MEASUREMENT & METHODS

Volts (V): voltage unit guide

V is the reference unit for voltage.

Measurement basis

A volt reading already uses this group’s reference scale.

Definition conventions

The supported prefixes are SI decimal powers. The conversion rescales within the voltage quantity.

Conversion method

Keep V unchanged in the reference column. Divide by a target voltage factor to use another prefix.

Reference equivalent of V

1 V = approximately 1 V.

Recorded scale factors: 1 for V; 1 for V.

Worked example

Known input: 10 V. Reference equivalent: 10 V. The return conversion gives approximately 10 V.

The example retains the voltage quantity.

Common reference values

Input (V)Reference equivalent (V)
11
55
1010
2525
5050
100100

Compare one V with other units

Target unitEquivalent of 1 VDefinition guide
Millivolts (mV)1000Read definition
Microvolts (µV)1000000Read definition
Kilovolts (kV)0.001Read definition
Megavolts (MV)0.000001Read definition
Nanovolts (nV)1000000000Read definition
Picovolts (pV)1000000000000Read definition

One joule per coulomb

The volt, symbol V, is the SI derived unit of electric potential difference. One volt is the potential difference across which one coulomb of charge gains or loses one joule of energy. Equivalently, it is the difference between two points of a conductor carrying a constant current of 1 ampere when the power dissipated is 1 watt, so 1 V = 1 W/A = 1 J/C. In SI base units it is kg m² s⁻³ A⁻¹. The unit is named after Alessandro Volta, whose voltaic pile of 1800 was the first steady source of electric current. The International Electrical Congress in Paris adopted the volt, with the ohm and the ampere, in 1881.

How the volt is realized in a laboratory

Since the 2019 SI redefinition, the elementary charge and the Planck constant have exact values, which makes the Josephson constant K_J = 2e/h exact, about 483,597.85 GHz per volt. A Josephson junction irradiated by microwaves of frequency f develops voltage steps of n f / K_J. At 70 GHz one step is about 145 microvolts, and national laboratories connect thousands of junctions in series to reach 1 V and 10 V standards. Before 1990 laboratories kept groups of Weston saturated cells, and the volt was maintained by comparing them. Everyday voltmeters are calibrated by comparison with such references, so a multimeter reading can be traced back to the Josephson effect.

Prefix ladder from picovolts to megavolts

The site provides converters from volts to millivolts (V x 1,000), microvolts (V x 1,000,000), nanovolts, picovolts, kilovolts (V x 0.001) and megavolts, along with the reverse pairs. A 3.7 V cell is 3,700 mV. A thermocouple signal of 41 microvolts is 0.000041 V, and a distribution line at 11.5 kV is at 11,500 V. A peak of 325.3 V is 0.3253 kV, and a 0.5 mV signal is 500 microvolts or 0.0005 V. The prefix choice follows the signal: nanovolts and microvolts for sensors and amplifiers, millivolts for biological and audio signals, volts for electronics, kilovolts for power distribution and test equipment. Lowercase m means milli and uppercase M means mega, so mV and MV differ by a factor of 10^9.

Common voltages and what they refer to

A fresh alkaline AA cell has a nominal 1.5 V, and a lithium-ion cell is nominally 3.6 to 3.7 V and charges to 4.2 V. USB supplies 5 V in its basic profile. A lead-acid car battery is called 12 V and reads about 12.6 V when fully charged. Household outlets deliver a nominal 120 V in North America and 230 V across most of Europe under IEC 60038. High-voltage transmission operates from about 110 kV up to 765 kV and above. In the body, a neuron at rest sits near minus 70 mV across its membrane, and an electrocardiogram signal at the skin is on the order of 1 mV, so amplifiers handle a millionfold range of voltages.

RMS, peak and peak-to-peak

A voltage that alternates needs a statement of how it is measured. The nominal 120 V and 230 V of mains power are root-mean-square values, which produce the same heating as a direct voltage of that size. For a sinusoid the peak is the RMS multiplied by 1.4142, so 120 V RMS peaks at 169.7 V and 230 V RMS peaks at 325.3 V. The peak-to-peak value is twice the peak, 650.5 V for a 230 V supply. An oscilloscope shows peak-to-peak by default, while most multimeters show RMS. A conversion between volts and kilovolts changes none of these, so the form has to travel with the number.

Audio levels in dBV and dBu

Audio engineers express voltage on a logarithmic scale. The decibel relative to 1 V RMS is dBV, so 0 dBV is 1 V and minus 10 dBV, the consumer line level, is 0.316 V. The decibel relative to 0.7746 V RMS is dBu, a reference that comes from 1 mW in 600 ohms, so 0 dBu is 0.7746 V, and the professional line level of plus 4 dBu is 1.228 V. The two scales differ by about 2.2 dB, since 0 dBV equals 2.2 dBu. Treating a dB figure as plain volts, or the reverse, shows up as large errors in gain staging, and the scale label has to be known before any conversion.

Voltage is always between two points

A voltage is a difference, so a reading needs a reference. A battery terminal at 12 V is 12 V above its other terminal. A signal measured against ground can be 5 V while its difference from another signal is 0 V. Differential measurements remove the common reference, and some instruments are isolated so that their inputs float. Measuring a high voltage safely depends on equipment ratings and procedures that no unit converter provides. The conversion pages change the unit of a reading that has already been taken and do not infer how it was measured, whether the circuit was loaded, or whether the equipment was rated for it.

Relating volts to current, resistance and power

Volts connect to other electrical units through Ohm law and the power relation. A 12 V supply across a 6 ohm load drives 2 A, and the power is 12 x 2 = 24 W. A 230 V circuit carrying 10 A delivers 2,300 volt-amperes, and with a power factor of 0.8 the real power is 1,840 W. Dropping the supply to 120 V with the same 2,300 VA gives 19.2 A. Voltage alone does not say how much current or power is involved, which depends on the load. These relations are the reason the site separates voltage, current, resistance and power into separate converter families.

Symbol, quantity symbols and spelling

The unit symbol V is capitalized because the unit honors a person, and the written name volt is lowercase. The quantity symbol is also V or U, and E is used for electromotive force, which leads to expressions such as V = 12 V that look odd but are standard, since the italic V is the quantity and the upright V the unit. A space separates the number and the unit, as in 230 V. The plural is volts. Some older texts write KV for kilovolts, which does not follow SI, and the correct symbol is kV. Keep the case consistent in tables, because the converter and later readers treat case as meaningful.

Precision and checking

  • Keep source voltage precision.
  • Preserve any measurement convention from the source.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →