31 TOOLS TO EXPLORE

Magnetic Flux in Unit converters

Browse magnetic flux in unit converters, page 1 of 1. This page includes Magnetic flux converter; Webers to Milliwebers converter.

Browse 52 subcategories
Unit converters

Magnetic flux converter

Read a known magnetic-flux value in another supported flux unit.

Open tool
Unit converters

Webers to Milliwebers converter

Express magnetic flux in webers as milliwebers.

Open tool
Unit converters

Milliwebers to Webers converter

Read a milliweber flux value in webers.

Open tool
Unit converters

Webers to Microwebers converter

Convert webers to microwebers for a known magnetic flux.

Open tool
Unit converters

Microwebers to Webers converter

Express a microweber flux reading in webers.

Open tool
Unit converters

Webers to Nanowebers converter

Read webers as nanowebers using the decimal nano prefix.

Open tool
Unit converters

Nanowebers to Webers converter

Convert a nanoweber flux to webers.

Open tool
Unit converters

Webers to Maxwells converter

Express magnetic flux in webers as maxwells.

Open tool
Unit converters

Maxwells to Webers converter

Read a maxwell flux value in webers.

Open tool
Unit converters

Maxwells to Milliwebers converter

Convert maxwells to milliwebers for the same magnetic flux.

Open tool
Unit converters

Milliwebers to Maxwells converter

Express milliwebers as a maxwell flux value.

Open tool
Unit converters

Maxwells to Microwebers converter

Read maxwells in microwebers.

Open tool
Unit converters

Microwebers to Maxwells converter

Convert a microweber flux value to maxwells.

Open tool
Unit converters

Maxwells to Nanowebers converter

Express maxwells as nanowebers for the same flux.

Open tool
Unit converters

Nanowebers to Maxwells converter

Read a nanoweber flux amount in maxwells.

Open tool
Unit converters

Webers to Picowebers converter

Read magnetic flux in webers as picowebers.

Open tool
Unit converters

Milliwebers to Microwebers converter

Find the microweber equivalent of milliwebers.

Open tool
Unit converters

Milliwebers to Nanowebers converter

Express milliwebers as nanowebers.

Open tool
Unit converters

Milliwebers to Picowebers converter

Read milliwebers on a picoweber scale.

Open tool
Unit converters

Microwebers to Milliwebers converter

Find the milliweber equivalent of microwebers.

Open tool
Unit converters

Microwebers to Nanowebers converter

Express microwebers in nanowebers.

Open tool
Unit converters

Microwebers to Picowebers converter

Read a microweber amount in picowebers.

Open tool
Unit converters

Nanowebers to Milliwebers converter

Find the milliweber equivalent of nanowebers.

Open tool
Unit converters

Nanowebers to Microwebers converter

Express nanowebers as microwebers.

Open tool
Unit converters

Nanowebers to Picowebers converter

Read nanowebers in picowebers.

Open tool
Unit converters

Maxwells to Picowebers converter

Read magnetic flux in maxwells as picowebers.

Open tool
Unit converters

Picowebers to Webers converter

Read picowebers in webers.

Open tool
Unit converters

Picowebers to Milliwebers converter

Find the milliweber equivalent of picowebers.

Open tool
Unit converters

Picowebers to Microwebers converter

Express picowebers as microwebers.

Open tool
Unit converters

Picowebers to Nanowebers converter

Read picowebers on a nanoweber scale.

Open tool
Unit converters

Picowebers to Maxwells converter

Find the Maxwell equivalent of picowebers.

Open tool

Flux counts field lines through an area

Magnetic flux is the total magnetic field passing through a surface: the flux density times the area, when the field is uniform and perpendicular. Its SI unit is the weber (Wb), named for the German physicist Wilhelm Weber, and one weber equals one volt second. Faraday law states that the voltage induced in a loop equals the rate of change of flux through it, which is why flux sits at the heart of transformers, generators and inductors. This hub has 31 converters, led by the Magnetic flux converter, linking webers, milliwebers, microwebers, nanowebers, picowebers and maxwells. The maxwell is the CGS unit, named for James Clerk Maxwell.

Weber and maxwell, and the prefix steps between them

One maxwell is 10^-8 Wb, or 10 nWb, so one weber equals 100 million maxwells. The Webers to Maxwells converter multiplies by 10^8 and the Maxwells to Webers converter divides by it. Smaller coil measurements often land in microwebers, where 1 µWb equals 100 Mx. The Maxwells to Microwebers converter gives 0.01 µWb per maxwell. In the SI family each prefix is 1,000 apart: 1 Wb is 1,000 mWb, 1 mWb is 1,000 µWb, and so on down to picowebers. With so many near-identical names in the list, it helps to say the target unit aloud before choosing the converter, because the titles differ by a single prefix.

