Twelve orders of magnitude apart
The femtoampere and the milliampere sit twelve powers of ten apart. A milliampere is the scale of LEDs, sensors, microcontroller pins and the standby draw of small devices. A femtoampere is the scale of leakage through insulators and the signal from single-ion detectors. Comparing the two is a way to appreciate how much dynamic range a measuring system covers. An instrument that spans both would need a range of one trillion to one. This converter makes the comparison direct: enter a current in femtoamperes and the result is in milliamperes. The default of 10 fA converts to 1e-11 mA. The factor of 10 to the minus 12 is exact, because it is the ratio of two SI prefixes, femto at 10 to the minus 15 and milli at 10 to the minus 3, as listed in the NIST table of decimal prefixes.
Where the factor 1e-12 comes from
To convert fA to mA, go through the ampere. One fA is 1e-15 A. One mA is 1e-3 A. Dividing the first by the second gives 1e-15 divided by 1e-3, which is 1e-12. So 1 fA is 1e-12 mA, and 1 mA is a trillion fA. A thousand femtoamperes is one picoampere, which is 1e-9 mA. A million femtoamperes is one nanoampere, which is 1e-6 mA. A billion is one microampere, which is 1e-3 mA. This ladder helps as a mental check. If your result is 1e-11 mA for 10 fA, you can see that the answer 1e-11 mA has ten zeros after the decimal point before the digit one.
A typical LED current in femtoamperes
A standard indicator LED runs at about 20 mA, a figure that appears in thousands of hobby circuits. Expressed in femtoamperes, that is 2e13 fA, or twenty trillion. Enter 2e13 in the converter and the result is 20 mA. A low-power microcontroller in deep sleep might draw 1 µA, which is 1e9 fA and 0.001 mA. The leakage current in an idle transistor of 100 fA corresponds to 1e-10 mA. Placing these three values side by side shows the contrast: the LED draws about 2 times 10 to the 11th times the transistor leakage. These are illustrative values, since actual devices vary widely. The comparison explains why leakage is negligible in a single device but important in a chip with billions of them.
Leakage in large chips
Femtoampere leakage becomes significant when multiplied. A processor with several billion transistors and an average off-state leakage of 100 fA each would draw 100 fA times 5 billion, which is 5e-4 A, or 0.5 mA, from leakage alone in this simple illustration. In practice, leakage per device is often larger and varies with temperature, voltage and process, and it forms a substantial part of the power budget of modern chips. This is why designers use techniques such as power gating and multiple threshold voltages. Converting fA to mA is the sort of arithmetic that tells you whether per-device leakage adds up to something that matters. The example numbers are chosen for round arithmetic and do not describe any real product.
Measuring small currents on a milliampere meter
An ordinary multimeter has a resolution on the order of microamperes on its lowest current range, so it cannot see femtoamperes at all. A reading of 0.000 mA means only that the current is below the instrument's resolution. To detect currents of 10 fA you need an electrometer or a picoammeter with femtoampere resolution. If you want to compare the specification of such an instrument with a meter, converting units is useful. A resolution of 0.1 fA is 1e-13 mA, while a typical multimeter resolution of 0.001 mA is 1e10 times coarser. The gap illustrates why specialized equipment exists. The numbers are illustrative, and instruments differ widely in range and resolution.
Battery self-discharge and long-life devices
Long-life devices such as sensors that run for years on a coin cell care about currents far below a milliampere. A CR2032 cell, with a capacity in the range of 200 mAh, supplies an average of 0.01 mA for about 20,000 hours, or roughly 2.3 years, ignoring self-discharge and other limits. In femtoampere terms, 0.01 mA is 1e10 fA. Leakage paths in the circuit at the level of picoamperes or femtoamperes are negligible next to that. A sleep current of 1 µA, which is 1e9 fA, would in principle run the same cell for 200,000 hours, more than 22 years, which is longer than the cell's shelf life, so self-discharge dominates. The example is simplified and uses round figures. It shows how the units line up when you compare leakage with a battery budget.
