A meter in mA and a datasheet in µA

Multimeters and bench supplies show current in milliamperes, while the low-power sections of microcontroller and sensor datasheets list sleep and standby currents in microamperes. A designer who measures 0.35 mA on a prototype and then reads a datasheet limit of 150 µA has to put the two on one scale before saying whether the board passes. This page moves the decimal point three places so that the comparison is direct. It restates the same current in a different unit. It does not say whether a circuit meets a power budget, and the datasheet conditions, such as supply voltage and temperature, still decide whether a figure applies to your board. Many datasheets give a typical value and a maximum value for the same current, so convert both and compare your reading with the maximum, not the typical, if the board has to pass a production test.

The factor of 1,000

Milli means 10⁻³ and micro means 10⁻⁶, so one milliampere is 1,000 microamperes and µA = mA × 1,000. The default input of 10 mA returns 10,000 µA. The conversion is exact, since it follows from the SI prefixes and nothing else, and the reverse direction divides by 1,000. A useful check is that the number of digits grows by three when you convert from mA to µA, so 0.35 mA becomes 350 µA and 2 mA becomes 2,000 µA. When the result has the same number of digits as the input, the page was set to the wrong direction or the units were swapped.

Making sense of a sleeping board

Suppose a prototype reads 0.35 mA when idle, a figure used here for illustration. That is 350 µA, more than twice the 150 µA ceiling in the example above, so something on the board is drawing more than the datasheet implies. Typical culprits are a pull-up resistor holding a line low, a status LED, a voltage divider that stays connected to the battery or a peripheral that was never put to sleep. Converting the reading is the first step. The second is to disconnect parts one by one and watch the microampere figure fall until the board matches the datasheet.

Battery life from a sleep current

A sleep current in microamperes becomes a runtime estimate when it is divided into the cell capacity. A 220 mAh coin cell and a draw of 15 µA, which is 0.015 mA, give 220 / 0.015 = 14,667 hours, about 611 days. The same division using 15 and 220 in mismatched prefixes gives an answer off by a factor of 1,000, which turns two years into two days or two thousand years. Converting the current first keeps both quantities in milliamperes or both in microamperes. Real life cuts the figure, because self-discharge, wake-ups for measurement and cold temperatures all take capacity, so treat the result as a ceiling. A board that wakes for 2 seconds every hour at 8 mA adds a time-weighted average of about 4.4 µA, calculated as 8 mA × 2 / 3,600 = 0.0044 mA, which is 4.4 µA. That is nearly a third of the 15 µA sleep figure, so the wake-ups cannot be ignored in the budget.

Leakage and protection levels in the same units

Appliance leakage tests and residual-current protection use milliamperes, and a figure like 30 mA for a household trip level is 30,000 µA. A bench instrument measuring leakage on a small device might read 0.2 mA, which is 200 µA, well below the trip level of the protective device. Writing the two in the same unit shows the margin as a ratio of 150. Be careful with the claim that a small number means a safe device. Safety standards define limits for particular products and tests, and a conversion on this page cannot tell you which limit applies.

Low-current LEDs and optical sensors

An indicator LED designed for low current may be specified at 2 mA, which is 2,000 µA, and some ambient light sensors have outputs of tens of microamperes. Comparing them in µA shows that the LED draws far more than the sensor it sits next to. If a battery-powered device has a status LED lit all the time at 2 mA and a sensor consuming 40 µA, the LED uses fifty times as much current and dominates the budget. Dimming the LED to 200 µA, or pulsing it briefly, is the kind of change that can extend battery life by months, and the numbers are clear only when both sit in one unit.

Reading the reverse direction

Entering a value in µA and choosing mA as the target reports the milliampere figure that a meter on a higher range would show. A reading of 85 µA is 0.085 mA, and 1,500 µA is 1.5 mA. Many meters show only a few digits, so a microampere current on a milliampere range may read as 0.08 or 0.09, a coarse estimate. Using the microampere range, if the meter has one, gives more digits and a more reliable conversion. Keep in mind that adding a meter in series introduces a small voltage drop, called the burden voltage, which can alter the behavior of a low-voltage circuit.

Symbols and keyboard substitutions

The symbol for micro is the Greek letter µ, and text files often replace it with a plain u. A value written 50 uA means 50 microamperes. A value written 50 mA is one thousand times larger, and a scan in which the µ looks like an m can turn a harmless figure into a large one. When you read values from scanned datasheets, verify the order of magnitude against the typical behavior of the part. A sleep current of 50 mA for a microcontroller would be a very poor result, whereas 50 µA is common, and that context helps you decide which was intended. If a value cannot be checked against the part type, ask for the original document or measure it. A copy that has passed through a few conversions of file format is the most likely place for the Greek letter to be lost, and that is precisely where a reader is least likely to notice.

What a microampere figure cannot confirm

The page only restates a current in microamperes. Whether a fuse, a breaker or a coin cell can carry it comes from their own ratings and the datasheet conditions. A figure in microamperes does not tell you whether a circuit is safe, whether a part will survive, or how accurate your meter is at that range. Use the converted number for comparisons and arithmetic, and take limits and conditions from the datasheet and the applicable standards.