MEASUREMENT & METHODS

Amperes (A): current unit guide

A is the reference unit for electric current.

Measurement basis

An ampere reading already uses this group’s reference scale.

Definition conventions

Prefixes are SI decimal powers, and conversions stay within the current quantity.

Conversion method

Keep A unchanged for the reference. Divide by another current unit’s factor to change the prefix.

Reference equivalent of A

1 A = approximately 1 A.

Recorded scale factors: 1 for A; 1 for A.

Worked example

Known input: 10 A. Reference equivalent: 10 A. The return conversion gives approximately 10 A.

The example preserves current rather than an accumulated charge.

Common reference values

Input (A)Reference equivalent (A)
11
55
1010
2525
5050
100100

Compare one A with other units

Target unitEquivalent of 1 ADefinition guide
Milliamperes (mA)1000Read definition
Microamperes (µA)1000000Read definition
Nanoamperes (nA)1000000000Read definition
Kiloamperes (kA)0.001Read definition
Picoamperes (pA)1000000000000Read definition
Femtoamperes (fA)1000000000000000Read definition

The SI base unit of electric current

The ampere is one of the seven SI base units. Since the revision that took effect on 20 May 2019, it is defined by fixing the elementary charge e at exactly 1.602176634 × 10⁻¹⁹ coulombs, with the coulomb equal to one ampere second. In words, a current of one ampere corresponds to the flow of 1/(1.602176634 × 10⁻¹⁹) elementary charges per second, about 6.24 × 10¹⁸. The symbol is A, and the unit is named for André-Marie Ampère, a French physicist who studied the forces between current-carrying wires in the 1820s. The SI Brochure of the BIPM is the authoritative source for the definition.

The older definition based on force between wires

From 1948 until 2019, the ampere was defined through the force between two long parallel conductors. A constant current that produces a force of 2 × 10⁻⁷ newtons per meter of length between two straight infinite wires of negligible cross-section, placed 1 meter apart in vacuum, was called one ampere. The definition fixed the magnetic constant at 4π × 10⁻⁷ N/A². After 2019, that constant is a measured quantity with a value near 1.25663706 × 10⁻⁶ N/A², and the ampere realization uses single-electron devices and quantum electrical standards. Everyday practice did not change, and the numbers on a meter stayed the same.

Milliamperes, microamperes and kiloamperes

One ampere equals 1,000 mA and 1,000,000 µA. A typical LED indicator draws about 20 mA, or 0.02 A, and a sleeping microcontroller may need only a few microamperes. A USB port supplies 0.5 A in the early standard and up to 3 A or 5 A in newer charging modes, and a laptop charger may deliver 3.25 A at 20 V. Going upward, 1 kA is 1,000 A, which appears in welding, busbars and industrial rectifiers. Lightning strokes are often described as carrying tens of kiloamperes at peak. Because the range is so wide, check the prefix and capitalization before comparing, since mA and MA differ by a factor of one billion.

Current, voltage and power

Current links to the other electrical quantities through Ohm's law, I = V / R, and the power relation P = V × I. A 60 W bulb at 120 V draws 0.5 A, and the same 60 W at 230 V draws 0.261 A. A heater of 1,800 W on 120 V needs 15 A, which is why such a load sits at the edge of a 15 A branch circuit in North America. The resistance of a 12 V, 24 W lamp is 6 Ω and the current is 2 A. An electric kettle of 2,200 W on 230 V draws 9.57 A, while a 2,200 W appliance on a 120 V supply draws 18.3 A, more than a 15 A circuit should carry, which is why high-power appliances are built for the local voltage. North American practice limits continuous loads to 80 percent of the circuit rating, so a 15 A branch circuit supports 12 A, or 1,440 W at 120 V, continuously.

AC current and RMS values

For alternating current, the stated value is usually the RMS, which gives the same heating effect as a direct current of that size. A sinusoidal current of 10 A RMS has a peak of about 14.14 A and a peak-to-peak value of 28.28 A. Clamp meters and multimeters read RMS for sine waves, and true-RMS models also handle distorted waveforms. A conversion between A, mA and kA does not convert between RMS and peak. A load drawing 10 A RMS at 230 V takes 2,300 VA, which is 2,300 W of real power only for a resistive load and 1,840 W at a power factor of 0.8.

Conventional current direction

Conventional current is defined as flowing from the positive terminal through the circuit to the negative one, a convention dating from before the electron was discovered. In metals the electrons move the opposite way. Formulas such as P = V × I and Kirchhoff laws work with either picture as long as signs are kept consistent. Electron drift in a wire is slow: 10 A in a 2.5 mm² copper conductor gives a drift speed of about 0.3 mm/s. A negative reading on an instrument means the current flows opposite to the reference direction chosen for the measurement, and it does not indicate a different amount of charge per second.

Measuring current in practice

An ammeter is connected in series with the load, and it has a very small internal resistance. Connecting a current-measuring input across a voltage source, such as a battery, can blow a fuse or damage the meter. For high currents, a shunt resistor develops a small voltage proportional to the current, for instance 50 mV at 100 A for a 0.5 mΩ shunt, and the meter converts the reading. Clamp meters sense the magnetic field around a conductor without breaking the circuit. Handheld multimeters commonly protect the current jacks with fuses, often rated 10 A on the high-current input and a few hundred milliamperes on the low one.

Amperes are not amp hours

Ah and mAh belong to charge, and they describe how much current can flow over time, not the size of the current at one instant. A 2,000 mAh battery has a capacity of 2 Ah, which is 7,200 C, and delivering 500 mA from it lasts about 4 hours in the ideal case. A figure in amperes alone cannot give the runtime, just as a speed alone cannot give a distance. A current of 3 A flowing for 90 minutes passes 4.5 Ah, which is 16,200 C. A 20 A charger running for 30 minutes delivers 10 Ah.

Reading ratings with care

A rating in amperes on a plug, fuse, wire or switch is set by standards and test conditions that include temperature, duration and the type of load. A fuse rated at 13 A may blow at a higher current after some delay, and a cable rating depends on the installation method. Converting 13 A to 13,000 mA keeps the same limit, but it gives no information about whether a particular device can be used safely. UK plug fuses are sold as 3 A, 5 A and 13 A, chosen to suit the appliance. In a meter reading, 0.250 A, 250 mA and 250,000 µA are the same current.

Precision and checking

  • Retain measured current precision.
  • Keep A separate from Ah.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →