Noise floors and signals in the same table

A signal chain for a thermocouple, a strain gauge bridge or an EEG headset has signals of microvolts and amplifier noise stated in nanovolts or picovolts. To judge whether the noise matters, both have to be on one scale. This page multiplies a picovolt value by 10^-6 and returns microvolts. The shift is six decimal places, which makes hand conversion prone to slips, and the result for a typical noise figure is a small decimal that the page shows in scientific notation. The point of the tool is to keep the exponent visible so a copied figure does not change by a factor of ten. Both numbers belong in the same row of a noise budget, with the bandwidth noted beside them.

A million picovolts in a microvolt

Pico is 10^-12 and micro is 10^-6, so one microvolt equals 10^6 picovolts. The formula is µV = pV × 1e-6, and the factor is exact because both prefixes are fixed powers of ten. A voltage of 3 pV is 3 × 10^-6 µV, 500,000 pV is 0.5 µV, and 41,000,000 pV is 41 µV. The volt is one joule per coulomb, and the SI Brochure defines the prefixes. On paper, the decimal moves six places to the left. Check one reference case before relying on a list of results: 1 µV must give 1,000,000 pV. The reverse also holds: 0.001 µV is 1,000 pV, which equals 1 nV.

Ten picovolts in microvolt terms

The default value of 10 pV gives 1 × 10^-5 µV. Few instruments resolve voltages that small. Thermal noise in a resistor alone exceeds it in any real bandwidth: a 1 kΩ resistor at room temperature produces about 4 nV per square root of hertz, so even in a bandwidth of 1 Hz the noise is 4,000 pV. The result shows why picovolt-level measurement needs special techniques such as cooled sources, lock-in detection and long averaging. If the output is larger than your input, the units were entered in the wrong order, since the microvolt is the larger unit.

Thermocouple outputs in microvolts

A type K thermocouple produces about 41 µV per degree Celsius near room temperature. A change of 1 degree is 41 µV, which equals 4.1 × 10^7 pV, and a change of 0.01 degree is 0.41 µV, or 410,000 pV. A meter with a noise of 0.2 µV, equal to 200,000 pV, resolves about 0.005 degree. These figures show how amplifier noise limits temperature resolution. The conversion helps to compare datasheet noise in pV or nV with the thermocouple sensitivity in µV per degree, although the page itself does not compute temperature and does not apply the nonlinear tables. An error of 1 degree in the reference junction shifts the reading by the same 41 µV, so reference junction compensation matters more than amplifier noise.

Scalp EEG and the amplifier behind it

Scalp EEG signals are in the range of tens of microvolts, and an alpha rhythm of 20 µV equals 2 × 10^7 pV. Amplifier input noise is typically specified as a fraction of a microvolt over the band of interest, perhaps 0.5 µV peak-to-peak or less. That is 500,000 pV, a small fraction of the signal. Electrode contact, mains interference and muscle activity add far more error than the amplifier does. The conversion is a way to read a datasheet in the same unit as a clinical or research paper, while the quality of a recording depends on skin preparation and shielding. For orientation, 100 µV is 10^8 pV, still far above the picovolt scale.

Thermal voltages in a low-level circuit

Any junction of two different metals creates a small thermoelectric voltage when its temperature differs from the surroundings. Ordinary tin-lead solder against copper can produce a few microvolts per degree, which is millions of picovolts, enough to swamp a measurement of a smaller signal. Low-level designers choose special solders, keep junctions at equal temperature and avoid air currents. A change of one degree across a junction giving 2 µV equals 2,000,000 pV, which dwarfs the noise of a good amplifier. The page converts the numbers and leaves the circuit design to you. Keep leads of one metal pair together and shielded from drafts, so that both junctions see the same temperature.

Going from microvolts to picovolts

To convert in the other direction, choose microvolts as the source and picovolts as the target. One microvolt is 10^6 pV, 41 µV is 4.1 × 10^7 pV, and 0.5 µV is 500,000 pV. A datasheet that lists an offset in microvolts and a drift in picovolts per hour or per degree needs this step to compare the two. Because the results run to millions or billions, scientific notation is the clearest format. Keep the unit symbol next to each number, and check that the first digits of the result match the first digits of the input. The same holds for small values: 0.002 µV is 2,000 pV.

Writing µV so it is not misread

The Greek letter mu is not available on every keyboard, and many sheets write uV instead, which can be mistaken for a typo or for another symbol. Use µV where possible and spell out microvolts in headers. The symbol pV has a lowercase p and a capital V, and a lowercase pv can mean present value in finance. In a mixed table, a column header with the full unit name stops such confusion. Review pasted values in a spreadsheet, because a cell format can strip an exponent and turn 1E-5 into text or a different number. Exporting data as plain numbers with the unit in the header avoids most of these problems, and it keeps the table readable by anyone who opens it later.

Questions about the voltage itself

The page converts a voltage and cannot say whether the voltage came from signal or noise, whether it was measured with the right bandwidth or whether an instrument was calibrated. Voltage noise depends on the bandwidth and source resistance, and an offset depends on temperature and time. The factor is exact, so a result that looks wrong most likely comes from a mistyped exponent or a swapped unit. Compare with the anchor value, 1 µV giving 10^6 pV, and read the unit symbols on the source before looking for another explanation. If you pass the value on to a colleague, give the bandwidth and the source resistance with it, since a noise voltage without them cannot be compared with another datasheet.