Flux figures that arrive in different prefixes
Magnetic flux measured with a fluxmeter or computed from a field and an area often comes out in microwebers, while the data sheet of a transformer core, a motor magnet or a loudspeaker driver states flux in milliwebers. A designer or student comparing the two must bring them to one prefix first. This page divides microwebers by 1,000 to give milliwebers, and multiplies by 1,000 for the reverse direction. The relationship is fixed by the SI prefixes. The converter changes the unit only. It does not tell you whether a core will saturate, whether a magnet is strong enough, or whether any device meets a requirement.
Definition and factor
The weber is the SI unit of magnetic flux, equal to one volt-second. The SI Brochure from the BIPM defines milli as 10^-3 and micro as 10^-6, so one milliweber contains 1,000 microwebers. The formula on this page is mWb = µWb × 0.001. With the default input of 10 µWb the result is 0.01 mWb, which the page may display as 0.009999999999999998 because of binary floating-point rounding. Both forms mean the same number. Because the factor is a power of ten, digits carry over unchanged, and only the decimal point moves. 2,500 µWb is 2.5 mWb, and 0.3 mWb is 300 µWb.
Flux in a transformer core
The flux in a core equals the flux density times the cross-sectional area of the core, when the field is uniform. Take an illustrative flux density of 0.3 T in a core with a cross-section of 4 cm², which is 4 × 10^-4 m². The flux is 1.2 × 10^-4 Wb, which is 120 µWb or 0.12 mWb. A datasheet that lists the maximum flux in a core in milliwebers can then be compared with the value you computed in microwebers. This example uses round numbers to show the method and does not describe a particular core. Core saturation limits come from the material data of the manufacturer.
Flux linkage of an inductor
An inductor with inductance L carrying current I has a flux linkage of L times I, in weber-turns. For a 100 µH coil carrying 5 A, the linkage is 500 µWb-turns, which is 0.5 mWb-turns. Dividing by the number of turns gives the flux through each turn, so a 50-turn winding has 10 µWb, or 0.01 mWb, per turn, which is the default value on this page. Power-supply designers use this calculation to check that a core stays below its saturation flux at the peak current. The converter supports the unit step. The inductance, current and core data have to come from your design and the component data sheets.
Induced voltage from a changing flux
Faraday induction says that the voltage in a coil equals the rate of change of flux linkage. If the flux through a single-turn loop changes by 2 mWb in 10 ms, the average voltage is 2 × 10^-3 Wb divided by 10 × 10^-3 s, which is 0.2 V. In microwebers, that same change is 2,000 µWb, and the result stays 0.2 V because one weber per second is one volt. When a scope trace gives a voltage over time, integrating it gives volt-seconds, which equal webers. Having the flux in the prefix that suits the data, microwebers for small changes and milliwebers for large ones, keeps the arithmetic readable without changing the physics.
Magnet datasheets and motor design
Permanent magnet suppliers publish flux density at a surface or total flux at a stated geometry, and motor designers work with flux per pole. Values in the range of a fraction of a milliweber up to several milliwebers are common for small motors and sensors. If a measurement gives 850 µWb for a magnet assembly, that is 0.85 mWb. When you compare two magnets or two measurements, the test geometry, the pick-up coil and the temperature need to match, or the unit conversion will line up numbers that do not describe the same condition. Record the test setup next to the value and convert only after you have confirmed that the setups agree.
Reading and rounding the result
A conversion from microwebers to milliwebers gives a smaller number. Values such as 0.005 mWb are awkward, and many authors keep such values in microwebers, writing 5 µWb. A reasonable rule is to choose the prefix that leaves between 1 and 999 before the unit symbol. If the fluxmeter shows 3 significant digits, keep three in the converted value, so 1,230 µWb becomes 1.23 mWb. Avoid adding digits that the instrument cannot support. Use µWb with the micro sign and mWb with a lowercase m, because a capital M would mean megaweber, a factor of one billion larger. A short worked case shows the habit. A motor magnet measures 640 µWb with one setup and 0.62 mWb with another. Converting the first gives 0.64 mWb, so the two differ by about 3 percent, which is within what a change of pick-up coil or temperature can cause. Seeing the numbers in one unit settles at once whether a gap is a unit slip or a real difference. When the gap is a factor of 1,000 or 1,000,000, suspect a prefix error before suspecting the magnet.
Relating to maxwells and gauss
Older documents may give flux in maxwells. One maxwell is 10^-8 weber, so 1 mWb is 100,000 Mx and 1 µWb is 100 Mx. A magnet specified at 40,000 Mx has a flux of 400 µWb, which is 0.4 mWb. In CGS units, flux density in gauss times area in square centimeters gives maxwells. Converting everything to SI first, then to the prefix of your choice, avoids mistakes that come from converting between two systems and two prefixes in one mental step. The companion page for microwebers and maxwells handles the CGS side of the relationship, while this page handles the SI prefix.
What this page does not cover
The page converts a flux value between two SI prefixes. It does not compute flux from a field, determine saturation, or judge any device for safety, exposure or compliance purposes. The definition of the weber and the prefix values come from the SI Brochure published by the BIPM and from NIST SP 811, listed as sources for this page. Displayed values are rounded, and the engine may show a floating-point tail on some results. Keep the source number and its unit in your notes, and use the manufacturer data and the applicable standards for decisions that depend on the flux.