Webers (Wb): magnetic flux unit guide

Wb is the reference unit for magnetic flux.

Measurement basis

A flux in webers already uses the reference scale.

Definition conventions

Maxwell uses the CGS EMU convention.

Conversion method

Keep Wb unchanged; divide by another flux factor for its notation.

Reference equivalent of Wb

1 Wb = approximately 1 Wb.

Recorded scale factors: 1 for Wb; 1 for Wb.

Worked example

Known input: 10 Wb. Reference equivalent: 10 Wb. The return conversion gives approximately 10 Wb.

The example retains a magnetic-flux amount.

Common reference values

Input (Wb)Reference equivalent (Wb)
11
55
1010
2525
5050
100100

Compare one Wb with other units

Target unitEquivalent of 1 WbDefinition guide
Milliwebers (mWb)1000Read definition
Microwebers (µWb)1000000Read definition
Nanowebers (nWb)1000000000Read definition
Maxwells (Mx)100000000Read definition
Picowebers (pWb)1000000000000Read definition

The weber as the SI measure of magnetic flux

The weber, symbol Wb, is the SI derived unit of magnetic flux. It is named after the German physicist Wilhelm Eduard Weber (1804 to 1891), who worked with Carl Friedrich Gauss on absolute measurements of magnetism. The SI Brochure gives it as a special name for the volt second, so 1 Wb = 1 V·s. It also equals one tesla times one square meter, 1 Wb = 1 T·m², and in base units kg·m²·s⁻²·A⁻¹. Flux is the amount of magnetic field passing through a surface: for a uniform field perpendicular to a flat area, flux equals flux density times area. Because both definitions lead to the same unit, you can check a calculation from either side.

Faraday induction links flux to volts

The volt second form is more than a bookkeeping identity. Faraday law of induction says the voltage induced in a loop equals the rate of change of flux through it, with a negative sign from Lenz law. A flux that changes by 1 Wb in 1 s induces 1 V in a single turn. With N turns the induced voltage is multiplied by N. For example, a coil of 100 turns in which the flux rises by 0.5 mWb in 10 ms produces 100 × 0.0005 / 0.01 = 5 V. The same relation explains why transformer designers specify peak flux in the core: for a given voltage and frequency, the flux is set by the winding, and the core must carry that flux without saturating.

Flux from field and area: a 25 cm² example

To get flux from a uniform field, multiply the flux density by the area it crosses at a right angle. A field of 0.2 T across a 25 cm² face, which is 0.0025 m², gives 0.2 × 0.0025 = 0.0005 Wb, or 0.5 mWb. If the face is tilted by an angle theta from perpendicular, multiply by the cosine of that angle, so a face turned 60 degrees passes half as much. Earth field of about 50 µT through a 1 m² loop gives roughly 50 µWb, while a 3 T MRI field across 0.05 m² corresponds to 0.15 Wb. A teslas figure alone is therefore not a flux, and an area is needed before comparing it with a value in webers.

Milliwebers to picowebers and the maxwell

Prefix steps are powers of ten: 1 Wb is 1,000 mWb, 1,000,000 µWb, 10⁹ nWb and 10¹² pWb. The site lists converters from Webers to Milliwebers, Microwebers, Nanowebers and Picowebers, plus Webers to Maxwells, each with a reverse direction. The maxwell, symbol Mx, is the CGS unit of flux, equal to one gauss times one square centimeter, so 1 Mx = 10⁻⁸ Wb and 1 Wb = 10⁸ Mx. The 0.5 mWb example above is 500 µWb or 50,000 Mx. Older magnetics literature, some ferrite and permanent magnet data sheets, and a few geophysics papers still use the maxwell, so a comparison with a modern source requires this conversion.

The flux quantum and the smallest flux scale

Superconducting devices work near an elementary flux scale. The magnetic flux quantum is h/(2e), where h is the Planck constant and e the elementary charge. Since the 2019 revision of the SI both are exact, so the quantum is about 2.067833848 × 10⁻¹⁵ Wb, roughly 2 femtowebers. A SQUID, a superconducting quantum interference device, responds to changes much smaller than one quantum, which is why such sensors detect very weak fields in biomagnetism and materials research. The weber has no more granular prefix on this site than the picoweber, so femtoweber values need exponent notation. The flux quantum also underlies the quantum Hall and Josephson voltage standards.

Flux linkage and weber-turns

A coil with N turns linking flux Φ has flux linkage N × Φ, often given in weber-turns and with the same dimension as the weber. Inductance is flux linkage per unit current: L = NΦ / I, in henries, and 1 H = 1 Wb/A. A 100 turn coil carrying 2 A whose core flux is 0.5 mWb has a linkage of 0.05 Wb-turns, and its inductance is 0.05 / 2 = 25 mH. In motor and generator data sheets, the permanent magnet flux linkage is a key parameter, and it is quoted in Wb or Vs. Check whether a quoted number is per turn or total, since a factor of N separates them and the unit label can look identical.

Confusions with tesla, gauss and the ampere-turn

Flux and flux density are separate quantities. The tesla is webers per square meter, and the gauss is the CGS version, with 1 T = 10,000 G. A magnet datasheet that lists 1.2 T remanence says nothing about total flux until the pole area is supplied. The maxwell is the flux counterpart of the gauss, and Mx/cm² is the same as a gauss. The ampere-turn measures magnetomotive force, which drives flux through a magnetic circuit as voltage drives current through an electrical one. Webers per ampere-turn is the permeance of the circuit. Wb is also easy to confuse with a lowercase wb, which is not a valid SI symbol, and with W for watts.

What a flux conversion leaves open

Changing from webers to milliwebers or maxwells restates a value that is already known. It does not give the flux a real part will carry, since that depends on material permeability, saturation, air gaps, temperature and the shape of the magnetic circuit. It cannot say whether a transformer, motor or sensor stays within its rating, and it does not replace a measurement with a calibrated fluxmeter or a Hall-probe survey. Keep the source of the number, the surface and its orientation next to the flux you publish, and convert only a value whose basis is clear.

A magnet pole face as an upper bound

A permanent magnet with a flux density of 1.2 T at a 2 cm² pole face, which is 0.0002 m², carries at most 1.2 × 0.0002 = 0.00024 Wb through that face, or 240 µWb. In maxwells that is 24,000 Mx. The figure is an upper bound because the field is not uniform across a real face, drops with distance from the magnet and leaks around it. In a magnetic circuit with an iron yoke, the flux through the gap is the flux in the yoke minus leakage. A ratio between pole flux and gap flux is called a leakage factor in magnet design texts, and it is typically supplied by the designer or measured. Without it, a flux obtained from field times area describes only the surface you chose.

Precision and checking

  • Keep source flux precision.
  • Retain Wb as the quantity label.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.