Eighteen decades in one table
Voltage spans a vast range in practice. A low-noise amplifier is judged by a noise floor of nanovolts or picovolts, while a transmission line, a substation or an impulse test set operates at hundreds of kilovolts or megavolts. A report on instrumentation, a course on measurement or a table of ranges might list both ends. This page multiplies a picovolt value by 10^-18 and returns megavolts. The answer is extremely small and is shown in scientific notation, which prevents a long string of zeros from hiding an error of several orders of magnitude when the figures are copied between documents. A table might list a 10 pV noise figure, an 11 kV distribution line and a 765 kV transmission line, which spans seventeen powers of ten from end to end.
The factor of ten to the eighteenth
Pico is 10^-12 and mega is 10^6, so one megavolt equals 10^18 picovolts, a quintillion. The formula is MV = pV × 1e-18, and the factor is exact because both prefixes are defined powers of ten in the SI Brochure. A voltage of 4 × 10^17 pV is 0.4 MV, which is 400 kV, and a voltage of 5 pV is 5 × 10^-18 MV. The volt is one joule per coulomb, or one watt per ampere. By hand, move the decimal eighteen places to the left, or divide by 10^12 to get volts and then by 10^6 to get megavolts.
Ten picovolts against a megavolt
Entering 10 pV gives 1 × 10^-17 MV. A written-out decimal would have sixteen zeros after the point, which nobody reads reliably, so the exponent form is the clear choice. The result illustrates the spread of electrical practice: ten picovolts is far below the thermal noise of any resistor in a typical circuit, and a megavolt is the order of the test voltage for insulators in the largest high-voltage laboratories. If the answer is larger than your input, the units were selected in the wrong order, because the megavolt is the larger unit. Dividing 10 by 10^18 gives 10^-17, which is the figure the page returns.
Transmission voltages in megavolts and picovolts
High-voltage lines are rated in kilovolts, and the highest classes are given in fractions of a megavolt. A 765 kV line is 0.765 MV, which is 7.65 × 10^17 pV, and a 400 kV line is 0.4 MV. Distribution at 11 kV is 0.011 MV, and a 132 kV subtransmission line is 0.132 MV. Writing them in megavolts puts the bigger systems on a scale close to one. Writing them in picovolts is not practical, but the conversion supports a table that spans measurement and power in one unit. Use the kilovolt form for ordinary documents and keep the megavolt for the largest systems. A drawing that lists 0.4 MV is unusual, so this page matters mostly when a study ranks very different voltages in a single list.
Impulse test sets and the voltages they produce
Insulation tests on transformers, bushings and switchgear use impulse generators that produce short pulses of hundreds of kilovolts, and large laboratories reach a few megavolts. A 2 MV test pulse is 2 × 10^18 pV, and the same test measures the resulting waveform with dividers that bring the signal down to a few volts for an oscilloscope. The test standards describe waveshape and tolerance, and the converter has no part in those. The conversion helps when a course or a report compares the test voltage with the smallest voltage that an instrument can resolve in a different lab. Rating plates on such equipment give the peak voltage and the waveshape, and neither changes with the unit you choose.
Dynamic range in decibels
The ratio between 1 MV and 1 pV is 10^18, which in amplitude terms is 20 × log10(10^18), or 360 dB. Instrument makers rate dynamic range in decibels or in bits. A 24-bit converter spans about 144 dB in ideal terms, a long way below 360 dB. No single instrument covers the whole range, so measurements at the two ends use completely different equipment, such as a nanovoltmeter on one side and a resistive or capacitive divider on the other. Expressing both in megavolts or picovolts is a way to see that gap instead of describing it loosely. A 16-bit converter covers about 96 dB, and a 24-bit one about 144 dB, both far short of 360 dB.
From megavolts to picovolts
Choose megavolts as the source and picovolts as the target to convert in the other direction. One megavolt is 10^18 pV, 0.765 MV is 7.65 × 10^17 pV, and 2 MV is 2 × 10^18 pV. A number of this size does not fit in a 32-bit integer and exceeds the exact range of a 64-bit floating point value, so software that stores everything in picovolts needs care. If you build such a table, check one reference value, for example 1 MV returning 10^18 pV, and store the exponent explicitly rather than a long string of digits. Enter a value such as 0.011 MV with its decimal point, and keep the megavolt unit selected, so the result stays consistent with the rest of the table.
Reading kilovolt and megavolt labels
Equipment labels and drawings mix kV and MV, and the symbols differ in case: kV with a lowercase k, MV with a capital M. A lowercase mV is a millivolt and is a billion times smaller than an MV. Software that ignores case can turn one into the other without warning. When a table lists voltages for a test or a line, spell out the unit in the heading, and keep one unit per column. Look at the order of magnitude of the result before using it. A 765 kV line is a number a little below one megavolt, never a number in the millions.
Safety and scope
This page restates a voltage in a different unit. It does not say whether a voltage is safe, how far a clearance must be, or whether equipment is rated for a test. High voltage is dangerous, and testing or working near it requires training, procedures and standards that no unit converter can replace. The conversion is exact for every input, so a surprising answer most often comes from a typed exponent or a reversed unit pair. Check the labels on the source before suspecting the arithmetic.