SI flux meets CGS flux
Magnetic flux is reported in webers in SI documents and in maxwells in older CGS-based sources. A loudspeaker magnet catalog, a magnetic particle testing procedure, a fluxmeter manual or a vintage transformer note may still use maxwells, while a modern design calculation uses webers or milliwebers. This page converts a flux in milliwebers to maxwells so the two sets of numbers can be compared. Enter the SI value and read the CGS value, or flip the units for the other direction. The conversion is a fixed factor of 100,000, which is short enough to remember yet long enough that a slip of one zero is common, so an automatic check is worth having.
Where 100,000 comes from
The maxwell is the CGS unit of flux, equal to one gauss times one square centimeter. The weber is one tesla times one square meter. A tesla is 10,000 gauss, and a square meter is 10,000 square centimeters, so one weber equals 10^8 maxwells. A milliweber is a thousandth of that, which is 10^5 or 100,000 maxwells. The formula is Mx = mWb × 100,000. NIST SP 811 gives the CGS-to-SI relation for the maxwell as 10^-8 Wb. The factor is exact, since it follows from the definitions, and there is no measurement uncertainty in the conversion itself.
From SI flux to the CGS maxwell
The page starts with 10 mWb and returns 1,000,000 Mx, or one megamaxwell. Other values follow the same rule. A flux of 0.25 mWb is 25,000 Mx, 3.2 mWb is 320,000 Mx, and 12 mWb is 1,200,000 Mx. Going the other way, 50,000 Mx is 0.5 mWb. These numbers are in the range found in small magnet assemblies and in the cores of small transformers and relays. The figure is total flux through a defined cross section, so it depends on the area as well as on the field strength, a point that matters when you compare two parts of different size.
From flux density and area to flux
Flux equals flux density times area. A magnet face that gives 0.5 T over 20 cm², which is 0.002 m², carries 0.5 × 0.002 = 0.001 Wb, which is 1 mWb. In CGS units the same case is 5,000 G over 20 cm², or 100,000 Mx, matching the 100,000 Mx per mWb. This cross-check is useful when a datasheet gives gauss and square centimeters while your model uses tesla and square meters. The page converts a flux value. It does not multiply field and area for you, so do that step first, and then use the page for the unit change on the result.
Speaker magnets and fluxmeters
Loudspeaker and microphone parts have long been described with CGS data from the era when they were developed, and some catalogs still do. A fluxmeter or a search coil that integrates a voltage over time may show flux in maxwells or in milliwebers depending on the model and its setting. If an instrument displays 400,000 Mx and your notes use milliwebers, the page gives 4 mWb. Converting a reading is quick, but be sure of which mode the instrument is in. Many fluxmeters also need to be zeroed before each measurement because the integrator drifts, and a drifting zero can look like a small flux. A reading in the wrong unit setting can be off by a factor of 100,000, a mistake easy to see once you know the ratio.
Induced voltage and flux change
Faraday's law links flux change to voltage: the average voltage in a coil equals the number of turns times the change in flux divided by the time. A change of 2 mWb in 10 ms in a one-turn coil gives 0.2 V, and in a 100-turn coil 20 V. The weber is the volt-second, which makes this calculation direct in SI units. In CGS, one volt-second is 10^8 Mx, so the same example involves 200,000 Mx. Engineers who keep legacy notebooks in CGS can therefore reuse an old formula by converting the flux first and the time to seconds, and the result comes out in volts. Converting between the two lets you use an old formula with new data. The page does not compute the voltage, only the unit change of the flux.
Reverse conversions
To convert maxwells back, set maxwells as the source and milliwebers as the target. The page divides by 100,000. A flux of 1,200,000 Mx is 12 mWb, and 75,000 Mx is 0.75 mWb. If a document lists megamaxwells, which are 10^6 Mx, one megamaxwell is 10 mWb, so the default result of the page is exactly one megamaxwell. Be careful with the line, a name used for the maxwell in older literature, since one line is one maxwell. Writing the symbol Mx beside every number prevents confusion with the milliweber symbol mWb, because the two have the same first letter in some fonts and in handwriting.
Gauss, tesla and the unit family
Flux and flux density are different quantities, and the unit names are easy to mix up. A weber and a maxwell measure flux, while a tesla and a gauss measure flux density, which is flux per area. One tesla is 10,000 gauss, so a magnet that reads 1,500 G is 0.15 T. This page does not convert flux density, and entering a gauss value as maxwells would give a wrong answer. If you have a field strength and an area, compute the flux first. If you have only a flux, you cannot find the density without the area. Keep a note of the quantity next to each number.
What the page does not provide
The conversion restates a flux in another unit. It does not compute core saturation, magnet strength, leakage, losses or the suitability of a part for a circuit. Magnetic properties depend on the material, temperature and the surrounding path, and datasheets give the conditions. For design, use the manufacturer curves and the relevant standard, and use the converter to keep units consistent while you read documents from different eras. The page uses the fixed definitions of the units, so results are the same each time. When you copy a converted flux into a report, add the original value and unit in parentheses, for example 0.8 mWb (80,000 Mx), so a reader with either convention can verify it.