Meter readings and device specs
A multimeter on a millivolt range reports a small DC value, while the device you are testing is specified in volts: a battery at 1.5 V, a USB port at 5 V, a car battery at about 12.6 V. A voltage drop test on a fuse or a connector gives millivolts that must be compared with a specification in volts, and a current shunt marked 75 mV is described in a manual that talks about volts of supply. This page divides the millivolt value by 1,000 and shows volts. People who use it include car owners checking wiring, electronics hobbyists reading datasheets, electricians verifying instrument ranges and students doing a first circuit lab.
Reading 450 mV as 0.45 V
The prefix milli means 10^-3, so 1 mV equals 0.001 V and the page divides by 1,000. The volt is the SI unit of electric potential difference, one joule per coulomb as defined in the BIPM SI Brochure, and the prefix is defined, so there is no uncertainty. Mentally, move the decimal point three places to the left. A reading of 450 mV is 0.45 V and 3,300 mV is 3.3 V. In the other direction, 0.45 V is 450 mV. If the result is larger than the input, the units were chosen the wrong way. The page also lists microvolts, kilovolts, megavolts, nanovolts and picovolts.
Ten millivolts in volts
The default of 10 mV gives 0.01 V. A reading of 12,600 mV on a car battery is 12.6 V, a pair of AA cells at 3,000 mV is 3 V, and a single alkaline cell at 1,500 mV is 1.5 V. A small signal of 250 mV is 0.25 V. The round conversions to volts show why a display in millivolts is common on the smallest ranges but rarely used for supply voltages. A value in the thousands of millivolts is more readable as volts, and a value below 100 mV is more readable as millivolts, so pick the unit that keeps the number between about 1 and 1,000.
Voltage drop tests on fuses and connectors
A common diagnostic in vehicles and electrical panels is to measure the voltage across a fuse, a switch or a connector while it carries current. A good fuse carrying its load drops only a small voltage. If a meter on its 200 mV range reads 85 mV across a fuse, that is 0.085 V. A reading of 450 mV across a connector that carries a load would be 0.45 V and would point to a poor contact, because that drop wastes power and heats the part. The acceptable drop depends on the circuit and the guidance of the manufacturer, so use the service manual. The conversion helps you compare the reading with a limit written in volts.
Current shunts rated in millivolts
Panel meters and battery monitors use shunt resistors that are rated by a current and a millivolt drop, for example 100 A at 75 mV. The resistance is 0.075 V divided by 100 A, which is 0.00075 ohm, or 0.75 milliohm. If the monitor reads 30 mV across such a shunt, the current is 30 / 75 × 100 = 40 A. The power dissipated at full rating is 0.075 V times 100 A, or 7.5 W. The page converts the 75 mV rating to 0.075 V, which makes these calculations easy. The actual accuracy depends on the shunt tolerance and temperature, which are in its data sheet.
Battery and logic levels
Digital logic and sensors list thresholds in volts or millivolts, such as a 3.3 V supply with an input-low limit of 0.8 V. A level of 800 mV is 0.8 V. Battery voltage ranges are quoted in volts, but a protection circuit may trip at a few millivolts below a limit. A single lithium-ion cell charges to 4.2 V and a typical cutoff on discharge is around 3.0 V or higher depending on the maker, values that are 4,200 mV and 3,000 mV. The page converts quickly between the two forms, which helps when a firmware setting is entered in millivolts and a datasheet is written in volts.
Converting volts back to millivolts
To go the other direction, select volts as the source and millivolts as the target. A value of 0.45 V equals 450 mV, 1.5 V equals 1,500 mV and 5 V equals 5,000 mV. The page multiplies by 1,000. A frequent slip is to type 0.5 in a millivolt field when the value is 0.5 V, which would be a thousand times too small. Check the unit label of each field before reading the output. which would be a thousand times too small. Check the unit label of each field before reading the output, and test the page with a value you already know, such as 1,500 mV for a single alkaline cell, before trusting a long list of conversions. Firmware and microcontroller code often use integers in millivolts so that no decimal point is needed, and a quick conversion helps confirm that a constant of 3300 means 3.3 V.
Meter range, resolution and accuracy
A handheld meter on a 200 mV range might resolve 0.1 mV, and a reading such as 85.3 mV carries three digits. Its accuracy is quoted as a percentage of the reading plus a number of counts, so the last digit may not be reliable. Quote the converted value with the same digits: 0.0853 V, not 0.085300 V. When the meter jumps between ranges, do not assume the display unit. A display of 0.085 means volts on a volt range and 0.085 mV is a different reading. Check the unit annunciator on the screen, and note the range along with the value.
Why a converted reading is not a diagnosis
The page converts a voltage between prefixes. It does not diagnose a circuit, say whether a reading is acceptable, compute current from a shunt or judge electrical safety. Interpretation depends on the circuit, the specifications and the rules that apply to the work, and anything involving mains or high-energy systems should be done by qualified people following local requirements. and anything involving mains or high-energy systems should be done by qualified people following local requirements. If a reading looks odd, compare it with a second meter before blaming the circuit, and check the battery of the meter itself, since a weak battery can shift low-range readings.