MEASUREMENT & METHODS

Microamperes (µA): current unit guide

µA expresses current in microamperes.

Measurement basis

The recorded factor is 10^-6 A per µA.

Definition conventions

Prefixes are SI decimal powers, and conversions stay within the current quantity.

Conversion method

Multiply µA by 10^-6 for the current reference. Retain the original measurement precision.

Reference equivalent of µA

1 µA = approximately 0.000001 A.

Recorded scale factors: 0.000001 for µA; 1 for A.

Worked example

Known input: 10 µA. Reference equivalent: 0.00001 A. The return conversion gives approximately 10 µA.

The small ampere result preserves the source current.

Common reference values

Input (µA)Reference equivalent (A)
10.000001
50.000005
100.00001
250.000025
500.00005
1000.0001

Compare one µA with other units

Target unitEquivalent of 1 µADefinition guide
Amperes (A)0.000001Read definition
Milliamperes (mA)0.001Read definition
Nanoamperes (nA)1000Read definition
Kiloamperes (kA)1e-9Read definition
Picoamperes (pA)1000000Read definition
Femtoamperes (fA)1000000000Read definition

One millionth of an ampere

A microampere (µA) is 10⁻⁶ A. The ampere is the SI base unit of electric current, named for André-Marie Ampère. Since the 2019 revision of the SI, the ampere is defined by fixing the elementary charge at exactly 1.602176634×10⁻¹⁹ C, so one ampere is the flow of 1/(1.602176634×10⁻¹⁹) elementary charges per second, about 6.241509×10¹⁸. One microampere is therefore about 6.241509×10¹² charges per second, and 1 µA equals 1 µC/s. Before 2019 the ampere was defined by the force between two parallel wires, 2×10⁻⁷ N per metre. The site lists converters between microamperes and amperes, milliamperes, nanoamperes, kiloamperes, picoamperes and femtoamperes.

Prefix conversions

The factors are powers of ten. One µA is 0.000001 A, 0.001 mA, 1,000 nA, 1,000,000 pA and 10⁹ fA, and it is 10⁻⁹ kA. In the other direction, 1 mA is 1,000 µA and 1 A is 1,000,000 µA. A reading of 0.35 mA is 350 µA. A value of 47 µA is 0.047 mA, and also 47,000 nA. A leakage of 2,500 nA equals 2.5 µA. A conversion only moves the decimal point by three places per step, so errors come from reading the wrong prefix on the meter. Keep the original symbol, because a result off by a factor of 1,000 can pass unnoticed when the number looks plausible.

Battery-powered devices and sleep currents

Low-power electronics are specified in microamperes. A quartz wristwatch draws on the order of 1 to 2 µA. Modern microcontrollers in deep sleep consume from under 1 µA to about 10 µA, depending on the model and the wake sources enabled. Battery life follows from capacity divided by current. A coin cell with an illustrative capacity of 220 mAh, equal to 220,000 µAh, powering a 5 µA load would last 44,000 hours, about 5.0 years, if the cell delivered its full capacity. Real cells lose capacity to self-discharge, temperature and pulses, so the result is an upper estimate. Averaging matters too: a device drawing 20 mA for 1 ms every second uses 20 µA on average.

Sensors, leakage and measurement

Photodiodes produce photocurrents from nanoamperes to microamperes, and a transimpedance amplifier turns them into volts. Across a 100 kΩ feedback resistor, 10 µA gives 1 V. Diode and transistor leakage current at room temperature is typically nanoamperes to microamperes, and it rises quickly with temperature. A multimeter with a microampere range measures through a series shunt, and the voltage drop across the shunt is called the burden voltage. Using a 1 kΩ shunt for a 100 µA reading gives 0.1 V, which may disturb the circuit. Currents below the microampere range need electrometers and careful guarding, because leakage across a printed circuit board of 10 GΩ with 5 V adds 0.5 nA of error.

Human perception and safety context

Microampere currents are well below the levels that people feel through the skin from external sources. The threshold of perception for alternating current at mains frequency is generally cited near 0.5 to 1 mA, which is 500 to 1,000 µA, and it varies by person and contact conditions. Residual current devices for personal protection trip at 30 mA, which is 30,000 µA. Medical equipment applies stricter limits to currents that can reach the heart through a direct path, with leakage limits in the tens of microamperes for cardiac applications in standards such as IEC 60601-1. These values explain why microampere meters appear in medical device testing. A conversion alone cannot judge whether a current is safe, because path, frequency and duration matter.

Notation and the micro sign

The symbol is µA, with the micro sign µ (U+00B5) or the Greek letter mu (U+03BC) followed by a capital A. In ASCII-only text, uA is a common substitute. The prefix micro is distinct from milli, which uses a lowercase m, so mA is a milliampere and is 1,000 times larger. Confusing the two scales a reading by 1,000, so a 20 µA sleep current read as 20 mA would drain a battery in hours rather than years. Do not abbreviate as mcA, which is not an SI symbol, although mcg for microgram is used in medicine. Write the unit with a space after the number, as in 12 µA, and keep the full source symbol when copying a small current reading into another calculation.

Charge, time and microamperes

Current is charge per time, so 1 µA transfers 1 µC every second. A capacitor of 100 µF charging at a constant 10 µA changes voltage at 0.1 V per second, since dV/dt = I/C = 10×10⁻⁶ / 100×10⁻⁶. A current of 50 µA for 2 hours moves 50×10⁻⁶ × 7,200 = 0.36 C, which is 100 µAh. Equivalent amp-hour units connect to capacity ratings: 1 mAh is 3.6 C, and 1,000 µAh is 1 mAh. Electroplating, sensor integration and coulomb counting in battery gauges all use these relations. Keep units consistent when combining microamperes with farads or seconds, converting to base units first.

Ohm's law with microamperes

Voltage, current and resistance combine through V = I R, and microampere currents pair with large resistors. A current of 20 µA through 100 kΩ gives 2 V. A 3 V supply across 1 MΩ passes 3 µA, and across 10 MΩ it passes 0.3 µA, which is 300 nA. Power is also small: 3 µA at 3 V is 9 µW. A pull-up resistor of 100 kΩ on a 3.3 V line carries 33 µA when the line is held low, which can matter in a battery design. Working in microamperes with kiloohm and megaohm values keeps the numbers readable. Convert to amperes and ohms only if a formula or tool expects base units, and then convert back for presentation.

Reading a meter on its microampere range

Handheld multimeters offer a microampere range, often 600 µA or 6,000 µA full scale, in series with the circuit. The meter inserts a small resistance, so the circuit current is slightly lowered. Using the 6,000 µA range with a 1 kΩ shunt, a reading of 120 µA drops 0.12 V. Switching between ranges can transiently open the circuit and reset a microcontroller, so some bench meters use a make-before-break arrangement. For sleep-current work, a source meter or a current probe with nanoampere resolution captures the short wake pulses that a slow multimeter averages away. Note the range and the burden voltage next to any reading you plan to compare.

Precision and checking

  • Keep original current resolution.
  • Retain the micro prefix.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →