Between the leakage scale and the signal scale

Femtoamperes and nanoamperes describe two neighboring regions of small current. Nanoamperes are the typical scale of photodiode signals under dim light, the tunneling current in a scanning tunneling microscope and the output of a photomultiplier tube. Femtoamperes are the scale of the noise and leakage that a measurement of such signals must beat. A signal of 2 nA measured against a leakage of 200 fA has a ratio of 10,000, a comfortable margin. This converter expresses one in terms of the other: enter a current in fA and read nA. The default of 10 fA converts to 0.00001 nA, or 1e-5 nA. The factor of one millionth is exact, because it is the ratio of the prefixes femto and nano, 1e-15 divided by 1e-9. Having both in the same unit helps in judging signal-to-leakage ratios at a glance.

The million-fold step

From femto to nano is six orders of magnitude, two steps of 1,000. One thousand femtoamperes is one picoampere, and one thousand picoamperes is one nanoampere. So a nanoampere holds a million femtoamperes. The conversion is therefore a division by 1,000,000 when going from fA to nA, and a multiplication by 1,000,000 in the other direction. A current of 250,000 fA is 250 pA and 0.25 nA. A current of 3,000,000 fA is 3 nA. The default 10 fA is a tiny fraction of that. The NIST table of SI decimal prefixes is the source for these definitions. With only two steps of 1,000, the conversion is easy to do mentally, which makes it a useful check on the tool for anyone learning prefixes.

Scanning tunneling microscopy

In scanning tunneling microscopy, a sharp metal tip is held a fraction of a nanometer above a conducting surface, and a small voltage drives a tunneling current between them. Typical setpoints are in the range of tens of picoamperes to a few nanoamperes. That is tens of thousands of fA up to a few million fA, which is roughly a thousand to a few hundred thousand times the 10 fA default. The current depends exponentially on the gap, so a change of a tenth of a nanometer changes it by roughly an order of magnitude, which is why the method can resolve single atoms. Noise of 100 fA on a signal of 100 pA is 0.1 percent of the signal. Expressing the noise and the setpoint in nanoamperes, 0.0001 and 0.1, shows the ratio at a glance. These are broad descriptions, and each instrument has its own working range.

Photodiodes and photomultipliers

A photodiode turns light into current, and in dim conditions the output sits in the nanoampere range. The dark current, which flows with no light, can be in the picoampere or femtoampere range for a good device at room temperature. The ratio between signal and dark current sets the lowest light level the detector can sense. If a signal is 5,000 fA and the dark current is 50 fA, the signal is 100 times the dark current. In nanoamperes those values are 0.005 and 0.00005. Photomultiplier tubes amplify single photons into pulses of many electrons, and their anode currents are often quoted in nanoamperes. The values here are illustrative. The converter lets you place datasheet numbers that use different prefixes onto one scale before computing ratios.

Electrons per second

Because the ampere is tied to the elementary charge, any current corresponds to a rate of charge flow. One nanoampere is about 6.24 billion electrons per second. One femtoampere is about 6,241 per second, so a nanoampere holds a million times more. Ten femtoamperes is about 62,415 electrons per second, which the converter expresses as 0.00001 nA. Seeing 0.00001 nA next to 62,415 electrons per second makes the smallness concrete. It also shows why measurements at this scale are limited by counting statistics. In one second, the 10 fA current delivers only tens of thousands of charges, and the relative fluctuation in that count is about 0.4 percent, which is the reciprocal of the square root of 62,415. The calculation is an idealized estimate for singly charged carriers.

Operational amplifier specifications

Amplifier data sheets list input bias current, the small current flowing into the input pins. General-purpose bipolar amplifiers have bias currents in the range of tens to hundreds of nanoamperes. JFET-input amplifiers are lower, in the picoampere range. Electrometer-grade amplifiers go lower still, down to femtoamperes. A bias current of 250,000 fA is 0.25 nA, which is typical of a low-bias part. Comparing specifications requires one unit, and converting both to nanoamperes or both to femtoamperes avoids mistakes of 1,000 or 1,000,000. A mistake of this size can mean choosing a part whose bias current swamps the signal. The example values are generic. Always check the conditions on the data sheet, since bias current changes with temperature, usually doubling for every 10 °C rise in JFET inputs.

