Seven units from femtoamperes to kiloamperes
Electric current in practice ranges from nearly undetectable leakage to lightning-scale surges, and this topic covers seven units: amperes, milliamperes, microamperes, nanoamperes, picoamperes, femtoamperes and kiloamperes. The 43 pages include the Electric current converter, which handles any pair, and direct pages such as Amperes to Milliamperes converter, Milliamperes to Amperes converter, Microamperes to Nanoamperes converter, Picoamperes to Amperes converter and Kiloamperes to Amperes converter. Because every step is a factor of 1,000, conversions are simple powers of ten, and the main risk is counting the steps correctly.
The ampere and its definition
The ampere is the SI base unit of electric current, named after André-Marie Ampère. Since the 2019 redefinition of the SI, it is defined by fixing the elementary charge at exactly 1.602176634 × 10^-19 coulombs, so that one ampere corresponds to the flow of 1/(1.602176634 × 10^-19) elementary charges per second, about 6.24 × 10^18 per second. One ampere equals one coulomb per second. Earlier definitions used the force between parallel wires, which is why the ampere was linked to the magnetic constant. The BIPM SI Brochure gives the current definition. The conversions in this topic follow from that definition and the decimal prefixes.
The prefix ladder
One ampere is 1,000 milliamperes, and one milliampere is 1,000 microamperes. A microampere is 1,000 nanoamperes, a nanoampere 1,000 picoamperes and a picoampere 1,000 femtoamperes. A kiloampere is 1,000 amperes. So 0.5 A equals 500 mA or 500,000 µA, and 30 pA equals 0.03 nA or 30,000 fA. Moving across the ladder shifts the decimal point three places per step, and a conversion of several steps shifts it by a multiple of three. The Amperes to Picoamperes converter is a four-step shift of twelve places. Writing in scientific notation, 2.5 × 10^-3 A for 2.5 mA, makes the shift transparent.
Typical currents
A feel for magnitudes catches mistakes. A small LED indicator runs at around 2 to 20 mA. A smartphone charger supplies 1 to 3 A or more, and a USB port provides 0.5 to 3 A depending on the standard. A household circuit breaker is commonly rated 15 or 20 amperes in North America. An electric vehicle fast charger delivers hundreds of amperes. Lightning strokes carry currents of tens of kiloamperes. At the small end, sensor bias currents are in microamperes, op amp input bias currents in nanoamperes to picoamperes, and patch-clamp recordings of single ion channels in picoamperes. Photodiode dark currents can reach femtoamperes in high-end devices.
Battery capacity and current
Battery capacity is quoted in amp-hours or milliamp-hours, which is current multiplied by time. A 3,000 mAh battery can in principle supply 3 A for one hour or 300 mA for ten hours, though real capacity depends on temperature, discharge rate and age. A device drawing 15 mA from a 220 mAh coin cell would run for about 14.7 hours by the simple ratio. Converting a device's draw from µA to mA before dividing is a common step: a sensor that sleeps at 5 µA is 0.005 mA, and it would take 44,000 hours at that rate to drain the same cell. The ratio ignores self-discharge and cutoff voltage. Pulsed loads complicate the picture further. A wireless sensor that sleeps at 5 µA but transmits for 20 ms at 30 mA once a minute averages about 5 µA plus 30 mA times 20/60,000, which is 10 µA, for a total near 15 µA. Averaging the duty cycle in consistent units is the step where a prefix slip most often creeps in, so convert everything to amperes or microamperes before combining.
Wires, ratings and safety
The current a conductor can carry depends on its cross section, insulation, ambient temperature and installation conditions, and is set by electrical codes and wire manufacturer tables. A converter cannot tell you that. It is worth knowing that current, not voltage alone, is the main factor in electric shock: currents of a few milliamperes through the body are perceptible, and tens of milliamperes can be dangerous. Ground fault protection devices trip at around 5 to 30 milliamperes for that reason. Never use a number from a converter to decide whether a circuit is safe to touch. Follow electrical codes and let qualified people do mains wiring.
Current in electronics datasheets
Datasheets mix units freely. A microcontroller may list active current in mA and sleep current in µA, and a regulator may list quiescent current in µA and maximum output in A. Reading them together requires conversion to one unit. Leakage specifications, such as reverse leakage of a diode at 100 nA, need to be compared with other currents in the same circuit, and power estimates multiply current by voltage: 20 mA at 3.3 V is 66 mW. A signal at 50 µA through 100 kilohms drops 5 V. Moving values into base amperes before applying formulas reduces the chance of a prefix slipping into the result.
Converting milliamps, microamps and kiloamps
Convert 250 mA: that is 0.25 A, 250,000 µA and 2.5 × 10^8 nA. Convert 4.7 µA: that is 4,700 nA, 4.7 × 10^6 pA and 0.0047 mA. Convert 12 kA: that is 12,000 A or 1.2 × 10^7 mA. Convert 800 fA: that is 0.8 pA, 8 × 10^-4 nA and 8 × 10^-13 A. All are exact power-of-ten shifts. One check is to convert back and see whether you land on the starting value. Another is to compare with a typical magnitude: a result that says a phone charger delivers 2,000,000 µA is correct but, written in amperes, is a more readable 2 A.
Common mistakes and scope
Typical errors include confusing mA with µA, which are 1,000 times apart, reading the unit symbol A as area or amp-hours, and treating milliamp-hours as a current. Capital letters matter in some prefixes: in current, kA is kiloampere and the symbol for milli is lowercase m. Alternating current figures can be peak, peak-to-peak or RMS, and a converter does not know which, so state it. These pages convert units for a stated current and do not size wires, estimate battery life, or assess safety. Use proper design rules and manufacturer ratings for real circuits. For alternating current, a 230 V mains appliance drawing 8.7 A RMS has a peak current of about 12.3 A, since peak equals RMS times the square root of two for a sinusoid. Meters and nameplates quote RMS, while oscilloscopes display peaks, so the same circuit can appear with two values that differ by a factor of 1.414. Say which one a number refers to whenever you pass it on.
Frequently asked questions
- How many microamperes are in an ampere?
- One ampere is 1,000,000 microamperes.
- Is milliamp-hour a unit of current?
- No. It is a unit of charge, current multiplied by time, used to rate batteries.
- How is the ampere defined today?
- Since 2019 it is defined by fixing the elementary charge at exactly 1.602176634 × 10^-19 coulombs, with the second as the time unit.
- What current is dangerous to people?
- Even tens of milliamperes through the body can be dangerous. Follow electrical safety rules and use qualified electricians for mains work.