Reading the output of a very small result
The default result is about 1e-11, which written out is 0.00000000001. A result with this many zeros is easy to misread, so use exponent notation when writing it down, and double check by counting the exponent steps: femto to pico is 3, pico to nano 3, nano to micro 3, and micro to milli 3, for a total of 12. If your result has fewer than ten zeros, a step is missing. In words, 10 fA is ten trillionths of a milliampere, a phrasing that is hard to misread.
Using the reverse direction
Switch the menus to convert milliamperes into femtoamperes. A 1 mA current is 1e12 fA, which the converter gives as 1,000,000,000,000. Half a milliampere is 5e11 fA. A 0.001 mA, or 1 µA, current is 1e9 fA. This direction is useful when you need to compare a modest current with a leakage specification expressed in fA. For example, a leakage of 500 fA against a 0.5 mA load is a ratio of 5e-10 divided by 0.5, which is one part in a billion. Seeing the ratio in the same unit makes the insignificance of leakage in that circuit apparent. For high-impedance sensing circuits, the opposite conclusion applies, and the same ratio can dominate.
The ladder from femtoamperes up to milliamperes
A worked ladder makes the scale concrete. Start with 1,000 fA, which is 1 pA and 1e-9 mA. A current of 50 pA, which is 50,000 fA, becomes 5e-8 mA. A current of 1 nA, which is 1,000,000 fA, becomes 1e-6 mA. A current of 1 µA, which is 1,000,000,000 fA, becomes 0.001 mA. Each step up is a factor of 1,000, and the milliampere value gains three orders of magnitude. If you enter each of those femtoampere values in the converter, you can watch the exponent of the result climb from minus 9 to minus 3. Using the page this way is a good exercise for students who find the SI prefixes abstract, because the same physical current is rewritten as an ever-larger number of ever-smaller units.
Average current of a duty-cycled device
Battery-powered sensors spend most of their time asleep and wake briefly to measure and transmit. The average current is the time-weighted mean of the two states. Suppose a node draws 10 mA while active for 1 percent of the time and 2 µA, which is 0.002 mA, during the other 99 percent. The average is 0.01 times 10 plus 0.99 times 0.002, which is 0.1 plus 0.00198, or 0.10198 mA. The sleep current contributes only about 2 percent of the total, so it hardly matters in this example, and reducing it further from 2 µA to a few nanoamperes would change little. This is a typical result and it explains why designers first shorten the active period. The figures are illustrative, and a real design must also include the leakage of regulators and sensors.
Dynamic range of instruments
A range of one trillion to one is beyond any single analog-to-digital converter. A 24-bit converter resolves about 16.8 million levels, which spans seven decades, and a 40-bit converter resolves about 1.1 trillion. Instruments that cover fA to mA therefore switch gain ranges, much like a multimeter changes its range, with each range covering a limited span. The change of range introduces transients, and settling time at the lowest ranges can be minutes because the circuit has to charge stray capacitances with a femtoampere current. For instance, charging a 100 pF cable capacitance by 1 V with a 10 fA current takes 100 pF times 1 V divided by 10 fA, which is 10,000 seconds, nearly three hours. This is why low-current measurements use short, low-capacitance cables.
Reading a mixed-unit data sheet
Data sheets for sensor interface chips often list currents in several prefixes within one table. Imagine an input leakage of 80 fA, a supply current of 1.2 mA and a shutdown current of 0.5 µA. Converting all three to milliamperes gives 8e-11 mA, 1.2 mA and 0.0005 mA. Now the comparison is plain. The supply current is 1.5 times 10 to the 10th times the leakage, and the shutdown current is about 6 million times the leakage. If the sensor produces a signal of 5 pA, which is 5e-9 mA, the leakage of 8e-11 mA is under 2 percent of it, an acceptable error, while the shutdown current would overwhelm it if it flowed through the same node. The values are invented for illustration. The method of putting every line of a table in one unit before comparing is the habit worth keeping.
Cautions for small-current work
The page converts current units and does nothing else. It does not state that a particular current is safe, that a circuit meets a specification or that equipment is adequately rated or protected. The page notes that it does not calculate installation limits, equipment ratings, protection, material response or compliance. Measurement of small currents is subject to noise, leakage and calibration limits that the converter does not model. Use the instrument documentation and a qualified person for any design or safety decision, and treat the converted number only as the same current in another unit.