Measurement basis
The stored scale is 1,000,000 V per MV.
Definition conventions
The supported prefixes are SI decimal powers. The conversion rescales within the voltage quantity.
Conversion method
Multiply MV by one million to read volts, keeping the source label’s case.
Reference equivalent of MV
1 MV = approximately 1000000 V.
Recorded scale factors: 1000000 for MV; 1 for V.
Worked example
Known input: 10 MV. Reference equivalent: 10000000 V. The return conversion gives approximately 10 MV.
The large volt result follows the mega definition.
Common reference values
| Input (MV) | Reference equivalent (V) |
|---|---|
| 1 | 1000000 |
| 5 | 5000000 |
| 10 | 10000000 |
| 25 | 25000000 |
| 50 | 50000000 |
| 100 | 100000000 |
Compare one MV with other units
| Target unit | Equivalent of 1 MV | Definition guide |
|---|---|---|
| Volts (V) | 1000000 | Read definition |
| Millivolts (mV) | 1000000000 | Read definition |
| Microvolts (µV) | 1000000000000 | Read definition |
| Kilovolts (kV) | 1000 | Read definition |
| Nanovolts (nV) | 1000000000000000 | Read definition |
| Picovolts (pV) | 1000000000000000000 | Read definition |
One million volts
A megavolt (MV) is 1,000,000 volts. The volt is the SI unit of electric potential difference, named for Alessandro Volta, and equals one joule per coulomb, or 1 V = 1 W/A. In the SI revised in 2019, the volt is realized through the Josephson effect with the Josephson constant 2e/h, fixed at about 483,597.848 GHz per volt. The site lists converters between megavolts and volts, kilovolts, millivolts, microvolts, nanovolts and picovolts. The factors are 1 MV = 1,000 kV = 10⁶ V = 10⁹ mV = 10¹² µV. The megavolt describes potentials found in particle accelerators, lightning, high-voltage testing and the longest power transmission lines, all well above the few hundred volts of household systems.
Transmission lines and ultra-high voltage
Power networks use kilovolts for most lines, with 765 kV (0.765 MV) in use in North America and 1,000 kV AC lines operating in China since 2009. The Changji to Guquan DC link, commissioned in 2019, runs at 1,100 kV, which is 1.1 MV and one of the highest operating voltages in service. Higher voltage cuts losses for the same power, because current falls as voltage rises: delivering 1,000 MW at 1 MV needs 1,000 A, and at 100 kV it needs 10,000 A. Resistive loss varies with the square of current, so the 100 kV case wastes 100 times more in the same conductor. Insulators and tower clearances grow with voltage, which makes line cost rise with the level chosen.
Lightning, breakdown and test equipment
A thundercloud can reach potentials of tens to hundreds of megavolts relative to ground. Air breaks down at about 3 MV/m in a uniform field under standard conditions, so a perfect 1 MV gap would be about 0.33 m wide, although real electrodes with points need larger spacings. Impulse generators, called Marx generators, charge capacitors in parallel and discharge them in series to build megavolt pulses. Standards such as IEC 60060-1 define the standard lightning impulse as a 1.2/50 µs wave, with 1.2 µs rise time and 50 µs decay to half value. Utilities and manufacturers test insulators, bushings and transformers with these pulses to confirm withstand levels.
Accelerators and medical X-ray beams
An electron gaining energy across a potential difference of 1 MV acquires 1 MeV, so the numbers match when energy is stated in electronvolts. Tandem and Van de Graaff accelerators work at several megavolts, with some tandem machines near 25 MV. Radiotherapy linear accelerators are described by their photon beam energy in MV, such as 6 MV or 18 MV, where the value refers to the peak accelerating potential and the photons have a spectrum below that. Diagnostic X-ray tubes work at 20 to 150 kV, which is 0.02 to 0.15 MV. Accelerator cavities are also rated by electric field gradient: the ILC design called for about 31.5 MV/m, giving 31.5 MV over a meter of cavity. Field and voltage are different quantities.
Worked conversions and current
Convert between prefixes by powers of 1,000. A 765 kV line is 0.765 MV, a 500 kV line is 0.5 MV, and 2.5 MV is 2,500 kV or 2,500,000 V. In millivolts, 1 MV is 1,000,000,000 mV. Ohm's law links voltage to current and resistance: 1 MV across a 100 MΩ insulator drives 0.01 A, which is 10 mA. Electrical power is voltage times current, so 1 MV at 1 A is 1 MW. A discharge of 100 kA at an assumed 100 MV during a lightning stroke would be 10 TW instantaneous, though real strokes last microseconds and the actual figures vary widely. Use the conversion for notation, and use the physical relations for anything about power or energy.
MV does not always mean megavolt
In power engineering, MV is the standard abbreviation for medium voltage, a range above low voltage and below high voltage, typically from 1 kV up to about 35 kV or so depending on the standard. A medium-voltage switchgear panel on a 11 kV or 33 kV network is a thousand times lower than a megavolt. The context usually resolves which meaning applies, but searching a document for MV can mix them. Digital forms print megavolt with a capital M and capital V, and medium voltage uses the same letters, so the surrounding units, such as kV in the same table, help. If a rating line reads 15 MV on a distribution component, it is almost certainly a typo or a medium-voltage class label, not a megavolt value.
Preserve case during transcription
A lowercase m denotes milli, so mV is a thousandth of a volt, and a megavolt differs from it by a factor of 10⁹. Copying MV into a system that forces lowercase changes a lightning-test result into a signal-level value. The symbol stays MV for both singular and plural, so 3 MV is correct. Write the quantity name with the symbol on first use if the document might be read by someone outside the field. For tables, keep prefix case when sorting or exporting, because spreadsheet functions sometimes normalize text. A conversion tool maps MV to V by multiplying by 1,000,000, but it cannot detect that a typed value came from a lowercase source symbol, so review the original before converting.
Voltage is potential difference, not energy or power
A megavolt rating says how much potential difference exists between two points. It does not say how much energy can be delivered, which depends on the charge or current available. A static spark from a charged person can exceed 10 kV yet carry a few millijoules, while a 400 V battery bank can deliver far more energy. Voltage also does not describe the electric field, which depends on distance: the same 1 MV is a field of 1 MV/m across a meter and 1,000 MV/m across a millimeter. High voltage also stays hazardous even at tiny currents when insulation fails, and work on such equipment follows strict procedures and trained personnel. The unit conversion supports record keeping and does not replace those controls.
Standards that name the megavolt
Insulation coordination standards group equipment into voltage classes and test levels. IEC 60071 deals with insulation coordination, and its highest equipment voltages for AC systems extend past 1,000 kV, which is the megavolt range. Test laboratories rate impulse generators by their total voltage, such as 2.4 MV or 6 MV, and by stored energy in kilojoules. A generator of 6 MV with stages of 200 kV each would need 30 stages in series, since 6,000 kV divided by 200 kV is 30. Reading a catalog entry therefore involves three numbers: voltage, stored energy and wave shape. Only the first is in megavolts, and the energy figure in kJ or MJ is what drives the size of the capacitors.
Precision and checking
- Keep original voltage precision.
- Retain uppercase M.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Voltage converter
- Megavolts to Volts converter
- Megavolts to Millivolts converter
- Megavolts to Microvolts converter
- Megavolts to Kilovolts converter
- Megavolts to Nanovolts converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.
Sources
- NIST / BIPM: Voltage: reference unit definitions ↗ · 2026-10-08