31 TOOLS TO EXPLORE

Conductivity in Unit converters

Browse conductivity in unit converters, page 1 of 1. This page includes Electrical conductivity converter; Siemens per meter to Millisiemens per meter converter.

Browse 52 subcategories
Unit converters

Electrical conductivity converter

Express a known electrical-conductivity reading in another supported unit.

Open tool
Unit converters

Siemens per meter to Millisiemens per meter converter

Read siemens per meter in millisiemens per meter.

Open tool
Unit converters

Millisiemens per meter to Siemens per meter converter

Express millisiemens per meter as siemens per meter.

Open tool
Unit converters

Siemens per meter to Microsiemens per meter converter

Convert siemens per meter to microsiemens per meter.

Open tool
Unit converters

Microsiemens per meter to Siemens per meter converter

Read microsiemens per meter as siemens per meter.

Open tool
Unit converters

Siemens per meter to Siemens per centimeter converter

Express siemens per meter in siemens per centimeter.

Open tool
Unit converters

Siemens per centimeter to Siemens per meter converter

Convert siemens per centimeter to siemens per meter.

Open tool
Unit converters

Siemens per meter to Millisiemens per centimeter converter

Read siemens per meter in millisiemens per centimeter.

Open tool
Unit converters

Millisiemens per centimeter to Siemens per meter converter

Express millisiemens per centimeter as siemens per meter.

Open tool
Unit converters

Siemens per meter to Microsiemens per centimeter converter

Convert siemens per meter to microsiemens per centimeter.

Open tool
Unit converters

Microsiemens per centimeter to Siemens per meter converter

Read microsiemens per centimeter as siemens per meter.

Open tool
Unit converters

Microsiemens per centimeter to Millisiemens per meter converter

Express microsiemens per centimeter in millisiemens per meter.

Open tool
Unit converters

Millisiemens per meter to Microsiemens per centimeter converter

Convert millisiemens per meter to microsiemens per centimeter.

Open tool
Unit converters

Microsiemens per centimeter to Microsiemens per meter converter

Read microsiemens per centimeter in microsiemens per meter.

Open tool
Unit converters

Microsiemens per meter to Microsiemens per centimeter converter

Express microsiemens per meter as microsiemens per centimeter.

Open tool
Unit converters

Microsiemens per centimeter to Siemens per centimeter converter

Convert microsiemens per centimeter to siemens per centimeter.

Open tool
Unit converters

Siemens per centimeter to Microsiemens per centimeter converter

Read siemens per centimeter in microsiemens per centimeter.

Open tool
Unit converters

Microsiemens per centimeter to Millisiemens per centimeter converter

Read microsiemens per centimeter in millisiemens per centimeter.

Open tool
Unit converters

Millisiemens per centimeter to Microsiemens per centimeter converter

Express millisiemens per centimeter as microsiemens per centimeter.

Open tool
Unit converters

Millisiemens per meter to Microsiemens per meter converter

Read millisiemens per meter as microsiemens per meter.

Open tool
Unit converters

Millisiemens per meter to Siemens per centimeter converter

Express millisiemens per meter as siemens per centimeter.

Open tool
Unit converters

Millisiemens per meter to Millisiemens per centimeter converter

Find the millisiemens-per-centimeter equivalent of a per-meter value.

Open tool
Unit converters

Microsiemens per meter to Millisiemens per meter converter

Read microsiemens per meter as millisiemens per meter.

Open tool
Unit converters

Microsiemens per meter to Siemens per centimeter converter

Express microsiemens per meter as siemens per centimeter.

Open tool
Unit converters

Microsiemens per meter to Millisiemens per centimeter converter

Find the millisiemens-per-centimeter equivalent of microsiemens per meter.

Open tool
Unit converters

Siemens per centimeter to Millisiemens per meter converter

Read siemens per centimeter as millisiemens per meter.

Open tool
Unit converters

Siemens per centimeter to Microsiemens per meter converter

Express siemens per centimeter as microsiemens per meter.

Open tool
Unit converters

Siemens per centimeter to Millisiemens per centimeter converter

Find the millisiemens-per-centimeter equivalent of siemens per centimeter.

Open tool
Unit converters

Millisiemens per centimeter to Millisiemens per meter converter

Read millisiemens per centimeter as millisiemens per meter.

Open tool
Unit converters

Millisiemens per centimeter to Microsiemens per meter converter

Express millisiemens per centimeter as microsiemens per meter.

Open tool
Unit converters

Millisiemens per centimeter to Siemens per centimeter converter

Find the siemens-per-centimeter equivalent of a millisiemens-per-centimeter value.

Open tool

A material property in six common units

Electrical conductivity describes how well a material carries current, independent of its size. The topic has 31 pages covering six units: siemens per meter, millisiemens per meter, microsiemens per meter, siemens per centimeter, millisiemens per centimeter and microsiemens per centimeter. The Electrical conductivity converter handles every pair. Direct pages include Siemens per meter to Siemens per centimeter converter, Microsiemens per centimeter to Siemens per meter converter, Millisiemens per centimeter to Siemens per meter converter and Microsiemens per centimeter to Millisiemens per centimeter converter. The units combine a siemens prefix with a length basis of meters or centimeters, which gives two scales to keep straight.

The meter and centimeter bases

The SI unit is the siemens per meter. Water quality and laboratory work traditionally use the centimeter basis, because conductivity cells are built around a centimeter cube. Since one meter is 100 centimeters, a value per centimeter is 100 times larger when written per meter, so 1 S/cm equals 100 S/m. A quantity of 1 mS/cm equals 0.1 S/m, 100 mS/m and 1,000 µS/cm. Most conversion errors in this topic come from losing track of the factor of 100 that separates meters from centimeters, alongside the factor of 1,000 between prefixes. Writing both steps out avoids the trap. For example, 0.5 S/m is 5 mS/cm and 5,000 µS/cm, while 0.5 S/cm would be 50 S/m, a hundred times more conductive material.

