Leakage on one side, signals on the other

Femtoamperes and microamperes sit nine orders of magnitude apart and belong to different parts of a datasheet. Microamperes describe supply currents of low-power microcontrollers in sleep mode, bias currents of sensors, and the output of many photodiodes. Femtoamperes describe leakage through gate oxides, dark currents in the best detectors and the input bias of electrometer amplifiers. Someone comparing the two, for instance a designer checking whether a leakage path matters next to a sleep current, needs a single unit. This page converts the femtoampere figure into microamperes so the two can be compared on the same scale. Typical users are circuit designers, instrument builders and students comparing datasheet columns that use different prefixes.

Nine places of difference

Femto means 10^−15 and micro means 10^−6, so the conversion factor from fA to µA is 10^−9. One microampere is therefore 1,000,000,000 fA, and one femtoampere is 0.000000001 µA. The relationship comes from the SI prefixes in the BIPM SI Brochure and is exact. If the display shows trailing digits such as 1.0000000000000002e-8, those are binary rounding, and the sensible reading is 1 × 10^−8. The micro prefix uses the Greek letter µ, which text without special characters writes as u, so uA means microampere. Between the two lie the picoampere (10^3 fA) and the nanoampere (10^6 fA), so 1 µA also equals 1,000 nA and 1,000,000 pA.

What the default 10 fA looks like in µA

The default entry converts to 1 × 10^−8 µA, or 0.00000001 µA. The size of the result tells you something useful: 10 fA is ten billionths of a microampere. A sleep current of 1 µA is 100,000,000 times larger than a 10 fA leakage, so the leakage is invisible next to it. Only in circuits that deal with signals at the femtoampere level, such as an electrometer front end measuring ion currents, does the leakage start to matter, because the signal itself is of similar size. At 1,000 fA, which is 1 pA, the output is 1 × 10^−6 µA, and at 1,000,000 fA, a single nA, it is 0.001 µA.

Leakage budgets in a low-power design

A battery-powered sensor node may sleep at a few microamperes, and the designer adds up many small leaks to confirm that the total fits. A pin leakage of 250 fA converts to 2.5 × 10^−7 µA, so even a hundred such pins add only 2.5 × 10^−5 µA, which is 25 pA. These leakages are dwarfed by the sleep current of the controller itself. Datasheets for low-power parts often give leakage as a maximum across the full temperature range, and that maximum can be thousands of times the typical room-temperature figure. Real leakage grows steeply with temperature, often doubling every 8 to 10 degrees, so a datasheet value at 25 °C may be far larger at 85 °C. The page converts the number given and does not apply a temperature correction. For illustration, a 220 mAh coin cell feeding a 3 µA sleep current would last about 73,000 hours if nothing else drained it, and a 250 fA leakage changes that by less than one part in ten million.

Photodiodes and dark current

A photodiode produces a photocurrent that rises with light, and a small dark current flows with no light at all. Large-area silicon photodiodes at room temperature have dark currents from picoamperes to nanoamperes, while small, cooled or special devices can reach the femtoampere range. A photocurrent of 0.5 µA is 5 × 10^8 fA, so a dark current of 5 fA would be a one-in-a-hundred-million fraction of that signal. For very dim signals, the dark current sets the noise floor. A conversion to a common unit makes it simple to compute the signal-to-dark ratio before you decide whether a cooled detector is needed. Cooling lowers dark current substantially, which is why astronomy and spectroscopy cameras run cold.

Turning microamperes into billions of femtoamperes

Switch the From and To units to convert µA to fA. 1 µA becomes 1,000,000,000 fA, 0.5 µA becomes 500,000,000 fA, and 3.2 µA becomes 3.2 × 10^9 fA. This direction suits a case where a specification gives a limit in µA, such as a maximum leakage of 1 µA for a pin, and you want to see how many femtoampere-level currents it represents. The answer is a large number, and the usual conclusion is that the specification is far looser than the femtoampere leakage you measured. Full-scale bias currents of 1 µA are also common in low-power circuits, so the same unit appears on both sides of a design.

Measuring femtoampere currents

Currents this small are not measured with a standard multimeter. Electrometers and picoammeters use feedback amplifiers with very high input resistance, and the layout around the input node needs guarding to keep surface leakage on the circuit board from swamping the signal. Humidity, flux residue and even finger oils create leakage paths at the nanoampere level or below. Triaxial cabling and low-leakage insulators such as PTFE help. The practical point for a converter is that the digits you type in the page must come from a measurement with that kind of care, or the extra precision is unjustified. A damp board can leak many orders of magnitude more than a dry one.

Choosing digits and reporting

Report the converted number with the same number of significant figures as the original. A 250 fA reading is 2.5 × 10^−7 µA to two significant figures, and writing 0.00000025000 µA adds nothing. When the numbers become this small, scientific notation is easier to read and less likely to lose a zero. Most spreadsheets also accept a form such as 2.5e-7. If the original value has an uncertainty of several percent, mention it, because leakage currents commonly vary from part to part and with temperature.

Leakage acceptability stays your decision

The page converts a number from one unit of current to another. It does not tell you whether a leakage is acceptable, whether a circuit meets its specification or whether a measurement is valid. It does not calculate installation limits, equipment ratings, protection, material response or compliance. Those decisions rest on the datasheet conditions and the test method behind the number you are converting. When the original value is a maximum, keep it labeled as a maximum after conversion.