Measurement basis
Its recorded factor is 10^-6 Wb.
Definition conventions
Maxwell uses the CGS EMU convention.
Conversion method
Multiply µWb by 10^-6 for the flux reference.
Reference equivalent of µWb
1 µWb = approximately 0.000001 Wb.
Recorded scale factors: 0.000001 for µWb; 1 for Wb.
Worked example
Known input: 10 µWb. Reference equivalent: 0.00001 Wb. The return conversion gives approximately 10 µWb.
The small reference value retains the source flux.
Common reference values
| Input (µWb) | Reference equivalent (Wb) |
|---|---|
| 1 | 0.000001 |
| 5 | 0.000005 |
| 10 | 0.00001 |
| 25 | 0.000025 |
| 50 | 0.00005 |
| 100 | 0.0001 |
Compare one µWb with other units
| Target unit | Equivalent of 1 µWb | Definition guide |
|---|---|---|
| Webers (Wb) | 0.000001 | Read definition |
| Milliwebers (mWb) | 0.001 | Read definition |
| Nanowebers (nWb) | 1000 | Read definition |
| Maxwells (Mx) | 100 | Read definition |
| Picowebers (pWb) | 1000000 | Read definition |
A millionth of a weber
The microweber, symbol µWb, equals 10⁻⁶ Wb. The weber is the SI derived unit of magnetic flux, named for the German physicist Wilhelm Weber, who worked on magnetism with Carl Friedrich Gauss. In SI base units, 1 Wb = 1 kg·m²·s⁻²·A⁻¹, which also equals 1 V·s and 1 T·m². The definition through Faraday induction is the easiest to picture. If a flux of 1 Wb linking one turn of wire falls to zero at a uniform rate in one second, it induces an electromotive force of 1 V. The site converter Webers to Microwebers multiplies by 1,000,000, so 0.00005 Wb becomes 50 µWb. Microwebers suit small coils, sensors and lab fields because everyday flux values in webers carry many leading zeros.
Flux is field times area
Magnetic flux Φ is the integral of the magnetic flux density B over an area, and for a uniform field crossing a flat surface at a right angle it is simply B × A. That relation links microwebers to teslas. Earth surface field of about 50 µT through a square centimeter (10⁻⁴ m²) gives 5 × 10⁻⁹ Wb, or 0.005 µWb. A small ferrite magnet with 5 mT at its face over the same area gives 5 × 10⁻⁷ Wb, which is 0.5 µWb. Tilting the surface reduces the result by the cosine of the angle between the field and the surface normal, and a surface parallel to the field gets no flux at all. This is why a search coil gives its largest signal when its axis points along the field. A 10 cm by 10 cm loop (0.01 m²) in the same 50 µT field, held square to it, links 50 × 10⁻⁶ T × 0.01 m² = 5 × 10⁻⁷ Wb, which is 0.5 µWb, and turning it edge-on drops that to zero.
Faraday induction in microwebers
Faraday law ties flux to voltage: the average electromotive force around a loop equals the change in flux divided by the time it takes, with a minus sign for direction, and for N turns the flux linkage Nφ is what counts. A change of 100 µWb through a single turn in 10 ms induces 100 × 10⁻⁶ ÷ 0.01 = 0.01 V, or 10 mV. A 50-turn coil seeing the same change gives 0.5 V. Running the calculation backward is how flux meters work. They integrate the voltage from a coil over time, because Φ = ∫V dt, and report the result in webers or microwebers. A ballistic galvanometer did this historically, and a modern integrator circuit does it electronically, drifting slowly as the offset voltage accumulates.
Maxwells and the centimeter-gram-second heritage
Older magnetics literature uses the maxwell, the CGS unit of flux named for James Clerk Maxwell. One maxwell equals 10⁻⁸ Wb, so 1 Mx = 0.01 µWb. The site lists a Maxwells to Microwebers converter that multiplies by 0.01 and a Microwebers to Maxwells converter that multiplies by 100. A flux of 5,000 Mx is 50 µWb, and 12 µWb is 1,200 Mx. The CGS unit of flux density, the gauss, equals one maxwell per square centimeter, and 1 G = 10⁻⁴ T. That pairing explains why catalogs for loudspeaker magnets, magnetic stripe heads and some permanent-magnet materials still quote kilomaxwells or gauss when the rest of the datasheet is in SI. The conversion factors are exact because the CGS units are defined from the same base quantities.
Where microweber values appear
Microweber-scale flux appears in search-coil magnetometers, fluxgate sensor cores, the pickup loops of pulse magnetometers for permanent magnets, and the flux linkage of small inductors, relays and sensor coils. Magnet manufacturers measure total flux with a Helmholtz coil and fluxmeter, and a small neodymium disc can come out in the tens to hundreds of microwebers. Hall-effect and magnetoresistive sensor datasheets give sensitivity in volts per tesla rather than in flux, because those sensors respond to flux density at a point. At the opposite extreme, superconducting quantum interference devices count magnetic flux in units of the flux quantum Φ₀ = h/2e, which is about 2.068 × 10⁻¹⁵ Wb, or 2.068 × 10⁻⁹ µWb. Microwebers are therefore enormous compared with the flux that a SQUID resolves.
A worked pass through a Helmholtz coil reading
Suppose a fluxmeter connected to a 200-turn pickup coil reads 40 µWb-turns when a small magnet is pulled out of the coil. Flux per turn is 40 ÷ 200 = 0.2 µWb. Converting to the older unit, 0.2 µWb × 100 = 20 Mx. If the coil area is 2 cm², or 2 × 10⁻⁴ m², the average flux density through it was 0.2 × 10⁻⁶ Wb ÷ 2 × 10⁻⁴ m² = 1 × 10⁻³ T, which is 1 mT or 10 G. The same pull in 50 ms would have induced an average 40 × 10⁻⁶ ÷ 0.05 = 0.8 mV across the winding. These numbers are illustrative, but the chain of steps shows how microweber readings, turns, area and time combine to give field and voltage.
Weber, tesla and ampere-turn do not interchange
Several magnetic units are easy to mix up. The tesla is flux per unit area, so a field in µT cannot be changed to µWb without an area. The weber-turn measures flux linkage for a coil, not for a single loop. Magnetomotive force is in ampere-turns, and magnetic field strength H is in amperes per meter, which describes the source of the field and not the flux through a surface. Inductance links flux to current, since L = Nφ ÷ I, so 200 µWb-turns produced by 0.1 A corresponds to 2 mH. When copying a figure from a data sheet, check whether it is flux, linkage per turn, linkage for the full winding or flux density before applying any scaling. Only a prefix scaling such as Wb to µWb can be done without extra information.
Writing µWb and keeping resolution honest
The symbol is µWb: a lowercase mu, a capital W for Weber and a lowercase b. The SI rule that symbols of units named after people start with a capital letter applies to the W, and the b is lowercase. Typed substitutes such as uWb are common in file names and code. Do not mistake mWb for µWb, which are separated by a factor of 1,000, or MWb for a megaweber, which is 10⁶ Wb and has no routine instrument use. A long decimal in webers does not add accuracy, so a reading of 37 µWb taken to two significant figures should be written back as 3.7 × 10⁻⁵ Wb and not as 0.00003700 Wb, which would suggest four figures that the instrument never produced.
Precision and checking
- Keep measured flux resolution.
- Retain the micro prefix.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Magnetic flux converter
- Microwebers to Webers converter
- Microwebers to Maxwells converter
- Microwebers to Milliwebers converter
- Microwebers to Nanowebers converter
- Microwebers to Picowebers converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.