Nine orders of magnitude between two instruments

A bench supply reports its output in milliamperes, and a picoammeter or electrometer reports in picoamperes. Anyone who measures a leakage path in a test fixture, or who builds a sensitive amplifier stage next to a power supply, has to talk about both. This page converts mA to pA by moving the decimal point nine places. It performs the unit step and nothing else. A result like 10,000,000,000 pA says nothing about whether such a current can be measured accurately, and the practical limits of a measurement lie in the instrument, the cabling and the environment. Readers range from graduate students writing a methods section to technicians documenting a test fixture, and what they share is a table in which one column came from a power supply and another from a very sensitive meter, so every value has to be shown on one scale before the table is checked.

The factor of one billion

Milli means 10⁻³ and pico means 10⁻¹², so one milliampere equals 10⁹ picoamperes. The formula is pA = mA × 1,000,000,000. The default input of 10 mA returns 10,000,000,000 pA, and the reverse conversion divides by one billion. Because the prefixes in the SI Brochure are defined exactly, no approximation enters the factor. The displayed result may carry a small floating-point artifact in the last digit for very large numbers, which has no effect on the value in practice. A mental check is that three prefix steps, milli to micro to nano to pico, each multiply by 1,000.

A ladder of prefixes

It helps to walk the ladder. 1 mA is 1,000 µA, which is 1,000,000 nA, which is 1,000,000,000 pA. A current of 3.3 mA therefore equals 3.3 billion pA, and 0.5 mA equals 500,000,000 pA. Going down the ladder is multiplication and going up is division. If you are unsure of one step, convert through the neighboring unit, check the intermediate value and then continue. The microampere and picoampere pages follow the same pattern, so you can use any of them to verify a number in a report that contains several units of current. The ladder also shows why intermediate units are worth using when a range is wide. A supply of 250 mA reads as 250,000,000,000 pA, which nobody can read at a glance, while the same current as 250,000 µA or 0.25 A is clear. Choose the unit that keeps the number between 1 and 1,000 whenever you can, and use pA only for the quantities that are truly small.

Single-channel currents in a biology lab

Patch-clamp recordings in neuroscience and cell biology measure the current through individual ion channels, and those currents are of the order of a few picoamperes. A channel current of 2 pA equals 0.000000002 mA, which shows how far below the milliampere scale the signal lies. The amplifier needs shielding, low-noise components and careful grounding to see it, since the pickup from nearby equipment can be larger than the signal. The page helps in a methods section where the recorded current in pA is compared with the milliampere rating of the stimulating equipment in the same setup.

Photodiode dark current

A photodiode in a light meter or optical sensor leaks a small dark current even without light, a value that data sheets give in picoamperes or nanoamperes. An illustrative dark current of 50 pA is 0.00000005 mA. The useful signal under light might be many nanoamperes, so the dark current sets the lowest light level that can be measured. When a design adds an amplifier whose input bias current is also in picoamperes, converting every figure to pA lets you compare the contributions. If the bias current is 10 pA and the dark current 50 pA, the dark current is the larger error source. Both values depend on temperature, and dark current of silicon photodiodes commonly rises quickly as the part warms, so a figure quoted at 25 °C does not describe a sensor inside a hot enclosure. Convert the datasheet value for the temperature you need, if the sheet provides one, and not for the one that makes the headline number look best.

Insulation and leakage through high resistance

Ohm's law shows how small these currents get. A 5 V source across a 100 GΩ insulator drives 5 / 10¹¹ A = 50 pA, which is 5 × 10⁻⁸ mA. A moisture film or a dirty circuit board can lower that resistance by orders of magnitude and raise the leakage into the nanoampere range. That is why precision front ends use guard rings and cleaned boards, and why sensitive measurements are often made in a dry enclosure. A film that lowers the resistance to 1 GΩ would let the same 5 V drive 5 nA, which is 5,000 pA, a hundred times the original leakage. If a sensor reading drifts when the humidity changes, a leakage path of this kind is a typical suspect. Converting the numbers to pA helps you see whether the leakage is comparable to the signal.

Reading very large and very small numbers

Results near 10¹⁰ are easy to misread. Group digits in threes when you write them, 10,000,000,000 pA, or use scientific notation, 1 × 10¹⁰ pA, so the exponent is visible. When going from pA to mA, the result has nine leading zeros for a current of a few picoamperes, and a spreadsheet may show it as 2E-09. Both forms are the same number. For a report, quote the value with the number of significant digits supported by the instrument, which for a picoammeter is usually three or four. When two currents are subtracted, such as a signal and a baseline, do the subtraction in one unit before converting, because a result that is the small difference of two large numbers loses precision if each was rounded separately. A reading of 3,300,000,000 pA minus 3,299,999,000 pA is 1,000 pA, and a rounding of either term to three digits would erase the answer.

The letter p and capital P

The symbol for pico is a lowercase p, and pA means picoampere. A capital P is the prefix for peta, 10¹⁵, so PA would be a petaampere, a unit nobody uses for current. The risk is in the case-insensitive world of file names and text searches, where pA and PA are the same string. In tables, keep the original capitalization and add the unit to every number. If a document uses both mA and pA, a quick review that confirms each appears only where its scale fits can catch a slip that a spell checker will not.

Instrument limits at picoampere currents

The page rewrites a current in picoamperes and does not tell you what your electrometer, its range or its noise floor can resolve. Those come from the instrument manual. Measuring a current of a few picoamperes needs guarded cabling, low-leakage connectors and a shielded environment, and none of that is part of a unit conversion. Use the converted figure for arithmetic and consult the instrument documentation for what can be measured reliably.