The scale of everyday magnetometers

Most small magnetic sensors report in microteslas. A smartphone magnetometer, the compass chip in a drone, a handheld field meter and a pocket EMF detector all show values in µT, because the fields around us are far below one tesla. A tesla is the unit used for strong magnets and scanners. When a data sheet states a limit in teslas and your sensor reads in microteslas, you need the factor. This page multiplies by 1,000,000. The default 10 T becomes 10,000,000 µT, and a 3 T scanner becomes 3,000,000 µT. The factor is exact, since the prefix micro is defined as 10^-6. Datasheets for sensors list resolution in µT as well, so the same unit shows up on both the field and the instrument.

Six zeros added

With 10 T entered, the page returns 10,000,000 µT. A check: the prefix gap of one million adds six zeros to the 10, which gives 10,000,000. For smaller values the same rule applies, so 0.002 T is 2,000 µT, and 0.0000045 T is 4.5 µT. A common slip is using 1,000, which is the factor for millitesla, so a result that is a thousand times too small points to that mistake. Working on the prefix ladder helps: 1 T is 1,000 mT, and each millitesla is 1,000 µT. The three-step ladder from tesla to millitesla to microtesla gives 1,000 times 1,000, which is the million you need.

Earth's field as a yardstick

The Earth's field at the surface falls between about 25 µT and 65 µT depending on latitude and location. A phone magnetometer that reads 48 µT is giving a typical value for many places. In those units, a 10 T field is 10,000,000 µT, which is about 200,000 times a 50 µT Earth field (10,000,000 divided by 50). This is the reason a strong magnet can ruin a compass reading even at a distance of a meter or more. The Earth's field comparison is a helpful sanity check when you read a sensor, because a value near 50 µT is normal, and a value several times larger suggests nearby steel or a magnet. Local variation matters: the vertical and horizontal components change with latitude, so the total can differ by a factor of two between places.

Phone and drone compasses

A compass sensor can be thrown off by a magnetic case, a speaker, a steel desk or a power cable. Apps that display the field strength in µT make the problem visible: if the number jumps far from the usual local value when you move the phone, something is interfering. Calibration routines, such as waving the device in a figure eight, estimate the offsets that come from the device itself. The sensor does not measure in teslas, but the conversion helps when you compare its output with a figure from a data sheet or a magnet maker that uses larger units. A magnet at 0.3 T on its surface is 300,000 µT. Moving away from the interference, or recalibrating, brings the reading back toward the local value.

How quickly a field falls with distance

The field of a small magnet drops rapidly with distance, roughly as the inverse cube of the distance in the far field of a dipole. Doubling the distance cuts the field to one eighth. A magnet that reads 300,000 µT at its surface falls to a small fraction of that a few centimeters away, which is why the same magnet can be harmless to a gadget a meter away and disruptive to a compass an inch away. Reading a µT value without knowing the distance to the source is meaningless, so note the location whenever you record one. At ten times the distance, the dipole picture predicts a field one thousand times smaller.

MRI in microteslas

A clinical 3 T scanner has a static field of 3,000,000 µT, which is about 60,000 times a typical Earth field of 50 µT. The stray field decreases with distance from the magnet, and facilities mark the area where it exceeds set levels. In documents about safety, values are given in teslas, millitesla or gauss, and sensors used to survey the stray field often read in µT or mT. The conversion lets a technician compare a survey reading, say 2,500 µT, with a limit stated as 2.5 mT, which is the same value. Facilities follow their own protocols. Check the unit symbol on the probe display before logging a value.

Static fields versus alternating fields

A meter that measures a static field responds to magnets and to the Earth. A meter built for power-frequency fields measures the alternating component near wiring and appliances and typically ignores static fields. Both display in µT or mG, so the unit on the screen does not reveal what the instrument is sensing. Before comparing a reading with a guideline, check which kind of field the guideline covers, and what the meter measures. Exposure limits are set by bodies such as ICNIRP and national regulators, and they change over time, so look up the current figure for your frequency instead of relying on a number quoted elsewhere. Averaging time and the direction of the field also affect what a reading means.

From microteslas to teslas and millitesla

Choose microteslas as the source and teslas as the target to divide by 1,000,000. A reading of 45 µT is 0.000045 T, and 2,500 µT is 0.0025 T. In millitesla, 2,500 µT is 2.5 mT, and 45 µT is 0.045 mT. Pick the unit that keeps the number between 1 and 999: µT for the Earth's field and small appliances, mT for magnets and sensors near a source, and T for scanners and laboratory magnets. The conversion is exact, so a round trip returns the original value. Resolution matters too: a sensor that steps in 0.1 µT cannot show a 0.02 µT change, whatever unit the display uses.

Magnitude without direction

The page changes the prefix of a flux density. It does not say whether a field is safe, whether a sensor is calibrated or how the field varies with direction. Vector sensors report three components, and the total magnitude is the square root of the sum of their squares. Use the instrument manual and the applicable guideline for any judgment. The converted number is a magnitude only, with no direction attached.