Currents at the edge of measurement
A femtoampere is one quadrillionth of an ampere, and currents of that size appear where electronics meets single particles. Leakage through the insulating layer of a transistor gate, the dark current of a photodiode, the signal from an ion beam collected in a Faraday cup and the current through a nanoscale junction can all sit in the femtoampere to picoampere range. Instruments that measure them, such as electrometers and picoammeters, are built with special care for insulation, shielding and low-noise input stages. Data sheets quote such currents in fA, but a calculation that follows the SI convention needs amperes. This converter does the step. Enter a current in fA and the result is amperes. The default of 10 fA converts to 1e-14 A. The long string of zeros in the decimal form is the reason scientific notation is nearly always used for these values.
The prefix femto
Femto stands for 10 to the minus 15. The prefix was adopted into the SI by the 12th General Conference on Weights and Measures in 1964, together with atto, and its name comes from the Danish word for fifteen. The NIST page on SI decimal prefixes lists the full set. Compare the neighboring steps: a picoampere is 1,000 femtoamperes, a nanoampere is a million, a microampere is a billion and a milliampere is a trillion femtoamperes. In the other direction, an attoampere is a thousandth of a femtoampere. The ampere itself is defined since 2019 by fixing the elementary charge at exactly 1.602176634 times 10 to the minus 19 coulomb. That definition connects any current directly to a count of electrons per second, which makes femtoamperes unusually concrete: they are small flows of countable charges.
Counting electrons
Dividing a current by the elementary charge gives the number of charges passing per second. One femtoampere is 10 to the minus 15 coulomb per second, and each electron carries about 1.602 times 10 to the minus 19 coulomb, so about 6,241 electrons pass each second. Ten femtoamperes, the default input, is about 62,415 electrons per second. At 1 pA the figure is 6.24 million per second, and at 1 nA it is 6.24 billion. These numbers show why femtoampere measurements are hard but not impossible. A modern electrometer can resolve currents in this range because it integrates the charge over time, and statistical fluctuations in the arrival of discrete charges, called shot noise, set a basic limit. The values are idealized, and they apply to singly charged carriers.
Shot noise as a limit
Shot noise comes from the discrete nature of charge. Its root-mean-square size is the square root of twice the elementary charge times the current times the bandwidth. For a current of 10 fA measured over a 1 Hz bandwidth, that is the square root of 2 times 1.602 times 10 to the minus 19 times 10 to the minus 14, which is about 5.7 times 10 to the minus 17 A, or roughly 0.057 fA. The signal is therefore more than 170 times larger than this noise floor in that bandwidth. Widening the bandwidth to 100 Hz raises the noise by a factor of 10. The example is a theoretical lower bound that ignores amplifier and thermal noise, which are usually larger. It shows why measuring tiny currents involves long integration times and why converting the units correctly matters when comparing a noise specification with a signal.
Turning femtoamperes into a voltage
Electrometers often measure tiny currents by passing them through a very large resistor and measuring the voltage. The relation is Ohm's law, V equals I times R. A current of 10 fA through a 1 teraohm resistor, which is 10 to the 12th ohms, produces 10 times 10 to the minus 15 times 10 to the 12th volts, which is 0.01 V, or 10 mV. In amperes, 10 fA is 1e-14 A, and 1e-14 times 1e12 gives the same 0.01 V. This is the kind of calculation for which an ampere value is needed, and the converter provides it. Real resistors of this size have leakage and noise of their own, and the surface cleanliness of the circuit board becomes important. The example is an idealized illustration of the principle.
Where femtoamperes show up
Several fields work routinely at this level. Semiconductor engineers measure the off-state leakage of transistors, where low-power devices aim for currents in the femtoampere to picoampere range per device. Physicists collect beams of ions or electrons in Faraday cups and read currents in fA. Astronomers and spectroscopists use detectors with dark currents in this range, often cooled to lower them. Biologists recording from single ion channels see currents of a few picoamperes, with the smallest events a tenth of a picoampere or less. A gate leakage of 250 fA, for example, is 2.5e-13 A. These are broad examples, and each field has its own methods and typical values. The converter helps move a number from a data sheet into the SI units of a simulation or a formula.
