What magnetic flux is and why the prefix matters

Magnetic flux measures how much magnetic field passes through a surface. For a uniform field that crosses a flat surface at a right angle, the flux is the flux density multiplied by the area. Its SI unit is the weber, symbol Wb, named after the German physicist Wilhelm Weber. One weber is one volt-second, which ties flux directly to induced voltage. Everyday coils, transformers and sensors deal with fluxes far smaller than a whole weber, so the milli and micro prefixes appear constantly. The danger is that milli and micro look alike on a page, and they differ by a factor of 1,000. A data sheet that gives a flux in mWb and a simulation that reports it in µWb cannot be compared until one of them is converted. This page makes that single step: milliwebers in, microwebers out, with the physical quantity unchanged.

The conversion and the default example

The prefix milli stands for one thousandth and micro for one millionth. So 1 mWb is 0.001 Wb and 1 µWb is 0.000001 Wb, and the ratio is 1,000. The page formula is µWb = mWb × 1,000. With the default input of 10 mWb the result is 10,000 µWb. The reverse direction divides by 1,000, so 10,000 µWb returns 10 mWb. The factor is exact. Both prefixes are defined as powers of ten in the International System of Units, and the NIST guide to SI units, Special Publication 811, lists them. No measured constants are involved, which is different from conversions that cross into other unit systems. The only place a decimal can go wrong is in your own copying of the digits, so check that the number of zeros in the answer matches what you expect.

Flux from field and area

A practical way to get a feeling for the size of a weber is to start from flux density. One tesla is one weber per square meter, so a uniform field of 1 T through an area of 1 m² carries 1 Wb. Real surfaces are smaller. An MRI scanner with a 1.5 T field passing through a 1 cm² area, which is 0.0001 m², carries 0.00015 Wb, or 0.15 mWb. Convert that to microwebers and you get 150 µWb. A weak field through a small loop gives much less. Earth's field is tens of microteslas, and through a 10 cm by 10 cm loop, which has an area of 0.01 m², it gives a flux of roughly half a microweber at most, depending on orientation. These are illustrative numbers that show the range. For any given case, you need the actual field and the area projected perpendicular to the field.

A second example: a 0.75 mWb reading

Imagine a simulation of a small inductor that reports the peak core flux as 0.75 mWb, while the core manufacturer lists the saturation flux of the chosen core in microwebers. To compare, convert the simulation result. Multiplying 0.75 by 1,000 gives 750 µWb. Another reading, 2.4 mWb, becomes 2,400 µWb. A value of 0.0035 mWb becomes 3.5 µWb, which shows how a number with leading zeros in one unit turns into a simple number in another. Reading values in the unit that gives a number between about 1 and 999 is the convention in most data sheets, since the digits are easier to scan and less prone to slips. The values here are made up for the example. If your own figure is a peak value, a root-mean-square value or a value at a given current, the conversion treats it the same way, because it only changes the scale.

Flux, voltage and Faraday's law

The weber is the volt-second, and that definition is also how flux is measured in practice. Faraday's law of induction says the voltage induced in a single turn of wire equals the rate at which the flux through it changes. A change of 10 mWb in one millisecond would induce an average of 10 V in a single turn, because 0.01 Wb divided by 0.001 s is 10 V. The same change expressed as 10,000 µWb gives the same answer when 10,000 × 10^-6 Wb is divided by the time. For a coil of N turns the induced voltage is multiplied by N. Search coils and integrating electronics use this relationship to measure fluxes in the microweber range. When you read a datasheet value in volt-seconds, for example for the flux handling of a transformer, it converts directly: one volt-second is one weber.

The maxwell and the CGS system

Older literature, especially in the United States and in some magnetics catalogs, uses the maxwell, symbol Mx, which belongs to the centimeter-gram-second electromagnetic system. One maxwell equals 10^-8 weber. That makes 1 mWb equal to 100,000 Mx and 1 µWb equal to 100 Mx. The converter lists maxwells as an option, so you can check an old figure directly. The related density unit is the gauss, with 1 G equal to 10^-4 T, and a field of 1 G through 1 cm² is 1 Mx. If you read a vintage specification that gives a flux in kilomaxwells, convert it first to webers and then to microwebers. The prefix on the weber side is exact, and the maxwell relation is exact as a definition too, so the converter output is not subject to rounding beyond the number of digits shown.

