Measurement basis
One pA corresponds to 10^-12 A.
Definition conventions
Prefixes are SI decimal powers, and conversions stay within the current quantity.
Conversion method
Multiply pA by 10^-12 for amperes.
Reference equivalent of pA
1 pA = approximately 1e-12 A.
Recorded scale factors: 1e-12 for pA; 1 for A.
Worked example
Known input: 10 pA. Reference equivalent: 1e-11 A. The return conversion gives approximately 10 pA.
The small reference result preserves current.
Common reference values
| Input (pA) | Reference equivalent (A) |
|---|---|
| 1 | 1e-12 |
| 5 | 5e-12 |
| 10 | 1e-11 |
| 25 | 2.5e-11 |
| 50 | 5e-11 |
| 100 | 1e-10 |
Compare one pA with other units
| Target unit | Equivalent of 1 pA | Definition guide |
|---|---|---|
| Amperes (A) | 1e-12 | Read definition |
| Milliamperes (mA) | 1e-9 | Read definition |
| Microamperes (µA) | 0.000001 | Read definition |
| Nanoamperes (nA) | 0.001 | Read definition |
| Kiloamperes (kA) | 1e-15 | Read definition |
| Femtoamperes (fA) | 1000 | Read definition |
A trillionth of an ampere in electrons per second
The picoampere, symbol pA, is 10⁻¹² of an ampere. Since the 2019 revision of the SI, the ampere is defined by fixing the elementary charge at exactly 1.602176634 × 10⁻¹⁹ coulomb, so a current is literally a count of charges passing a point each second. One picoampere is 6.2415 million elementary charges per second. That sounds large, but it is a tiny flow compared with a 1 A load, which carries about 6.24 × 10¹⁸ charges each second. The unit lives in the territory of electrometers, ion channels and leakage, where currents are small enough that single events matter. Seeing the electron count helps explain why such currents are noisy and why they need shielding and slow averaging to measure well.
Patch clamp recordings in cells
In neuroscience, the picoampere is the working unit of the patch clamp technique developed by Erwin Neher and Bert Sakmann, who received the 1991 Nobel Prize in Physiology or Medicine. A single ion channel in a cell membrane passes a current of a few picoamperes when it opens, and the recording switches between closed and open levels in steps of that size. Whole-cell recordings run higher, often in the hundreds of picoamperes to nanoamperes. The amplifier has to resolve changes of a fraction of a picoampere against a background of thermal noise, which is why recordings use a gigaohm seal between pipette and membrane. A 5 pA step at a 100 mV holding potential implies a channel conductance of 50 pS.
Leakage and bias currents in electronics
Circuit designers meet picoamperes as leakage. Op-amps with JFET or CMOS inputs list input bias currents from a fraction of a picoampere to tens of picoamperes, and bipolar inputs draw nanoamperes or more. Photodiodes in the dark carry a reverse current that can be in the picoampere range, and a sample-and-hold circuit loses voltage as its capacitor leaks. A 100 pA leakage on a 1 nF hold capacitor changes the voltage at 0.1 V per second, from dV/dt = I/C. Printed circuit boards add their own paths, since contamination on a board surface can leak more current than a well-chosen input stage. High-impedance designs use guard rings and clean, dry boards for exactly this reason.
Shot noise as a physical limit
A current made of discrete charges is never perfectly smooth. Shot noise has a spectral density of the square root of 2qI per hertz, where q is the elementary charge. For 1 pA, that is about 0.566 fA/√Hz, or 566 aA/√Hz, and in a 1 kHz bandwidth the rms noise is about 17.9 fA, which is 1.8 percent of the signal. At 1 nA the fractional noise falls by a factor of about 30. This is why low-current instruments average for long periods and restrict bandwidth. A reading of 1.000 pA with ten digits of display means nothing if the noise floor of the electrometer is several femtoamperes, and the stated resolution in the instrument manual should guide how many digits you keep. Picoammeters and electrometers from several makers resolve down to the femtoampere range, which is the reason a 1 pA reading can be trusted to a few digits on a good instrument and to none on a general-purpose multimeter, whose lowest range is usually in the hundreds of nanoamperes.
Mass spectrometry and particle detection
Mass spectrometers and electron microscopes detect ion and electron beams as currents, often through a Faraday cup that collects the charge and feeds it to an electrometer. A beam of 10 pA delivers 6.24 × 10⁷ singly charged ions each second. Isotope ratio instruments measure currents from picoamperes up to nanoamperes with resistors of 10¹¹ to 10¹³ ohms in the feedback path, so a 1 pA current across a 10¹¹ Ω resistor produces 0.1 V. Scanning electron microscopes quote probe current in picoamperes, and a few pA to a few nA are typical ranges. A smaller current gives less signal and better resolution, so the unit reflects a choice about image quality as well as a measurement. Doubling the probe current doubles the number of electrons arriving per second, which cuts the relative shot noise in each pixel by a factor of about 1.41.
Ladder of neighboring current units
The Computandum current converters list the steps in either direction. Amperes to Picoamperes multiplies by 1 × 10¹², Milliamperes to Picoamperes by 10⁹, Microamperes to Picoamperes by 10⁶ and Nanoamperes to Picoamperes by 1,000. Going down, Picoamperes to Femtoamperes multiplies by 1,000, and Picoamperes to Nanoamperes multiplies by 0.001. A 250 pA reading is therefore 0.25 nA, 0.00025 µA and 250,000 fA. Because the factors are powers of ten, a conversion only moves the decimal point, and a mistake of three places is the typical error. Writing each value with its unit and keeping the same instrument range avoids the slip in a table.
Current, charge and time
One ampere is one coulomb per second, so a picoampere is one picocoulomb per second. A constant 5 pA flowing for 10 s transfers 50 pC, which is 3.12 × 10⁸ elementary charges. Integrating a small current over time is how charge-based instruments produce their readings. A 1 nF capacitor charged by 1 pA takes 1,000 seconds to reach 1 V, since V = It/C, which is a drift of 1 mV per second. The relation is used in reverse for measuring leakage, where the voltage drift on a known capacitor gives the current. Keeping amount and rate apart prevents mix-ups between picoamperes and picocoulombs, which look alike in a datasheet but describe different things.
Display digits versus measurement quality
A picoampere figure carries only the digits the instrument can support. Converting 2.37 pA to amperes gives 2.37 × 10⁻¹² A, which looks precise but has the same three significant digits as the original and no more. Calibration of electrometers at the picoampere level is hard, and uncertainties of one percent or more are common. Temperature, humidity, cable movement and light on a sample all change the result. Triboelectric noise from a flexing coaxial cable can add picoamperes of its own, so low-noise cable is used. Record the range, filter setting and temperature along with the reading. Cleaning agents, flux residue and even finger oils on an insulator can create leakage paths of a few picoamperes at modest voltage, so handling rules are part of the measurement method. The symbol is pA, with a lowercase p and capital A, and PA in a capital form means something else entirely.
Precision and checking
- Retain measured current resolution.
- Keep the pico prefix.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Electric current converter
- Picoamperes to Amperes converter
- Picoamperes to Milliamperes converter
- Picoamperes to Microamperes converter
- Picoamperes to Nanoamperes converter
- Picoamperes to Kiloamperes converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.