Active current versus sleep current

A battery-powered device lives at two very different current levels. While it is measuring or transmitting, it may draw several milliamperes. While it sleeps, which is most of the time, it may draw only a few hundred nanoamperes. Datasheets list the active figure in mA and the sleep figure in nA, and a battery-life estimate has to put them in one unit. This page converts from milliamperes to nanoamperes by multiplying by 1,000,000. The default input of 10 mA gives 10,000,000 nA. Going the other way, 2,500 nA is 0.0025 mA. The six-power jump hides a trap, because the sleep number looks larger than the active one when written in nA. A designer who reads 2,500 next to 12 without noticing the units can reach the wrong conclusion about which state dominates the energy budget.

The factor explained

One ampere is 1,000 mA and also 1,000,000,000 nA, since nano means 10⁻⁹. Therefore one milliampere is 1,000,000,000 divided by 1,000, or 1,000,000 nA. The formula on the page is nA = mA × 1,000,000. The factor is exact, as it follows from the SI prefixes defined by the BIPM. The ampere is the base unit, defined since 2019 through the fixed value of the elementary charge, 1.602176634 × 10⁻¹⁹ coulomb. One nanoampere then corresponds to about 6.24 billion elementary charges per second, a tiny flow in everyday terms but a measurable one for electrometers and picoammeters. The default conversion of 10 mA to 10,000,000 nA follows by simple multiplication. Entering 0.0025 mA returns 2,500 nA, and entering 2,500 nA returns 0.0025 mA, so the conversion round-trips cleanly.

A coin cell lifetime example

A CR2032 coin cell is commonly rated at about 225 mAh, though the usable capacity depends on the load and temperature. Suppose a sensor sleeps at 2,500 nA, which is 0.0025 mA. Dividing 225 mAh by 0.0025 mA gives 90,000 hours, or about 10.3 years, for the sleeping current alone. If the sensor wakes briefly and draws 4 mA, which is 4,000,000 nA, the average current rises. With a duty cycle of 0.1 percent, the active contribution is 4 mA times 0.001, which is 0.004 mA. Adding the sleep current gives 0.0065 mA, and the life drops to 225 divided by 0.0065, about 34,600 hours or 3.95 years. These numbers are illustrative. Self-discharge, pulse current limits and temperature all shorten real battery life, and the datasheet of the specific cell should be consulted.

Currents that live in nanoamperes

Many physical effects produce currents of nanoamperes. A reverse-biased silicon photodiode in dim light generates photocurrents of this size, and the leakage current of a capacitor or a transistor in the off state often falls in the nanoampere range. Microcontrollers advertise deep-sleep modes that draw a few hundred nanoamperes. Electrochemical sensors, such as those that measure glucose or dissolved oxygen, output currents in nanoamperes to microamperes. Pulse oximeters and radiation detectors work at similar levels. The ability to measure these needs special instruments, since a general-purpose multimeter on its milliampere range cannot resolve 2,500 nA. A reading of 0.0025 mA on a meter with a resolution of 0.01 mA would show as zero. The page does not help with the measurement itself, but it makes the conversion between the datasheet and the instrument range straightforward.

Reading specifications across units

Datasheets are not consistent about units, and a single table may list typical current as 1.2 mA in one row and 800 nA in another. Putting everything into nanoamperes lets you compare them at a glance: 1.2 mA is 1,200,000 nA, which is 1,500 times larger than 800 nA. Alternatively, put everything into milliamperes, and 800 nA becomes 0.0008 mA. Which unit to use depends on the size of the numbers you most care about, and for sleep-current analysis nanoamperes are usually the more readable choice. The common mistake is to compare numbers without checking their units. A table entry reading 5 in a column headed µA is a thousand times larger than a 5 in a column headed nA, and both could appear on the same page of a datasheet. Add the unit next to every figure when you copy it.

4 to 20 mA loops and process signals

Industrial instruments communicate over a current loop where 4 mA represents the bottom of the range and 20 mA the top, so the signal is a current between those values. In nanoamperes that is a range from 4,000,000 nA to 20,000,000 nA. Nobody uses nanoamperes for these loops, and the conversion here serves to compare them with sensors that work at much lower levels. The 4 mA floor is intended to power the transmitter and to distinguish a live zero from a broken wire. Currents below about 3.6 mA are often used by devices to signal faults, following common practice described in the NAMUR recommendation. A reading of 0 mA means an open circuit. The page treats these as plain currents and applies the same factor to all of them.

