MEASUREMENT & METHODS

Picovolts (pV): voltage unit guide

pV is the pico-prefixed voltage entry.

Measurement basis

The stored scale is 10^-12 V per pV.

Definition conventions

The supported prefixes are SI decimal powers. The conversion rescales within the voltage quantity.

Conversion method

Multiply pV by 10^-12 for the reference.

Reference equivalent of pV

1 pV = approximately 1e-12 V.

Recorded scale factors: 1e-12 for pV; 1 for V.

Worked example

Known input: 10 pV. Reference equivalent: 1e-11 V. The return conversion gives approximately 10 pV.

The tiny volt value preserves the source quantity.

Common reference values

Input (pV)Reference equivalent (V)
11e-12
55e-12
101e-11
252.5e-11
505e-11
1001e-10

Compare one pV with other units

Target unitEquivalent of 1 pVDefinition guide
Volts (V)1e-12Read definition
Millivolts (mV)1e-9Read definition
Microvolts (µV)0.000001Read definition
Kilovolts (kV)1e-15Read definition
Megavolts (MV)1e-18Read definition
Nanovolts (nV)0.001Read definition

A voltage far below instrument noise

The picovolt, symbol pV, is 10⁻¹² volt. The volt is the SI unit of electric potential difference, equal to one joule per coulomb, or one watt per ampere, and in base units it is kg·m²·s⁻³·A⁻¹. A picovolt is smaller than the thermal noise voltage of ordinary resistors in any practical bandwidth. A 1 kΩ resistor at 300 K has a noise density of about 4.07 nV/√Hz, which is 4,070 pV/√Hz, so a signal of one picovolt is far below it. Measurements at this level need low-resistance sources, cooling, narrow bandwidths and averaging, and most of the numbers quoted in picovolts are noise densities, resolutions or the output of specialist sensors, and not signals measured directly. A voltage divider shows the idea: a 1 V source divided by a ratio of 10¹² would give 1 pV, but the resistors involved would be so large that their own noise would swamp the output.

Thermal noise in picovolts

Johnson noise, the voltage fluctuation of a resistor, has a spectral density of the square root of 4kTR per hertz, where k is the Boltzmann constant. A 50 Ω resistor at 300 K gives about 0.91 nV/√Hz, which is 910 pV/√Hz. Cooling a 1 kΩ resistor to 4.2 K, the boiling point of liquid helium at normal pressure, lowers the density to about 0.48 nV/√Hz, which is 480 pV/√Hz. In a 1 Hz bandwidth those are the rms voltages, so the picovolt scale appears when resistances are small and temperatures are low. The Boltzmann constant is fixed exactly at 1.380649 × 10⁻²³ J/K in the 2019 SI, which makes these relations a definite calculation and not an estimate. A 1 MΩ resistor at 300 K would give 128.7 nV/√Hz, and a 10 Ω part 0.407 nV/√Hz, which shows how directly resistance sets the picovolt floor.

Thermoelectric voltages and the nanovoltmeter

Dissimilar metals produce a thermoelectric voltage when their junctions are at different temperatures, which is the Seebeck effect. A type K thermocouple gives about 41 µV per kelvin, so a temperature difference of 1 mK yields 41 nV, and a signal of 1 pV would correspond to roughly 24 nK. Copper to copper contacts can still generate nanovolts from small temperature gradients, which is why low-level measurements use matched materials and thermal shielding. A good nanovoltmeter has a resolution of 1 nV, and reaching down to picovolts requires lock-in amplifiers, SQUID-based amplifiers or long averaging. The picovolt figure then refers to the signal after averaging, and the averaging time must be part of the specification.

The volt, Josephson standards and the 2019 SI

The modern realization of the volt uses the Josephson effect. Since 2019, the SI fixes the elementary charge and the Planck constant, which define the Josephson constant K_J = 2e/h at about 483,597.8484 GHz/V. A junction irradiated at frequency f develops voltage steps of f divided by K_J, and an array of junctions at 70 GHz produces about 144.7 µV per junction per step, since 70 × 10⁹ divided by 4.836 × 10¹⁴ is 1.447 × 10⁻⁴ V. Voltages on the picovolt scale are tiny fractions of these steps. National laboratories keep the volt with a relative uncertainty of a few parts in 10⁹ or better, which is why even a picovolt-level comparison is a statement about a ratio and not an absolute definition.

Ladder of voltage prefixes

The Computandum voltage converters step the unit in both directions. Volts to Picovolts multiplies by 10¹², Millivolts to Picovolts by 10⁹, Microvolts to Picovolts by 10⁶ and Nanovolts to Picovolts by 1,000. Kilovolts to Picovolts multiplies by 10¹⁵ and Megavolts to Picovolts by 10¹⁸. Going down, Picovolts to Nanovolts multiplies by 0.001, Picovolts to Microvolts by 10⁻⁶, Picovolts to Millivolts by 10⁻⁹ and Picovolts to Volts by 10⁻¹². A reading of 480 pV is therefore 0.48 nV and 4.8 × 10⁻¹⁰ V. The large factors, such as 10¹⁸ for megavolts, are the reason scientific notation is the clearest way to show these results.

Bio-signals and cryogenic electronics

Neural spikes recorded outside a cell are tens to hundreds of microvolts, so picovolts are far below biological signals except in noise budgets. Amplifier input noise is specified as nV/√Hz, and low-noise designs reach about 1 nV/√Hz or below, which is 1,000 pV/√Hz. Cryogenic amplifiers in radio astronomy and quantum computing readouts reach lower noise because the source resistance and temperature fall together. A noise density of 500 pV/√Hz over a 1 MHz bandwidth integrates to 0.5 µV rms, since the bandwidth multiplies the noise by the square root of one million. This shows why a seemingly tiny density still matters, and why bandwidth is part of every noise statement.

Symbol confusion with PV and pV

The two letters pV have other meanings. In photovoltaics, PV means solar cells, and capital letters distinguish them from the unit. In thermodynamics, p times V, pressure multiplied by volume, appears in expressions such as pV = nRT and has units of energy. The picovolt is written with lowercase p and capital V, from the name of Alessandro Volta. Capital PV for the unit is wrong, because P is the prefix for peta, so PV would be petavolt, 10¹⁵ V, a quantity no instrument measures. A line such as pV = 0.5 could be a gas law term or a voltage, and the dimension of the quantity tells which. When reading mixed text, check the units attached to the number and the surrounding symbols.

Reporting a picovolt result

A picovolt measurement should state the bandwidth, the source resistance, the temperature and the averaging time. A noise density quoted in pV/√Hz cannot be compared with a value in pV rms without knowing the bandwidth. Conversions to volts only change scale. A value of 480 pV is 4.8 × 10⁻¹⁰ V and keeps two significant digits. Drifts of thermoelectric offsets, input bias currents flowing through source resistances and electromagnetic interference all contribute to a floor above what the thermal calculation gives. A result that claims a precision below that floor deserves skepticism. Contact potentials between a probe tip and a sample, which are often millivolts, can be thousands of times larger than the signal, so differential measurements and chopping are used to cancel them. Writing down the instrument, its range and the cable arrangement makes the number reproducible, which is the real test of a very small voltage. A result obtained once on a quiet night in a screened room is a different kind of evidence from a value that repeats after the equipment is disconnected and rebuilt.

Precision and checking

  • Keep measured voltage resolution.
  • Avoid early rounding to zero.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →