.414 error. Also note that instruments for alternating fields may not read static fields correctly, and the reverse. Record the field type next to the converted number.

Limits of the page

The converter changes the unit of a flux density. It does not calculate installation limits, equipment ratings, protection, material response or compliance. It does not say whether a field is safe for people, implants, data media or instruments. For definitions, see the BIPM SI Brochure and NIST Special Publication 811, and for safety questions use the relevant standards and a qualified professional. The factor is exact, so a difference between this page and another source nearly always comes from a different input unit.