From the sensor to the formula
Phone apps and Hall sensors output µT, while equations for force on a moving charge, induced voltage or magnetic energy are written with B in teslas. Converting divides by one million. This page does that step, so 10 µT becomes 0.00001 T. The tesla is the SI derived unit of magnetic flux density, equal to one weber per square meter or one kilogram per ampere second squared, as listed in the BIPM SI Brochure. The prefix factor is exact. Use teslas in a formula and prefixes when you present a reading to a person.
A worked example for a coil
Take a flat circular coil of 100 turns and an area of 0.01 square meter in a uniform field of 50 µT. Convert to 0.00005 T before using the induced voltage formula, which for a coil that is flipped through 90 degrees in 0.1 second gives an average voltage of N × B × A divided by the time. That is 100 × 0.00005 × 0.01 / 0.1, or 0.0005 V. Had you inserted 50 instead of 0.00005, the result would be wrong by a factor of one million. Teaching labs use this exercise to show why units need attention. A second variation changes the area: a coil of the same 100 turns and 0.04 square meter gives four times the voltage, 0.002 V, because the area enters the formula directly. Students often get the right pattern and the wrong magnitude when they forget the conversion, and the pattern is what the converter cannot check. Write each quantity with its unit on every line of the calculation, and cancel the units as you go.
Scale of typical fields
Anchors help. The geomagnetic field is about 25 to 65 µT, or 0.000025 to 0.000065 T. A small magnet on a refrigerator has a surface field of the order of millitesla, which is thousands of µT. An MRI scanner at 1.5 T corresponds to 1,500,000 µT, and a 3 T system to 3,000,000 µT. The default 10 µT is 0.00001 T. In teslas, readings from everyday sensors have many leading zeros, which is why the prefix is useful when presenting results.
Hall sensors in projects
Many Hall effect sensor datasheets express sensitivity in mV per mT or mV per gauss, and the output range in mT. Converting your reading to teslas lets you apply the formula for sensor output, V = S × B, in consistent units. For a sensor with a sensitivity of 1.4 mV per mT, a field of 250 µT, which is 0.25 mT, gives an output change of 0.35 mV. The converter helps you move between the two in a few seconds. Add offset and temperature drift to the budget for a real design, because they often exceed small signals. A linear Hall sensor on a 3.3 V supply typically sits at half the supply with no field and moves up or down from there, so the quantity to convert is the change from the zero-field output and not the absolute voltage. Measure the zero-field value with the sensor shielded or far from magnets, store it as a calibration constant, and subtract it before converting the change to teslas.
MRI and strong magnets
Clinical MRI scanners operate at field strengths of 1.5 T and 3 T, with research systems higher. In µT those numbers are millions, which is why safety documents use T and mT. A fringe field limit, such as 0.5 mT for areas accessible to people with pacemakers in many guidance documents, equals 500 µT or 0.0005 T. If a phone magnetometer reads 500 µT near a magnet, you have reached that level. Follow the site rules and the manufacturer guidance for any room that contains a scanner, and do not bring ferromagnetic objects into the scan room. The field does not stop at the door: the stray field spreads around the magnet and falls with distance, and manufacturers publish plots with lines for 0.5 mT and other levels. A site planner reads those lines in mT, a phone app reads in µT, and a facility technician may use gauss, where 0.5 mT is 5 G. Keeping a card with the three values next to each other prevents a slip when the units change between the document and the instrument.
Electric motors and transformers
Designers of motors, inductors and transformers work with flux densities in teslas, often between 0.1 and 2 T in the core material. A leakage field a few centimeters from a transformer might be tens of µT, which is 0.00001 to 0.0001 T. Converting the measured leakage into teslas allows a comparison with the design values. The ratio between the core field and the leakage field shows how effective the shielding or core geometry is, and it can be several orders of magnitude. Wireless chargers, induction cooktops and welding cables are other sources that people measure with a phone or a handheld meter. Their fields have components at frequencies far above the compass range, so a phone magnetometer, which samples at a limited rate, may report a value that is not the true peak. Treat such a conversion as a rough comparison, and use a meter with the proper frequency response for any measurement that matters.
Notation and significant digits
Write 1 × 10^-5 T or 10 µT, not 0.00001 T, in reports where the number might be copied into a spreadsheet. Keep the same number of significant figures as the instrument allows. A phone that resolves 0.1 µT does not justify more than three digits at 50 µT. In software, store values in teslas as floating point numbers and convert at the display layer. That approach avoids repeated conversions that can introduce errors, and it matches the SI form used in physics libraries.
Quick hand checks
Divide by one million, or move the decimal point six places to the left. A value of 65 µT is 0.000065 T, and 1,500,000 µT is 1.5 T. To go back, multiply by one million. If your answer has the wrong number of zeros, count in groups of three through mT: divide by 1,000 to get mT, then by 1,000 again to get T. That mirrors the prefix steps and is a reliable check when numbers get long.
Limits of the page
The converter changes the unit of magnetic flux density and does nothing else. It does not predict the field of a magnet or coil, assess safety around strong magnets or evaluate exposure limits. Those questions require the relevant standards, manufacturer guidance and, where people are involved, qualified professionals. The conversion itself is exact because the prefix micro is defined as 10^-6.