Where nanoamperes show up

Nanoamperes describe currents that are small even by electronics standards. A photodiode in dim light, the dark current of an image sensor pixel, the leakage through a closed analog switch and the standby draw of a real-time clock chip are all quoted in nA. Biosensors and electrochemical cells, such as those in test strips, often work between nA and µA. Data sheets list these figures next to supply currents in mA, so a design review has to put them in a single unit. This page converts from amperes to nanoamperes and, with the dropdowns reversed, back again. Hearing instruments and implantable electronics also specify quiescent currents in this range, so a nanoampere figure is often the headline number on a data sheet. Electrochemical gas sensors and pH electrodes also produce signals in the nA to µA range, depending on concentration.

Nine decimal places and the default

Nano stands for 10^-9, so 1 A equals 1,000,000,000 nA, a billion. The default 10 A is 10^10 nA, written out as 10,000,000,000. Small inputs show the practical use: 0.0000002 A is 200 nA, and 2.5 × 10^-7 A is 250 nA. The conversion is exact, with no rounding. Because the factor is nine decimal places, it is easier to do the conversion in three steps of three, from amperes to milliamperes, then microamperes, then nanoamperes. Checking the result in two steps catches a misplaced zero before the figure goes into a design document. A simple test of your own work is to confirm that 1,000 nA turns into 1 µA when you convert in either direction.

Where the nanoampere sits on a multimeter

Most handheld multimeters stop at the microampere or milliampere range, so a nanoampere figure usually comes from a datasheet or a bench source meter. A part that lists 300 nA of input bias current is 0.3 µA, or 0.0003 mA, and a reading of 0.0003 mA on a handheld meter is a sign that the display is near its resolution limit. A 10 nA standby current in a sleeping sensor board is 0.00001 mA. Converting up to µA or mA tells you whether a standard meter can see the value at all, or whether a source meter or picoammeter is needed. Check the accuracy table of the meter for that range before trusting the last digit of any converted figure.

Standby currents and battery life

Ultra-low-power chips specify standby currents in the tens to hundreds of nanoamperes. A device that draws 500 nA from a 220 mAh coin cell would run for 220 mAh divided by 0.0005 mA, which is 440,000 hours, about 50 years, an ideal figure that is not reachable because the battery self-discharges and loses capacity over a few years. This is why the self-discharge of the battery and the leakage of the board often dominate at this level. Convert any ampere reading from a source-measure unit to nA to compare directly with the data sheet figure. A figure of 500 nA is also 0.5 µA and 0.0005 mA, and which of the three the data sheet uses depends on the maker.

Photodiodes and dark current

A silicon photodiode produces a current roughly proportional to the light falling on it. Typical sensitivity is about 0.5 A per watt at the peak wavelength, so a light power of 100 nW would produce about 50 nA. Dark current, the current with no light, is typically in the pA to nA range and rises with temperature. A reading of 2 × 10^-9 A is 2 nA, and comparing it with the dark current in the data sheet tells you whether the signal is above the noise. The converter handles the units. The physics of the sensor is outside its scope. If the signal is 50 nA and the dark current 2 nA, the dark current is 4 percent of the signal, a ratio that is easy to see once both are in nA.

Moving between nano, pico and micro

The prefixes in the converter form a ladder of factors of 1,000. A nanoampere is 1,000 pA, 0.001 µA and 10^-6 mA. A value of 3.3 µA is 3,300 nA. A value of 0.5 nA is 500 pA. A common error is skipping a rung, for example treating a microampere as 100 nanoamperes. When in doubt, use the page twice: once to reach the unit you trust, once to reach the one you need. For a record of readings from a picoammeter, keeping the raw values in their native unit and adding a converted column makes later review easier. For example, 4,700 pA is 4.7 nA and 0.0047 µA, three forms of one value.

Reading very small results

When converting from nA back to amperes, the numbers have many zeros. A leakage of 250 nA is 0.00000025 A, or 2.5 × 10^-7 A. Spreadsheets switch to exponent notation by themselves, and a copy of the cell into text can lose digits. Keep the value in scientific notation in reports and quote the unit explicitly. When a result appears to be exactly zero, check the display format first. A cell formatted with two decimals will show 0.00 for any current below 5 mA, which hides the whole range of interest for nanoampere work.

Example: a leakage budget on a board

A board has four parts, each leaking 12 nA from the supply while idle, plus a regulator with a quiescent current of 0.35 µA. The four parts add up to 48 nA, and the regulator is 350 nA, so the total is 398 nA, or 0.000000398 A. The regulator accounts for 88 percent of the total, so changing the parts would barely help. Seeing that requires one unit, and the converter turns the regulator figure from µA into nA for the sum. The same method scales to any budget and reveals the dominant term, which is where design effort should go.

What the nanoampere figure leaves out

The page changes the unit of a current you already know. It does not measure leakage, estimate a sensor signal, or judge whether a component meets a specification. As the assumptions state, it does not calculate installation limits, equipment ratings, protection, material response or compliance. For decisions about device performance or safety, use the manufacturer data and the applicable standards. The converted value is the same current written with the prefix nano.