Measurement basis
Flux and flux density are separate quantities and differ by an area relationship. A flux unit change does not supply the surface information needed for that relationship.
Definition conventions
Maxwell uses the CGS EMU convention.
Conversion method
Use the compatible flux-factor ratio while retaining the source flux definition.
Choose the conversion direction
Select the source flux unit, such as Wb or Mx, before choosing the target.
The weber as volt-seconds
Magnetic flux measures how much magnetic field passes through a surface. The SI unit is the weber, symbol Wb, named for the German physicist Wilhelm Weber. One weber equals one volt-second, so 1 Wb = 1 V·s, and it also equals one tesla times one square meter, 1 Wb = 1 T·m². Faraday law of induction ties the two views together: the voltage induced in a loop equals the rate at which flux through it changes, with a sign set by Lenz law. If the flux through a one-turn loop drops by 1 Wb in 1 second, the loop develops an average voltage of 1 V. The guide here covers the unit and its prefixes, and it does not calculate induced voltage for any circuit.
Flux through a surface, from flux density
For a uniform field perpendicular to a flat surface, flux is the flux density multiplied by the area. A core with a cross section of 10 cm² carrying 0.5 T holds 0.5 × 0.001 = 0.5 mWb of flux. Earth field of 50 µT through a 1 cm² area gives 5 nWb. If the surface is tilted, only the component of the field perpendicular to it counts, which adds a cosine factor to the product. These two examples show why the weber is rarely used with no prefix: ordinary devices handle milliwebers and microwebers, while the weber itself appears in large magnets, transformer cores and the field of a big machine.
The maxwell and the Gaussian system
The maxwell, symbol Mx, is the unit of flux in the centimeter-gram-second system. One maxwell equals one gauss times one square centimeter, which gives 1 Mx = 10^-8 Wb, or 10 nWb. Going the other way, 1 Wb = 10^8 Mx. A flux of 2.5 mWb is therefore 2.5 × 10^5 Mx, and a quantity written as 1.2 × 10^6 Mx is 12 mWb. The maxwell shows up in older magnetics literature and in some manufacturer data for permanent magnets, where total flux from a magnet is quoted in maxwells or kilomaxwells. A conversion error here is typically a slip in the exponent, since the factor is a clean power of ten.
The flux quantum
A superconducting loop can enclose flux only in multiples of a fixed amount, the magnetic flux quantum Φ0 = h / (2e), where h is the Planck constant and e the elementary charge. With the exact values in the SI since 2019, Φ0 is about 2.067834 × 10^-15 Wb, or roughly 2.07 femtowebers. SQUID magnetometers use this to detect extremely small changes in flux, and the Josephson effect links the quantum to voltage standards. The scale makes ordinary prefixes look huge: 1 pWb equals about 484 flux quanta, and 1 µWb equals about 4.8 × 10^8 of them. No everyday device approaches this level, yet it explains why the weber links so directly to fundamental constants.
Flux linkage and turns
A coil with N turns links the flux of every turn, and the total flux linkage is N times the flux through one turn. It is measured in weber-turns, though a turn is a pure number, so the unit is still the weber. A coil of 200 turns around a core with 0.5 mWb carries a flux linkage of 0.1 Wb-turn. Dividing that linkage by the current gives the inductance in henries: 0.1 Wb-turn at 2 A means 50 mH. Datasheets and papers vary in whether they quote flux or flux linkage, and reading which one is meant avoids a factor-of-N discrepancy when comparing numbers from different sources.
Where flux values appear
Transformer and motor design starts from the flux the core can carry before it saturates, which for silicon steel is on the order of 1.5 to 2 T of flux density. Multiplying by the cross-sectional area gives flux in milliwebers. Magnetic resonance imaging systems and particle accelerator magnets are described mainly through flux density, but the flux appears in sizing of coils. Magnetic flux sensors, such as search coils with an integrator, read flux in volt-seconds directly, which explains why oscilloscope-based flux measurements show V·s on the axis. In every case the weber links the electrical and magnetic quantities through one unit. As an illustration, a transformer winding on 230 V rms at 50 Hz has a peak flux of about V / (4.44 f N), and with 500 turns that is 230 / (4.44 × 50 × 500) = 2.07 mWb. At 60 Hz the same winding would carry about 1.73 mWb, which is why a 50 Hz design needs more core.
Prefix scale from picowebers to webers
The conversions inside the SI are powers of 1000. One weber equals 1000 mWb, 10^6 µWb, 10^9 nWb and 10^12 pWb. A reading of 350 µWb is therefore 0.35 mWb or 350,000 nWb. The prefix µ is the Greek letter mu, and it differs from the lowercase m. Mixing them changes the value by a factor of 1000. Many instruments print µ as u to save space, so u in a column of readings usually stands for micro. For comparison with the Gaussian system, each of these prefixed units also has a maxwell equivalent, so 1 µWb is 100 Mx.
Confusions with flux density and inductance
Flux is not flux density. Flux density, in teslas, is a field per unit area, and flux is the total through a given area. Quoting 0.8 T does not give a flux until an area is stated, and quoting 0.8 mWb does not give a density until the area is known. Flux is also not inductance. A flux of 5 mWb in a coil carrying 2.5 A and 100 turns relates to inductance only through the linkage calculation, which the unit conversion does not perform. Magnetic flux converters change the unit of the same quantity, and they do not move a reading between these different quantities.
Reading a magnet datasheet
Magnet datasheets give flux density at the surface, coercivity and often a total flux. Moving between datasheets that use weber and maxwell is a unit change only. A ring magnet listed with 90,000 Mx of total flux, for instance, carries 0.9 mWb. The total flux that a magnet delivers through a pole piece also depends on the air gap and on the circuit, so the figure on the label is measured under stated conditions. A unit converter helps compare labels, yet the measuring conditions printed beside the value matter as much as the unit. Quoting a flux from a magnet in free air, from the same magnet clamped to a steel yoke, and from a loaded magnetic circuit gives three different numbers for one part, and none of them is an error of unit.
Precision and checking
- Keep original flux measurement precision.
- Retain the surface context separately from the converted unit.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Webers (Wb)
Definition, reference values and linked conversions.
Milliwebers (mWb)
Definition, reference values and linked conversions.
Microwebers (µWb)
Definition, reference values and linked conversions.
Nanowebers (nWb)
Definition, reference values and linked conversions.
Maxwells (Mx)
Definition, reference values and linked conversions.
Picowebers (pWb)
Definition, reference values and linked conversions.
Use a working converter
- Magnetic flux converter
- Webers to Milliwebers converter
- Milliwebers to Webers converter
- Webers to Microwebers converter
- Microwebers to Webers converter
- Webers to Nanowebers converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.