MEASUREMENT & METHODS

Voltage: units and measurement guide

Voltage describes an electric potential difference.

Measurement basis

Changing voltage units does not calculate power, insulation requirements or installation conditions.

Definition conventions

The supported prefixes are SI decimal powers. The conversion rescales within the voltage quantity.

Conversion method

Apply the compatible voltage-factor ratio while retaining the source conditions separately.

Choose the conversion direction

Start with the full voltage symbol on the measured value and choose the required target scale.

Electric potential difference and the volt

Voltage is the electric potential difference between two points. One volt is the potential difference across which one coulomb of charge gains or loses one joule of energy, so 1 V = 1 J/C. In terms of base units it equals 1 kg·m²·s⁻³·A⁻¹, and it also equals one watt per ampere, which is why P = V × I links power, voltage and current. The unit is named after Alessandro Volta, who built the first chemical battery around 1800. Voltage always refers to a pair of points: a reading of 12 V means 12 V between the probes, not a property of one terminal alone.

How the volt is realized in a laboratory

Since the 2019 SI revision, the volt follows from the fixed values of the Planck constant and the elementary charge. In practice, national metrology institutes realize it using the Josephson effect, where a superconducting junction driven by microwaves produces voltages proportional to the frequency, with a factor involving 2e/h. From 1990 until 2018 a conventional value of the Josephson constant, 483,597.9 GHz/V, was used worldwide to keep calibrations consistent, and the 2019 change made the exact constant available directly. Everyday multimeters trace their accuracy to these laboratory standards through calibration chains, and their typical uncertainty is many orders of magnitude larger than the standard itself.

From microvolts to megavolts

The SI prefixes cover a very wide range. One volt equals 1,000 mV, and 1 mV equals 1,000 µV, so 1 V is 1,000,000 µV. Going up, 1 kV is 1,000 V and 1 MV is 1,000,000 V. A thermocouple produces tens of microvolts per kelvin, so a 4.2 mV output is 4,200 µV. An electrocardiogram signal is around 1 mV at the skin. A 68 kV X-ray tube setting is 68,000 V. Capital and lowercase letters carry meaning: mV is a thousandth of a volt, while MV is a million volts, a ratio of 10⁹. A misplaced capital in a handwritten note or a sensor label produces an error of that size.

Familiar voltages and the ranges they sit in

A single alkaline AA cell provides about 1.5 V, a lithium-ion cell about 3.6 to 3.7 V nominal, and a car lead-acid battery 12 V nominal. USB power starts at 5 V. Mains electricity is 120 V in North America and 230 V across much of Europe, as nominal RMS values. Overhead transmission lines operate from tens of kilovolts to several hundred kilovolts, with some links above 700 kV. Lightning involves potential differences that are commonly described as of the order of 100 MV. Neurons at rest hold a membrane potential near minus 70 mV. Power over Ethernet sources supply roughly 44 to 57 V, and USB Power Delivery profiles run from 5 V up to 20 V.

RMS, peak and peak-to-peak for alternating voltage

A voltage that alternates needs a statement of how it is measured. For a sine wave, the RMS value equals the peak divided by the square root of 2. A 120 V RMS outlet reaches a peak of about 169.7 V, and a 230 V RMS supply peaks at about 325.3 V. The peak-to-peak value is twice the peak, roughly 339.4 V for the 120 V supply. A conversion from V to kV or mV works on any of these, but you must not change from RMS to peak by changing the unit. The factor of 1.4142 holds for sine waves only, since a square wave has an RMS value equal to its peak.

Decibel forms such as dBV and dBµV

Audio and radio engineers often express voltage as a level in decibels relative to a reference. The unit dBV is 20 times the base-10 logarithm of the voltage divided by 1 V, so 1 V is 0 dBV, 0.1 V is minus 20 dBV and 2 V is about 6.02 dBV. Professional audio line level of +4 dBu corresponds to 1.228 V RMS, with dBu referenced to 0.7746 V. In receiver specifications, dBµV is relative to 1 µV, and 60 dBµV equals 1 mV. These are logarithmic levels, not linear voltages, so you cannot convert them to volts by multiplying by a factor. You need the reference and the formula.

EMF, potential difference and voltage drop

Several terms share the volt. Electromotive force, or EMF, is the energy per charge supplied by a source such as a battery with no current flowing. The terminal voltage is lower when current flows, because the internal resistance drops some of it. A drop across a resistor equals current times resistance, so 2 A through 0.5 Ω produces 1 V. Voltage drop across a long cable is a design concern that reduces the voltage reaching a load. All of these are measured in volts, and conversions between V, mV and kV apply equally to each, but the physical meaning differs. A 12 V battery with 0.05 Ω of internal resistance that delivers 20 A has a terminal voltage of 12 − 20 × 0.05 = 11 V.

What a unit conversion cannot tell you

A voltage converted to kilovolts is still a potential difference and nothing more. Whether equipment, insulation or a circuit can handle it depends on current, frequency, spacing, altitude, humidity, materials and the standard that applies. Safety limits and classes, such as extra-low voltage or low voltage, are set in standards from bodies such as the IEC and national authorities, and their thresholds differ for AC and DC. A conversion helps you read a rating written in a different prefix, for example 0.4 kV equals 400 V, but it does not establish a safe working practice. IEC 60038 lists the standard nominal supply voltages, such as 230/400 V for three-phase low-voltage systems in Europe.

Batteries in series and divided voltages

Voltages add when sources are connected in series. Four AA cells at 1.5 V give 6 V, and a lithium-ion pack of 10 cells at 3.7 V nominal gives 37 V, written 0.037 kV. Cells in parallel keep the voltage of one cell and add capacity. A resistive divider with 9 kΩ above 1 kΩ passes one tenth of the input to the output, so a 5 V input produces 0.5 V, or 500 mV. These examples show why the prefix matters: an ADC with a 3.3 V reference and a sensor that outputs millivolts need the same quantity written in matching units before any calculation is done. A 10-bit converter with a 3.3 V reference resolves steps of 3.3 / 1,024, about 3.22 mV, so a 1 mV sensor signal falls below one step without amplification.

Precision and checking

  • Retain the source voltage resolution.
  • Capitalization distinguishes milli and mega scales.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Choose a unit definition

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →