Measurement basis
Its reference factor is 10^-15 A.
Definition conventions
Prefixes are SI decimal powers, and conversions stay within the current quantity.
Conversion method
Multiply fA by 10^-15 without rounding the small result early.
Reference equivalent of fA
1 fA = approximately 1e-15 A.
Recorded scale factors: 1e-15 for fA; 1 for A.
Worked example
Known input: 10 fA. Reference equivalent: 1e-14 A. The return conversion gives approximately 10 fA.
The example retains the current quantity.
Common reference values
| Input (fA) | Reference equivalent (A) |
|---|---|
| 1 | 1e-15 |
| 5 | 5e-15 |
| 10 | 1e-14 |
| 25 | 2.5e-14 |
| 50 | 5e-14 |
| 100 | 1e-13 |
Compare one fA with other units
| Target unit | Equivalent of 1 fA | Definition guide |
|---|---|---|
| Amperes (A) | 1e-15 | Read definition |
| Milliamperes (mA) | 1e-12 | Read definition |
| Microamperes (µA) | 1e-9 | Read definition |
| Nanoamperes (nA) | 0.000001 | Read definition |
| Kiloamperes (kA) | 1e-18 | Read definition |
| Picoamperes (pA) | 0.001 | Read definition |
One quadrillionth of an ampere
The femtoampere (fA) is 10⁻¹⁵ of an ampere, so 1 A equals 10¹⁵ fA, and 1 fA equals 0.001 pA, 10⁻⁶ nA or 10⁻¹² mA. The prefix femto was added to the SI in 1964 by the 12th General Conference on Weights and Measures, and it is listed with its symbol f in the SI Brochure. The name is usually traced to the Danish and Norwegian word for fifteen, a reference to the exponent of minus fifteen. An ampere is defined by fixing the elementary charge at exactly 1.602176634 × 10⁻¹⁹ coulomb, so a femtoampere has a precise meaning: a charge flow of one quadrillionth of a coulomb each second.
How many electrons that is
Dividing the current by the elementary charge turns it into a particle count. One femtoampere is 10⁻¹⁵ C/s divided by 1.602176634 × 10⁻¹⁹ C per electron, which is about 6,241.5 electrons per second. A current of 100 fA corresponds to about 624,000 electrons per second, and 1 pA to 6.24 million. By comparison, a 1 A current carries about 6.24 × 10¹⁸ electrons each second. At the femtoampere level, current is a countable stream of charges, and statistical fluctuation, called shot noise, becomes a visible part of any measurement. The relative noise grows as the current gets smaller, which limits how fast a stable reading can be obtained.
Where femtoamperes appear
Currents this small come from leakage and sensing. The off-state leakage of a modern transistor or the gate leakage in a capacitor may be tens of femtoamperes in a lab test, depending on process and temperature. Photodiodes in the dark produce dark currents from femtoamperes to nanoamperes, depending on area and bias. Ion chambers used for radiation monitoring, mass spectrometer detectors such as Faraday cups, and electrochemical sensors have output currents in this range. A pH electrode or a glass microelectrode presents a very high source resistance, so the bias current of the measuring amplifier, often listed in femtoamperes, matters. Data sheets for precision amplifiers advertise input bias currents of a few femtoamperes to show suitability for such sources.
Converting to neighboring units
Because each SI prefix step is a factor of 1,000, moving between units near the femtoampere is a matter of shifting the decimal point. A reading of 2,500 fA is 2.5 pA. A leakage of 0.04 nA is 40 pA, which is 40,000 fA. A bias current of 3 fA equals 0.003 pA and 3 × 10⁻¹⁵ A. In the other direction, 4.7 pA is 4,700 fA. It helps to attach an electron count as a cross-check, since 1 pA, at about 6.24 million electrons per second, should convert to 1,000 fA, and the electron count should scale by the same 1,000. A converter does the same shift, but it is worth knowing the magnitudes.
Ohm's law at tiny currents
The voltage across a resistor is V = I × R, and the numbers show why femtoampere measurement is hard. A current of 100 fA through a 10 GΩ resistor produces only 10⁻¹³ × 10¹⁰ = 1 mV. To read 1 fA with a gain of 10¹² V/A, an electrometer amplifier needs a feedback resistance of 1 TΩ and has to resolve 1 mV out of the signal. Resistors this large have their own thermal noise, which scales with the square root of resistance, and they limit bandwidth when combined with stray capacitance. A feedback of 1 TΩ with 1 pF of capacitance has a time constant of 1 s, so the instrument responds slowly, a trade-off that explains slow settling in such measurements.
What makes the measurement difficult
Measuring femtoamperes requires attention to the setup. Insulation leakage across a dirty printed circuit board or a humid surface can easily exceed the signal. Cables generate triboelectric charge when flexed and piezoelectric charge when stressed, giving spurious currents of picoamperes. Instrument makers use guarded triaxial cabling, low-leakage insulators such as PTFE and sapphire, shielding against electrostatic interference and a stable environment. Even the offset current of the instrument has to be subtracted. Specialized electrometers and source-measure units quote resolution down to 1 fA or below and require warm-up time and careful cabling. A reading in femtoamperes should always be accompanied by the measurement conditions.
Charge accumulation instead of direct reading
When a direct reading is too noisy, experiments integrate current over time. A current of 1 fA flowing for 1 second moves 1 fC, and for 1,000 seconds it moves 1 pC. Integrating on a capacitor of 1 pF, that charge appears as a voltage of 1 V after 1,000 seconds, which is easy to read. This approach underlies charge-sensitive amplifiers for particle detectors and some dark-current tests of image sensors, where a long exposure reveals a very small current as a measurable signal. The relationship Q = I × t makes the unit conversion between fA, fC and seconds simple, and it shows how averaging improves the signal against noise.
Leakage budgets in standby electronics
Femtoampere figures add up when many devices share a supply. A leakage of 10 fA per transistor across one billion transistors sums to 10 µA, since 10⁻¹⁴ A times 10⁹ is 10⁻⁵ A. A coin cell of 220 mAh would take 22,000 hours, about 2.5 years, to discharge at that rate, so such leakage is tolerable in a standby circuit only when it stays near the lab value. Real leakage grows steeply with temperature, often doubling every 10 °C or so, which means a figure measured at 25 °C can be much larger on a hot board. Designers therefore state leakage at a temperature and supply voltage, and a femtoampere value without these conditions is incomplete.
Symbol, case and spacing
The symbol is fA, with a lowercase f for femto and an uppercase A for ampere, and a space separates it from the number. Writing FA or Fa is incorrect, and so is pA mistyped as PA, which could be read as a peta-prefix. Lowercase p means pico and uppercase P means peta, a difference of 27 orders of magnitude. In plain text where the prefix may be confused, spell the unit out as femtoampere. When converting, keep the exponent rather than long strings of zeros, as in 2.5 × 10⁻¹⁵ A, and avoid rounding intermediate values, since the result is usually a small number that should keep its significant digits.
Precision and checking
- Keep source current resolution.
- Retain lowercase f.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Electric current converter
- Femtoamperes to Amperes converter
- Femtoamperes to Milliamperes converter
- Femtoamperes to Microamperes converter
- Femtoamperes to Nanoamperes converter
- Femtoamperes to Kiloamperes converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.