Measurement basis
A current unit expresses a known rate of electric charge flow. Its unit alone does not determine whether a circuit or installation is appropriate.
Definition conventions
Prefixes are SI decimal powers, and conversions stay within the current quantity.
Conversion method
Use the source and target current-scale ratio without deriving a voltage, power or installation result.
Choose the conversion direction
Confirm the current prefix on the original measurement before selecting the target.
What electric current measures
Electric current is the rate at which electric charge flows past a point. Its SI unit is the ampere, symbol A, defined by the relation 1 A = 1 C/s: one ampere is one coulomb of charge per second. The ampere is one of the seven SI base units, named after the French physicist André-Marie Ampère. Since the 2019 redefinition of the SI, the ampere has been defined by fixing the numerical value of the elementary charge e at exactly 1.602176634 × 10⁻¹⁹ coulombs, as set out in the BIPM SI Brochure. Before 2019 the definition rested on the force between two parallel conductors, adopted in 1948. The change left everyday measurements unaffected while making the definition independent of a mechanical setup. The unit is easy to state but hard to picture, since charge carriers move slowly in conductors even when the current is large. What travels quickly is the electromagnetic signal, not the individual carriers.
The scope of this page
This page compares the supported units of electric current and keeps the quantity separate from others. A current unit expresses a known rate of charge flow, and the unit alone does not say whether a circuit or installation is appropriate. The conversions stay within current, using SI decimal prefixes, so they relate amperes to milliamperes, microamperes, kiloamperes and the other supported scales without involving voltage, power or energy. A current of 5 A cannot be turned into watts without knowing the voltage, and it cannot be turned into coulombs without knowing the time. Those are different quantities with their own units, and the page does not derive them. The conversions are therefore among current units only.
Prefixes and the scale of the ampere
SI prefixes are decimal powers, and each current unit differs from the next by a factor of one thousand. A milliampere is 10⁻³ A, a microampere is 10⁻⁶ A, a nanoampere is 10⁻⁹ A and a picoampere is 10⁻¹² A. Going up, a kiloampere is 10³ A and a megaampere is 10⁶ A. So 250 mA is 0.25 A, 47 µA is 0.000047 A, and 1.5 kA is 1,500 A. The correct writing keeps the prefix attached to the symbol A with no space, as in mA. Case matters: mA is milliampere, and MA would be megaampere. Mistyping the case changes the value by a factor of a billion.
Typical magnitudes
Current spans an enormous range in practice. Biological and sensor signals are often in nanoamperes to microamperes. Small indicator LEDs run at a few milliamperes, commonly somewhere around 2 to 20 mA depending on type. A USB 2.0 port is specified to deliver up to 500 mA at 5 V for a standard device, while charging ports and later standards allow more. Household branch circuits in many countries are protected by breakers rated at 10 to 20 amperes, and an electric stove or car charger may draw tens of amperes. Industrial busbars carry thousands of amperes. A lightning stroke can reach peak currents of tens of kiloamperes for a few microseconds. These values show why the prefixes are needed. The numbers are approximate guides that vary by device and region, and a specific rating always comes from the equipment label or specification.
Current, charge and time
Current is defined through charge, and the relation Q = I × t links the two. A steady current of 2 A for 30 minutes moves 2 × 1,800 = 3,600 coulombs. That equals one ampere-hour, because 1 Ah = 3,600 C. Battery capacities quoted in milliampere-hours follow the same relation, so a 3,000 mAh battery holds 3 Ah, which corresponds to 10,800 coulombs. Capacity in mAh is a measure of charge and not of current, even though the unit contains the symbol of the latter. The current is the rate, and the charge is the total. Mixing the two leads to errors in estimating run time, which is charge divided by the average current drawn.
Relation to voltage, resistance and power
Ohm's law links current to voltage and resistance in a simple resistor: I = V / R. A 5 V source across a 1 kilohm resistor produces 5 mA, because 5 / 1,000 = 0.005 A. Electrical power in a circuit is P = V × I, so 5 mA at 5 V dissipates 25 milliwatts. These relations show how the same current can be expressed in different prefixes depending on the circuit. They also explain why this page does not convert current to power: a current needs a voltage before it gives power. Keep the original measurement and its unit, then convert the current alone, with the circuit values used elsewhere in the calculation.