Typical values for water

Conductivity is the standard quick measure of dissolved ions in water. Ultrapure water at 25 °C has a conductivity of about 0.055 µS/cm, equivalent to a resistivity of 18.2 megohm centimeters. Distilled water commonly reads a few µS/cm because of absorbed carbon dioxide. Tap water typically ranges from tens to several hundred µS/cm, depending on the source. Seawater is around 50 mS/cm, or about 5 S/m. These are approximate figures that vary with location and temperature. In µS/cm, a drinking water reading of 400 is 0.04 S/m, a quick conversion that the Microsiemens per centimeter to Siemens per meter converter performs.

Metals and other conductors

Metals sit at the other end. Copper has a conductivity of about 5.96 × 10^7 S/m at 20 °C, the reference value behind the International Annealed Copper Standard, in which pure annealed copper is defined as 100 percent IACS. Aluminum is roughly 3.5 × 10^7 S/m and stainless steels are tens of times lower than copper. Semiconductors range over many orders of magnitude depending on doping, and insulators fall below 10^-10 S/m. For these materials the S/m unit is standard. A value of 5.96 × 10^7 S/m equals 5.96 × 10^5 S/cm, which shows why S/cm is rarely used for metals. Soil is another case where conductivity matters: agronomists measure the electrical conductivity of a soil extract in dS/m, where 1 dS/m equals 0.1 S/m and 1 mS/cm, to judge salinity stress for crops. Because deciSiemens per meter is numerically the same as millisiemens per centimeter, a reading in either form can be converted with the mS/cm pages in this topic.

Temperature and measurement

Conductivity of an aqueous solution rises with temperature, about 2 percent per degree Celsius for many natural waters, so readings are reported at a reference temperature, usually 25 °C. Meters apply a compensation factor to refer a reading to 25 °C. Always check whether a stated value is raw or compensated. Probes also need calibration with standard solutions, such as 1,413 µS/cm potassium chloride, which is a commonly used standard at 25 °C. Converters change the unit of a number and cannot correct for temperature, so state the reference temperature next to your converted figure. Frequency and electrode fouling affect readings too.

Conductivity, TDS and salinity

Total dissolved solids meters estimate TDS in mg/L from conductivity using a factor, commonly in the range of 0.5 to 0.7 depending on the mix of ions. A reading of 500 µS/cm at a factor of 0.65 gives roughly 325 mg/L. That factor is an approximation, so the TDS figure is only as good as the assumption. Salinity of seawater is computed from conductivity using the practical salinity scale and temperature and pressure corrections, which is outside the converters. The pages here convert the conductivity reading itself, and you would apply any TDS or salinity method separately according to the standard for your application.

Conductivity and resistivity

Resistivity is the reciprocal of conductivity, so a conductivity of 5.96 × 10^7 S/m corresponds to a resistivity of 1.68 × 10^-8 ohm meters. The Electrical conductivity converter does not take reciprocals, so go through resistivity first if the source gives it. In water work, resistivity in megohm centimeters equals 1 divided by the conductivity in µS/cm: 1 µS/cm corresponds to 1 megohm centimeter, and 0.055 µS/cm to 18.2 megohm centimeters. Material datasheets for conductors list resistivity, while analytical instruments list conductivity, so conversion often combines a unit change and a reciprocal.

Converting conductivity between S/m and µS/cm

Convert 1,413 µS/cm: that is 1.413 mS/cm, 0.001413 S/cm, 0.1413 S/m or 141.3 mS/m. Convert 2.5 mS/cm to S/m: multiply by 0.1 to get 0.25 S/m. Convert 0.05 S/m to µS/cm: multiply by 10,000 to get 500 µS/cm. Convert 12 mS/m to µS/cm: multiply by 10 to get 120 µS/cm. The factors between per-meter and per-centimeter versions of the same prefix are 100, and the factor between a per-meter and a per-centimeter value with different prefixes combines both. Quick checks on tap water ranges, where a few hundred µS/cm is typical, help confirm the magnitude.

Frequent errors and scope

Typical mistakes are treating µS/cm as µS/m, which is off by a factor of 100, forgetting that a value in mS/cm is 10 times larger than the same value expressed in S/m, and confusing conductivity with conductance. Another is quoting a conductivity without its reference temperature. The converters change units only. They do not compute TDS or salinity, correct for temperature, or judge whether water is safe to drink. For drinking water, aquaculture, agriculture and industrial processes, follow the standard methods and guidelines that apply to your case. When a meter offers auto-ranging, it may switch between µS/cm and mS/cm during a measurement, so note the displayed unit with each reading in a log. A reading of 1.2 on the mS/cm range is 1,200 µS/cm, and mixing that with a reading of 950 on the µS/cm range in a spreadsheet column without conversion produces a misleading trend.

Frequently asked questions

How many S/m is 1 S/cm?
One siemens per centimeter equals 100 siemens per meter.
What is 1,000 µS/cm in mS/cm?
It is 1 mS/cm, which equals 0.1 S/m.
Why do conductivity readings quote 25 °C?
Conductivity changes with temperature, so values are referred to a common temperature to allow comparison.
Can I get TDS from these converters?
No. TDS estimates use a separate conversion factor that depends on the ions present.

Explore related formulas, units and constants →