The magnetic flux quantum

At the smallest scales flux comes in discrete packets. In a superconducting loop the flux is quantized in units of the magnetic flux quantum, h divided by 2e, which since the 2019 revision of the SI has an exact value derived from the fixed Planck constant and the elementary charge. It is about 2.0678 × 10^-15 Wb, or roughly 2.07 femtowebers. SQUID magnetometers use this effect to detect minute changes in flux. A flux of 1 µWb contains about 484 million flux quanta, because 10^-6 divided by 2.0678 × 10^-15 is about 4.84 × 10^8. This is the range where the microweber and its smaller neighbors, nanoweber and picoweber, become natural units. The converter includes nanowebers and picowebers for that reason, and it lets you step down from mWb through µWb toward the quantum scale.

Where this converter helps in practice

Magnetic flux appears in the design of inductors, transformers, solenoids, electric machines, magnetic sensors and the heads of magnetic storage devices. Simulation software tends to report in webers or in the base unit of the model, while data sheets might use milliwebers or microwebers, and measurement instruments may display microwebers directly. A technician comparing a core's rated flux with a simulated peak needs both on the same scale. A student working through a problem on induced voltage might be given flux in milliwebers and asked to enter the result in a table that uses microwebers. In each case the work is the same: multiply by 1,000 or divide by 1,000. Keeping a note of which unit each quantity is in, next to the number, prevents the most common slip, which is mixing the two without noticing.

Common mistakes

The first is a factor error between milli and micro. Remember that going to the smaller unit makes the number bigger, so 10 mWb should become 10,000 µWb and not 0.01 µWb. The second is confusing the unit symbols. The weber is Wb with a capital W, because it is named after a person, and the prefix letter is lowercase m for milli. The symbol MWb with a capital M would be megawebers, a billion times larger than mWb. The third is to confuse flux with flux density: milliwebers are a flux, while milliteslas are a density, and one cannot be turned into the other without an area. A fourth error is to forget that flux through a surface depends on the angle between the field and the surface normal. The converter gives the same numeric quantity in a different unit, nothing more.

Core flux from saturation density and area

Magnetic core data often mixes units. A ferrite manufacturer may give the saturation flux density in millitesla and the cross-sectional area in square millimeters, and the designer multiplies them to find the flux the core can carry. A core with an effective area of 25 mm², which is 0.000025 m², and a saturation density of 400 mT carries 0.4 T times 0.000025 m², or 0.00001 Wb. That is 0.01 mWb, which converts to 10 µWb. The numbers are illustrative and do not describe any real part. They show why microwebers are a convenient unit for small cores: the value 10 µWb is easier to remember and compare than 0.00001 Wb. The same step applies when you divide the flux by the number of turns to find volt-seconds per turn, or when you check that a simulated peak flux stays below the rated limit with some margin.

Integrating a voltage to get flux

A common measurement setup places a coil of known turns around a magnetic circuit and integrates the induced voltage over time. The flux change equals the integral of the voltage divided by the number of turns. If a 50-turn search coil shows a voltage pulse that integrates to 0.4 V·s, the result of 0.4 divided by 50 is 0.008 Wb. Smaller setups give numbers in the milliweber and microweber range. A 200-turn coil with an integrated signal of 0.0006 V·s corresponds to 0.000003 Wb, which is 3 µWb, or 0.003 mWb. Because one volt-second is one weber, no extra conversion factor appears in this calculation, and the milli and micro prefixes alone separate the readings. Keeping the integrator output units and the turn count written next to the result helps when numbers are later converted with this page.

Scope and sources

This page converts a known magnetic flux between two SI-prefixed units. It does not calculate flux from field and area, nor does it check installation limits, equipment ratings, protection requirements, material response such as core saturation, or compliance with any code or standard. Those depend on the specific equipment and the rules that apply where it is used. The unit definitions and prefix values come from the NIST guide to the SI and the SI Brochure of the International Bureau of Weights and Measures. If you need a result for a safety-related design, use the manufacturer data and the relevant standard, and treat this converter as a quick check on the arithmetic of the scale change.