Choosing the prefix for reporting

When reporting a measured current, use the prefix that gives a number between 1 and 999. A current of 0.25 nA is better reported as 250 pA, and 5,000 fA is better reported as 5 pA. The converter is helpful to confirm such changes. The NIST guidance on SI prefixes encourages choosing prefixes to keep the numerical value in a convenient range. Use a single prefix within a table or figure so that the reader can compare values without converting. If a table contains values from 20 fA to 3 nA, choosing pA for the whole column gives values from 0.02 to 3,000, which is workable and consistent. Mixed units in the same column are a frequent cause of misreading.

Direction and prefix slips

The most common error is shifting the decimal by the wrong number of places. Going from fA to nA, the number gets smaller by 10 to the 6th, and a result larger than the input is a sign of a reversed direction. Another error is confusing nA with nF or nAh, which are different quantities. A third is quoting a current without its measurement conditions, such as bandwidth and temperature, which matter at this level. Finally, mixing up pico and nano, a factor of 1,000, is a classic slip. Reading the result back against the ladder of prefixes catches most mistakes. Starting from 10 fA, the result 0.00001 nA has four zeros after the decimal point before the digit one, which fits six places of movement from 10.

Averaging to dig a signal out of noise

Noise can often be reduced by averaging many readings. If random noise is independent from reading to reading, averaging N readings reduces it by the square root of N. Suppose a photodiode signal is 5,000 fA, which is 0.005 nA, and each reading carries 500 fA of random noise, or 0.0005 nA. Averaging 100 readings reduces the noise to 50 fA, or 0.00005 nA, and the signal-to-noise ratio improves from 10 to 100. The price is time, since 100 readings take 100 times as long. Averaging does not help with a steady offset or drift, such as slow changes in leakage with temperature, so the baseline must be measured too. Putting the signal and noise in the same unit, whether fA or nA, is the first step in any such calculation.

Ion beams and Faraday cups

A Faraday cup collects a beam of charged particles and passes the charge to an electrometer, so the beam current can be read directly. A beam current of 2.5 nA of singly charged ions corresponds to 2.5e-9 divided by 1.602e-19, which is about 1.56 times 10 to the 10th ions per second. A beam of 250 fA, a ten-thousandth of that, delivers about 1.56 million ions per second. In mass spectrometry, detectors for the smallest ion signals work in the femtoampere range, and the converter makes it easy to relate the two. The numbers above are idealized and assume that every ion carries exactly one elementary charge, which fails for multiply charged ions or when secondary electrons leave the cup.

Biosensors and wearable devices

Electrochemical sensors, such as the amperometric sensors in some wearable glucose monitors, produce currents in the nanoampere range. The sensor reacts with its target, an electron transfer takes place, and the resulting current is proportional to the concentration. The electronics must resolve changes of a small fraction of a nanoampere, which is picoampere and sometimes femtoampere resolution, while rejecting leakage and drift. A design specification might call for noise below 100 fA, or 0.0001 nA, on a 5 nA signal, a ratio of 50,000 to one. Expressing the signal and noise in one unit makes this requirement clear to both chemists and electrical engineers, who often use different prefixes by habit. The values here are illustrative of the scale and do not describe any particular device.

A conversion table for a spreadsheet

When a column of measurements runs from tens of femtoamperes to hundreds of picoamperes, converting the whole column to nanoamperes gives a consistent set of small decimals that can be plotted and compared. A reading of 20 fA becomes 0.00002 nA. A reading of 800 fA becomes 0.0008 nA. A reading of 12,000 fA, which is 12 pA, becomes 0.012 nA, and 450,000 fA, which is 450 pA, becomes 0.45 nA. The same values in picoamperes would be 0.02, 0.8, 12 and 450, which are easier to read, so nanoamperes make sense mainly when the table also contains larger currents that need the unit. Whichever unit you choose, record it in the column header, and keep the original femtoampere values in a separate column in case a conversion needs to be audited.

Limits of the fA to nA page

This page converts a current from femtoamperes to nanoamperes. It does not measure current, estimate noise, check a circuit or decide whether any equipment is within its ratings, protection or compliance requirements. The page says explicitly that it expresses the same physical quantity in a compatible unit. Treat the output as a change of units only. Decisions about instruments, circuits and safety need the relevant documentation, a measurement, and in some cases a qualified engineer.