From flux density to flux

For a uniform field, flux equals B times the area times the cosine of the angle between the field and the surface normal. A field of 0.5 T through a coil face of 20 cm² gives 0.5 × 0.002 = 0.001 Wb, which the Webers to Milliwebers converter reports as 1 mWb. Tilt the coil by 60 degrees and the flux halves to 0.5 mWb. In CGS terms 1 G over 1 cm² is exactly 1 Mx, which is how the maxwell was constructed. This makes older literature easy to read: a core cross-section of 10 cm² at 15,000 G carries 150,000 Mx, and the Maxwells to Webers converter turns that into 0.0015 Wb.

Transformer cores in milliwebers

A transformer winding on a 50 Hz supply obeys V = 4.44 × f × N × Φmax for sinusoidal voltage, where Φmax is the peak core flux. With 230 V, 50 Hz and 500 turns, the peak flux is 230 / (4.44 × 50 × 500), about 2.07 mWb. The Milliwebers to Webers converter gives 0.00207 Wb for use in base-unit formulas. Dividing by the core area gives the flux density, and engineers keep it below the saturation level of the steel, usually around 1.5 to 1.7 T for silicon steel. Doubling the frequency halves the flux needed for the same voltage, which is why aircraft power systems at 400 Hz use smaller cores. The same equation explains why a 60 Hz transformer connected to a 50 Hz supply runs at a higher peak flux and may saturate, drawing heavy magnetizing current, so nameplates state the frequency range alongside the voltage. The 4.44 constant is 2π divided by the square root of two, rounded, and it applies to a sine wave only.

Tiny fluxes in sensors and superconductors

At small scales flux is measured in microwebers or nanowebers. Search coils, flux loops in fusion experiments and the pickup coils of magnetometers report such values. The superconducting flux quantum, h/2e, is about 2.0678 × 10^-15 Wb, or 2.07 femtoweber, and SQUID sensors resolve a small fraction of it. The Nanowebers to Picowebers converter and the Picowebers to Webers converter handle the intermediate steps. Remember that an electrical integrator measures the change in flux between two states, not the absolute flux, so a stated reading is a difference unless the instrument documents a zero reference. Record both the starting and ending conditions. Calibration labs reference small coil fluxes to the Josephson and quantum Hall standards, but practical engineers more often check an integrator with a known calibration coil and a stable current source. Each value in the chain can be converted with the prefix tools here, for example from 3,500 nWb to 3.5 µWb, a reading from a search coil placed in a test fixture.

Flux linkage and the number of turns

A coil with N turns links N times the flux of a single loop. Flux linkage, N times Φ, is also measured in weber-turns, and inductance equals the flux linkage per unit current. A 200-turn coil with 0.8 mWb through each turn has a linkage of 0.16 Wb-turns. If it carries 4 A, its inductance is 0.04 H. The converters on this hub convert a flux value; they do not multiply by turns. Check whether a data sheet quotes flux per turn or total linkage before using a number, since the factor of N can be 100 or more. Handbooks sometimes call linkage simply flux, which hides the multiplication.

Maxwell in old literature

The maxwell appears in older magnetics texts, magnetic recording papers and some laboratory instruments built before SI took over. A magnetic tape head might be described as delivering a few hundred maxwells to the media. The Webers to Maxwells converter helps when a modern SI design needs to check an old specification, and the Maxwells to Milliwebers converter divides by 10^5. A flux of 50,000 Mx is 0.5 mWb. The unit still has a niche, and some US permanent magnet literature quotes magnetic circuit flux in maxwells alongside gauss and oersteds. Convert to webers once, then do the calculation in SI throughout. A practical case is reading a Helmholtz-coil calibration sheet from an old instrument, where a search coil of known area and turns is pulled out of a field and an integrator records the flux change in maxwell-turns. Dividing that reading by the turns and then by the coil area yields a flux density in gauss, a second step that sits on the magnetic flux density topic, while this hub only supplies the flux in a unit that fits modern formulas.

Common confusions

Flux is not flux density. A weber is a quantity of flux, and a tesla is one weber per square meter, so a field can be strong while the flux is small if the area is small. Another confusion is between the weber and the weber per square meter, which is a tesla. A third is the sign: flux through a loop has a direction relative to the loop normal, and the converters preserve sign. The unit symbols Wb and Mx are case-sensitive, and mWb is a milliweber while MWb would be a megaweber, which is almost never needed. When a result looks wrong by exactly 10^8, the maxwell step is the first place to check.

Frequently asked questions

How many maxwells are in a weber?
100,000,000. One maxwell is 10^-8 Wb, so the Webers to Maxwells converter multiplies by 10^8.
What is the difference between flux and flux density?
Flux density is flux per unit area. One tesla equals one weber per square meter, and flux is the density times the area.
Is a weber the same as a volt second?
Yes. By Faraday law, a flux changing at one weber per second induces one volt, so 1 Wb = 1 V·s.
Do these tools include the number of turns?
No. They convert a flux value between units. For a coil, multiply by the turns separately to get the flux linkage.

Explore related formulas, units and constants →