Measurement basis
Relating B and H can require a material model and permeability. The factor conversion within B does not establish that context.
Definition conventions
This group measures B. H-to-B requires permeability and material information.
Conversion method
Use the stored flux-density factor ratio, preserving the B quantity label.
Choose the conversion direction
Confirm that the supplied measurement is flux density before selecting a tesla or gauss target.
The tesla and how it is defined
Magnetic flux density, written B, is measured in teslas, symbol T. The unit was named for Nikola Tesla by the General Conference on Weights and Measures in 1960. One tesla equals one weber per square meter, and in base units it is 1 kg/(s²·A). A particle with charge 1 C moving at 1 m/s perpendicular to a 1 T field feels a force of 1 N, which is the definition by the Lorentz force. In practice the tesla is a large unit, and most everyday fields are given in millitesla, microtesla or nanotesla. Scientific instruments span more than twelve orders of magnitude, from the faint fields of the human brain to the steady fields of large research magnets.
The gauss and its ratio to the tesla
The gauss, symbol G, belongs to the centimeter-gram-second system and is named after Carl Friedrich Gauss. One gauss equals 10^-4 T, which is 100 µT. So 1 T equals 10,000 G. Earth field near the surface is about 0.25 to 0.65 G, or 25 to 65 µT, and a reading of 0.5 G is the same as 50 µT. A milligauss is 0.1 µT, which is the unit often used for household electromagnetic field meters. A meter reading of 20 mG is therefore 2 µT. Using the factor 1 G = 0.0001 T, a ratio of 10^4, it is easy to check any conversion by moving the decimal four places.
A tour of magnitudes
The magnetic field of the human brain measured by magnetoencephalography is on the order of 10^-13 T, roughly 100 femtotesla. Earth field is about 50 µT. A fridge magnet shows around 5 mT at its surface, and a good neodymium magnet may reach 0.5 to 1.4 T at the pole face. Clinical MRI scanners usually run at 1.5 T or 3 T, with research scanners reaching 7 T and above. The strongest continuous fields in the laboratory are around 45 T, produced with hybrid superconducting and resistive magnets, and pulsed magnets exceed 100 T for a very short time. Listing these makes a prefix error stand out at once.
Exposure reference levels
Safety guidance for low-frequency fields is stated in microtesla. The ICNIRP 2010 guidelines give a reference level of 200 µT for the general public at 50 Hz, and 1000 µT for occupational exposure. At the more common unit used by household meters, 200 µT is 2000 mG. Typical fields in homes at 50 or 60 Hz are far below this, often under 0.1 µT away from appliances and power lines. Because meters, standards and regulations differ in whether they use mG or µT, the factor of 10 between them, 1 mG = 0.1 µT, appears constantly in this subject. This guide covers units, and it does not judge compliance.
The relation with field strength H
In vacuum, flux density B and field strength H are linked by B = μ0 H, with μ0 about 1.2566 × 10^-6 T·m/A. A field of 1 T in air then corresponds to H of about 795.8 kA/m. In magnetic materials the relation becomes B = μ0(H + M), where M is the magnetization, so the same H can give very different B. The gauss and the oersted coincide numerically in vacuum, which is why the two names are sometimes used loosely. In SI, the two quantities have different units and cannot be converted without the material information.
Flux density from flux and area
When a uniform flux passes perpendicular to an area, B equals the flux divided by the area. A flux of 2 mWb through 25 cm², which is 0.0025 m², gives B = 0.8 T. The same flux through half that area gives 1.6 T, which is near saturation for many electrical steels. This simple ratio sits behind transformer design, where designers pick a core area to keep B below the saturation level. Estimating this requires the area unit to match, and mixing cm² with m² is a common source of an error of 10,000. The weber per square meter route is also the quickest check of the unit.
Measuring a field
Hall-effect sensors, fluxgate magnetometers and search coils measure flux density by different principles. A Hall sensor reports a voltage that scales with B, with sensitivities such as a few millivolts per millitesla. Fluxgates reach nanotesla resolution and are used in geophysics and in spacecraft. Proton precession magnetometers measure the magnitude of Earth field through the Larmor frequency, which is about 42.58 MHz per tesla for protons. That link means a measured frequency of 2.129 kHz corresponds to about 50 µT. Instrument manuals list the range and resolution in their own unit, so a technician might work in G, mT and nT in one session. Calibration of a gaussmeter often uses a Helmholtz coil, whose central field is about 0.7155 μ0 N I / R, so 100 turns at 1 A with a 10 cm radius gives roughly 0.9 mT, which is 9 G on the instrument.
Symbols and conversions to avoid mistaking
The symbol for tesla is a capital T, and a lowercase t is the metric ton. The symbol for millitesla is mT, while mt would read as milli-ton and is not used. Microtesla is µT or uT. The converter handles T, mT, µT, nT, pT, G and mG, and every factor is a power of ten, with the gauss pair set by 1 G = 10^-4 T. Converting a gauss reading to tesla is dividing by 10,000, so 3500 G is 0.35 T. A field strength in A/m cannot be handled by this tool, and it does not compute forces, shielding or exposure limits.
Related quantities with similar names
Magnetic flux density is sometimes called magnetic induction or simply the magnetic field, and the last label leads to confusion with H. Flux, in webers, is the total through an area. Magnetization M has the unit A/m, the same as H. Remanence, the flux density left in a magnet after the applied field is removed, is quoted in teslas or gauss, and a magnet grade with a remanence of 1.3 T has 13,000 G, or 13 kG, on a datasheet. Keeping each name tied to its unit and its role avoids reading a number in the wrong sense even when the symbol looks familiar. A permanent magnet remanence of 1.3 T, a coil field of 1.3 mT and a stray field of 1.3 µT differ by factors of 1000 each, so a prefix is never a detail.
Precision and checking
- Retain the source B measurement precision.
- Keep material context separately when comparing B with H.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Teslas (T)
Definition, reference values and linked conversions.
Milliteslas (mT)
Definition, reference values and linked conversions.
Microteslas (µT)
Definition, reference values and linked conversions.
Nanoteslas (nT)
Definition, reference values and linked conversions.
Gauss (G)
Definition, reference values and linked conversions.
Milligauss (mG)
Definition, reference values and linked conversions.
Picoteslas (pT)
Definition, reference values and linked conversions.
Use a working converter
- Magnetic flux density converter
- Teslas to Milliteslas converter
- Milliteslas to Teslas converter
- Teslas to Microteslas converter
- Microteslas to Teslas converter
- Teslas to Nanoteslas converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.