Practical issues in measurement
Measuring femtoamperes demands more than a good meter. Insulators leak, cables generate charge when flexed, and humidity creates surface currents. Experimenters use guarded triaxial cables, low-leakage materials such as PTFE, shielded enclosures and a stable temperature. Even the voltage on nearby objects can induce currents through capacitance. Because of these effects, a reading of a few fA may be a measurement of the setup itself. Data sheets for instruments list a noise floor or resolution in fA, and a reading near that value should be treated cautiously. The unit conversion has no influence on those limits, but expressing the reading and the specification in the same unit prevents misjudging whether a signal is above the noise.
Scientific notation and display
Because of the number of zeros, amperes values from femtoamperes are best written in scientific notation. 10 fA is 1e-14 A, 250 fA is 2.5e-13 A and 1,000 fA is 1e-12 A. Computers store such values in floating-point form and sometimes show a trailing digit, for example 1.0000000000000002e-14 for 10 fA, which is a binary rounding artifact and not a real difference. Rounding the display to the number of significant figures in your input removes it. When copying the result into a spreadsheet, keep the exponent in the cell or format it as scientific. Truncating a value like 1e-14 to a fixed decimal format can display it as 0, which is a frequent source of confusion.
Going the other way
To convert amperes to femtoamperes, swap the menus. A leakage of 3.2e-13 A becomes 320 fA. A 1 pA current is 1,000 fA, and 1 nA is 1,000,000 fA. The factor is a million billion in the direction from amperes, which is 10 to the 15th. Large numbers like this are easy to mistype, so enter them in exponent notation if the field allows. For quick checks, remember that each step through the prefixes micro, nano and pico changes the number by 1,000, and femto is the fourth step below milli. Counting steps on your fingers and then confirming with the tool is a quick way to catch an extra or missing factor of 1,000.
Droop on a hold capacitor
A practical consequence of femtoampere leakage is voltage droop on a capacitor that holds a sample. The rate of change of voltage equals current divided by capacitance. A leakage of 50 fA, which is 5e-14 A, on a 10 pF hold capacitor, which is 1e-11 F, makes the voltage fall at 5e-14 divided by 1e-11, which is 5 mV per second. On a 1 pF capacitor with only 1 fA of leakage, the droop is 1 mV per second. This calculation needs the current in amperes and the capacitance in farads, which is why a conversion from fA comes first. The droop sets how long a sample-and-hold circuit or a charge-integrating sensor can wait before reading. The example uses round, illustrative values, and real leakage also depends on the voltage, the temperature and the cleanliness of the board.
Electrometers over time
Instruments for tiny charge and current have a long history. Gold-leaf electroscopes in the 18th and 19th centuries showed the presence of charge by the spreading of two thin leaves. Quadrant electrometers added a way to measure potentials, and vacuum-tube electrometers in the 20th century could detect currents near a femtoampere. Modern instruments use field-effect transistor inputs or integrating amplifiers with very high input resistance. What has not changed is the need for careful insulation, since the same surface that holds the charge also carries it away. Many laboratories still keep a shielded, low-noise corner for such work. The ampere values in modern data sheets are the direct descendants of those early efforts, now referenced to the elementary charge.
Entering values without slips
Entering a very small number needs care. If the field accepts exponent notation, type 2.5e2 for 250. A number like 0.000000000000025 is easy to mistype by one zero, and the error is a factor of 10. Two units cause frequent confusion at this scale: fA for femtoampere and fF for femtofarad, a unit of capacitance used in chip design. They look alike but measure different quantities. Another trap is the letter case. A capital A is the ampere, and a lowercase a in front of a letter can be the prefix atto, which is 1,000 times smaller than femto. After the conversion, check the exponent. A value in fA should drop by 15 in the exponent when expressed in amperes, so 3.2 times 10 to the 2nd fA becomes 3.2 times 10 to the minus 13 A.
Limits of a fA to A conversion
The tool changes the unit of an electric current. It does not measure or validate a current, estimate leakage in a device, design a measurement circuit or check any equipment against a specification, rating or standard. The page states that it does not calculate installation limits, equipment ratings, protection, material response or compliance. The result is the same current in amperes. Use the instrument documentation and a qualified engineer for design decisions, and carry the context of the measurement, such as bandwidth, temperature and averaging, alongside the number.