Leakage and the limits of measurement

At nanoampere levels, stray paths become important. Dirt, flux residue and humidity on a printed circuit board can create leakage paths with resistances of gigaohms, which at a few volts carry nanoamperes. A 3 V supply across 1 GΩ drives 3 nA, a current that can dominate the sleep budget of a sensitive design. Cleaning the board, using guard rings and choosing components with low leakage are the usual remedies. The unit conversion is trivial, but it is a reminder that currents of this size are affected by the environment as much as by the design. When you compare a calculated sleep current with a measured one, expect the measurement to be higher if the board has leakage or if the instrument itself adds a burden voltage. The page offers the conversion without any model of these effects.

Prefix pitfalls

The unit symbols mA, µA and nA differ by one letter, and a typing error can shift the value by a factor of 1,000. A lowercase n is nano, a lowercase m is milli, and a capital M would be mega, which is not used for currents of this size. The letter u is often used in plain text for micro, which can be mistaken for n in handwriting. Convert from milliamperes to nanoamperes in two steps if you want to check: mA to µA multiplies by 1,000, and µA to nA multiplies by 1,000 again. The page uses the single factor of 1,000,000. If your result seems a thousand times too small, you may have stopped after the first step. If it seems a thousand times too large, a step was applied twice.

Other units available in the menus

The menus include amperes, microamperes, picoamperes, femtoamperes and kiloamperes besides milliamperes and nanoamperes. A current of 10 mA is 0.01 A, 10,000 µA, 10,000,000 nA, 10,000,000,000 pA and 10 trillion fA. The picoampere and femtoampere units appear in electrometry and in semiconductor leakage specifications, where a single transistor may leak at levels below a picoampere. If you need a conversion to one of those, select the unit in the To menu. The factor is always a power of ten, and the number of steps in the prefix ladder determines the exponent. Counting steps, three per prefix, gives a quick check on the displayed result.

A duty-cycled budget in both units

An average current is built from the time spent in each state. Take an illustrative wireless node that, in each hour, transmits for 0.2 s at 18 mA, listens for 0.5 s at 6 mA and sleeps for the remaining 3,599.3 s at 0.0025 mA, which is 2,500 nA. The charge per hour in milliampere seconds is 3.6 plus 3.0 plus 8.998, a total of about 15.598. Dividing by 3,600 seconds gives an average of 0.0043328 mA, or 4,332.8 nA. A 225 mAh cell would last about 51,900 hours at that average, roughly 5.9 years before self-discharge and other limits shorten it. Notice that the sleep current contributes more than half of the charge even though it is thousands of times smaller than the transmit current, because the node sleeps almost all the time. Working in nanoamperes for the sleep state and milliamperes for the active states keeps the numbers readable, and the converter links the two.

Photodiodes and transimpedance

A photodiode produces a current proportional to the light falling on it, and that current is often only a few nanoamperes. A transimpedance amplifier turns it into a voltage by passing it through a feedback resistor, with the output equal to the current times the resistance. A photocurrent of 5 nA through a 1 MΩ resistor gives 5 mV, and through a 100 MΩ resistor gives 0.5 V. The value 5 nA is 0.000005 mA, which is why datasheets for the amplifier input bias current, quoted in picoamperes or nanoamperes, are important. Input bias current of the amplifier can be as large as the signal itself, and leakage on the board adds to it. When designing such a circuit, convert all currents into one unit before comparing them. The page does this for the milliampere to nanoampere range, and the rest of the design depends on component selection and layout.

Limits of the nA conversion

The page converts the unit of a current. It does not estimate battery life, predict leakage, size components or check that a device meets a specification. The assumptions on the page note that it does not calculate installation limits, equipment ratings, protection, material response or compliance. The factors follow the SI prefix definitions in the BIPM SI Brochure and in NIST SP 811. The battery example above is an illustration of how the converted values are used, and any real design needs data from the cell manufacturer and measurements on the device.