Direct, alternating and the meaning of the number
A current can flow in one direction, as in a battery circuit, or reverse periodically, as in mains power. For alternating current, the stated value is usually the root-mean-square value, which gives the same heating effect as a direct current of that magnitude. A mains circuit described as 10 A rms has a peak current of about 14.1 A for a sinusoidal waveform, since the peak is the rms value times the square root of 2. The ampere conversion on this page does not distinguish these cases, and it treats the entered number as a given amount. Record whether a measurement is steady, rms or peak alongside the number so that it can be interpreted later. For a sine wave the peak-to-peak value is twice the peak, so a quoted 20 A peak-to-peak current has a peak of 10 A and an rms value of about 7.07 A. Reading the wrong one of these changes the answer by a factor of about 1.4 to 2.8.
Direction and the sign convention
By convention, the direction of current is the direction in which positive charge would move, from the positive terminal toward the negative one outside a source. In metal conductors, the charge carriers are electrons, which move the opposite way. The convention goes back to the period before the electron was identified, and circuit analysis still uses it. A negative sign on a current value in a diagram means the actual flow is opposite to the arrow you chose, not that something is wrong. The unit conversions on this page work on the magnitude and keep the sign of the entered value. When recording measurements, note the reference direction so that a sign has a clear meaning.
Measurement practice
An ammeter measures current by being placed in series with the circuit, so that the whole current flows through it. A clamp meter senses the magnetic field around a conductor and avoids breaking the circuit. Each instrument has ranges, resolution and an accuracy specification, and the reading carries that uncertainty. Selecting the wrong range, or connecting an ammeter across a voltage source, can blow a fuse or damage the meter. Large currents and exposed conductors are hazardous, and safety standards, such as IEC 60479 on the effects of current on the human body, address that. A unit page cannot make a measurement safe or valid, and the instruction manual and the relevant electrical codes govern how to take readings. Always start with the highest range on an unknown current, then step down to improve the resolution.
Worked conversions
A few conversions show the factors in use. A current of 1.5 A is 1,500 mA. A reading of 0.8 mA is 800 µA, and 35 µA is 0.035 mA or 0.000035 A. A fault current of 12 kA is 12,000 A. A sensor that draws 40 mA at 3.3 V consumes 0.04 × 3.3 = 0.132 watts, or 132 milliwatts, though that last step uses voltage and so falls outside this page. Going from a larger to a smaller prefix multiplies by 1,000, and going from smaller to larger divides by 1,000. If the result has gained zeros in the wrong direction, the factor was applied backward. A quick sense check is that the same current must be a bigger number in a smaller unit.
Confusions to avoid
Several pairs of terms are easy to mix. Amp and ampere are the same unit, although the standard name is ampere and the symbol is A. Milliamp-hours measure charge, as described above. The symbol mA should not be read as megaampere, and kA is the standard symbol for kiloampere, with a lowercase k. Current is also not the same as current density, which is current per unit area and measured in amperes per square meter. Finally, a rating on a device such as a fuse, a cable or a power supply states a limit for current, not the current that actually flows. A power supply rated for 2 A supplies only what the load draws, up to that limit. Another trap is to treat the current rating on a charger or a battery as the current in use. The number printed on the label is a maximum or a capacity, and the circuit decides what actually flows.
Keeping precision when converting
Prefix conversions between amperes and their multiples are exact, since each step is a power of ten. The risk lies in the digits you keep. A measurement of 0.250 A has three significant figures, and its equivalent 250 mA has the same three. Writing 250.000 mA would imply more precision than the instrument gave. Keep the resolution of the source measurement, and round only when you present the final value. Retain the prefix symbols on every number, since an unlabeled value moved into a circuit record is a common route to a thousandfold error. The page converts between current scales, and the quality of the answer remains tied to the quality of the original reading.
Precision and checking
- Keep the source current measurement resolution.
- Retain prefix symbols rather than copying an unlabeled number.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Amperes (A)
Definition, reference values and linked conversions.
Milliamperes (mA)
Definition, reference values and linked conversions.
Microamperes (µA)
Definition, reference values and linked conversions.
Nanoamperes (nA)
Definition, reference values and linked conversions.
Kiloamperes (kA)
Definition, reference values and linked conversions.
Picoamperes (pA)
Definition, reference values and linked conversions.
Femtoamperes (fA)
Definition, reference values and linked conversions.
Use a working converter
- Electric current converter
- Amperes to Milliamperes converter
- Milliamperes to Amperes converter
- Amperes to Microamperes converter
- Microamperes to Amperes converter
- Amperes to Nanoamperes converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.