Setting a leakage next to a working current
Circuit designers often need to know whether a leakage is negligible compared with the current a part is meant to carry. An indicator LED runs at 2 to 20 mA, a sensor board at a few milliamperes and a small motor at tens or hundreds. A leakage of 50 pA can look alarming when you read it in a data sheet and trivial when you see it in the same unit as the load. This page multiplies picoamperes by 10^-9 to give milliamperes. The result is almost always a tiny number, shown in scientific notation, and the comparison with the working current makes the scale clear at once. A leakage that is a billionth of the load rarely needs attention, while one that approaches a thousandth of it may deserve a closer look, depending on the accuracy the circuit has to deliver.
A billion picoamperes make one milliampere
Pico is 10^-12 and milli is 10^-3, so one milliampere holds 10^9 picoamperes, a billion, as defined in the SI Brochure (BIPM) and listed in NIST SP 811. The formula is mA = pA × 10^-9. Move the decimal point nine places to the left: 2,000,000,000 pA is 2 mA, and 500 pA is 5 × 10^-7 mA. A value of 750,000 pA is 0.00075 mA. Reversing the direction, 0.5 mA is 500,000,000 pA. If you need an intermediate check, go through nanoamperes: 500 pA is 0.5 nA, and 1 nA is 10^-6 mA, which gives 5 × 10^-7 mA again. Both routes agree for every input.
Why 10 pA appears as 9.999999999999999e-9
With 10 pA the page returns about 1e-8 mA, which means 1 × 10^-8 mA, or 0.00000001 mA. The display may show a number like 9.999999999999999e-9, a floating-point artifact of the calculation. The intended value is 1e-8, and rounding to a few significant digits is correct because the input has only two. Entering 1,000 pA, which is 1 nA, gives 1e-6 mA, and 1,000,000 pA gives 1e-3 mA. If you copy the value into a spreadsheet, type 1E-8 or round it first, so that later comparisons are not thrown off by the last digit. A tolerance in comparisons is better than exact equality.
LED current against its leakage
A red indicator LED run from a 3.3 V supply through a 330 Ω resistor passes about (3.3 − 1.9) ÷ 330 = 4.2 mA, assuming a forward voltage near 1.9 V, an illustrative figure. A reverse leakage of 1,000 pA through the same LED is 1 × 10^-6 mA, which is about four millionths of that current. The comparison explains why leakage can be ignored for indicator work and still matter in a precision input stage. For a dimmable LED at its lowest setting of 0.05 mA, a leakage of 100 nA, or 100,000 pA, is 0.0001 mA, which is 0.2 percent of the current and still small.
Battery self-discharge and parasitic draw
Parasitic drains matter in storage and in long deployments. A leakage of 1,000,000 pA is 0.001 mA, which is 1 µA. Over a year of 8,760 hours, that drains 8.76 mAh, a small part of a 2,000 mAh AA cell, about 0.4 percent. A drain of 10 µA would take 87.6 mAh a year, close to 4.4 percent of the same cell. In contrast, picoampere-level leakage of 10 pA drains less than a hundredth of a microamp-hour per year. These examples show why only the microampere and larger paths matter for batteries, and picoamperes matter for sensing. The values are illustrative and depend on temperature and the battery chemistry.
Input protection and ESD diodes
Protection diodes on an input pin are reverse biased in normal use, and their leakage appears in data sheets as a figure such as 1 nA, 100 pA or less at a given voltage and temperature. At 125 °C, the leakage can be several hundred times larger. A 1 nA leakage is 1,000 pA and 1e-6 mA. When this current flows through a 10 MΩ source resistor, it produces 10 mV of error. Converting units helps you see how a hot environment turns a negligible current into a measurable one. The page leaves the diode model to you and the data sheet, which lists the worst case at the temperature you need. For a circuit that runs in an engine bay or a sealed outdoor box, use the hot figure, since the room-temperature value can understate the leakage by two orders of magnitude and the error then shows up only in summer.
Reading meter ranges
A bench meter on its 2 mA range may resolve 1 µA, which is 1,000,000 pA. Anything below that, such as a leakage of 500,000 pA, does not register at all and the display shows zero. To see smaller currents you move to a µA or nA range, or use a picoammeter. The range sets the resolution. When someone says a circuit draws zero current, the correct statement is that it draws less than the meter can resolve on that range. Converting that resolution to picoamperes shows how much room remains: 1 µA of resolution can hide a leakage of nearly a million picoamperes.
Choosing mA, µA or pA in documents
Pick the unit so the number lands between 1 and 1,000. Active-mode current belongs in milliamperes, sleep current in microamperes, bias and leakage in nanoamperes or picoamperes. A table that mixes all four needs a clear column heading for each row group. When a value like 5e-7 mA appears in a report, rewrite it as 0.5 nA or 500 pA, which is easier to read. The conversion page is meant for the moment you need to cross from one group to another, such as comparing a leakage to a load, and for confirming that you have shifted the decimal point by the right number of places. A short habit helps: write the exponent of the result next to the number in your notes, so a later reader can tell 5e-7 mA from 5e-6 mA, which differ by a factor of ten. Many logging tools print results in this exponent form, and the notation is easy to misread at a glance.
Leakage acceptance is a data-sheet question
Whether a leakage current is acceptable cannot be read off a converted number. The page measures no leakage and predicts nothing about a part over temperature. Use the component data sheet, the circuit requirements and a measurement on your own board to answer those questions.