Two systems of magnetic units

Magnetic flux is written in webers in the SI system and in maxwells in the older CGS system. Modern textbooks, simulation software and lab equipment use webers and their prefixes. Magnet manufacturers, older fluxmeters and some magnetizer manuals still print values in maxwells, gauss and oersteds. A person reading both kinds of document, such as a technician checking a charger setting against a magnet datasheet, needs a reliable way to move between them. This page multiplies microwebers by 100 to give maxwells, and divides by 100 for the reverse direction. It converts the unit only, and says nothing about whether a magnet, core or sensor meets any requirement.

Where 100 comes from

The maxwell is defined as 10^-8 weber, so one weber is 100,000,000 maxwells. A microweber is 10^-6 weber, which is 10^-6 divided by 10^-8, or 100 maxwells. The formula on this page is Mx = µWb × 100. With the default of 10 µWb, the result is 1,000 Mx, and the page may show 999.9999999999999 because of binary floating-point arithmetic. That is the same as 1,000. NIST SP 811 lists the maxwell as a CGS unit and gives the relation to the weber. The reverse factor is 0.01, so 250 Mx is 2.5 µWb.

Flux, field and area

Magnetic flux through a surface equals the flux density times the area, when the field is uniform and perpendicular to the surface. In SI, tesla times square meter gives webers. In CGS, gauss times square centimeter gives maxwells, so a field of 1 gauss over 1 cm² carries 1 Mx. Take a field of 1,000 G over a 2 cm² area. That is 2,000 Mx, which equals 20 µWb. The same case in SI is 0.1 T over 2 × 10^-4 m², which is 2 × 10^-5 Wb, or 20 µWb. The agreement confirms the factor. The page does not compute flux from field and area, and it performs the unit step.

A search coil and a pickup area

Suppose a small pickup coil encloses an area of 25 mm², which is 25 × 10^-6 m², in a uniform field of 0.1 T. The flux is 2.5 × 10^-6 Wb, which is 2.5 µWb. In maxwells, that is 250 Mx. A fluxmeter manual might ask you to enter the coil area and turns in cm², and the result may appear in maxwells, so the conversion lets you check it against a calculation in SI. If the coil has 100 turns, the flux linkage is 100 times larger, 250 µWb-turns or 25,000 Mx-turns. Keep track of whether a figure is flux or flux linkage, since the units look alike.

Integrating a voltage pulse

Faraday induction ties flux to voltage: the voltage induced in a coil equals the rate of change of flux linkage. Integrating a voltage over time therefore gives flux linkage in volt-seconds, and one volt-second is one weber. A fluxmeter or an oscilloscope integration of a 2 mV pulse lasting 5 ms gives 2 × 10^-3 V × 5 × 10^-3 s = 10 µV·s, or 10 µWb-turns. That is the default value on this page, and it equals 1,000 Mx-turns. For a single-turn coil, the flux is 10 µWb. Dividing by the number of turns gives the flux through each turn. The page does the unit step, and the integration comes from the measurement.

Magnet datasheets and charger settings

Permanent magnet datasheets often give a total flux for a magnet or assembly at a stated condition, in maxwells or in milliwebers, and magnetizing equipment manuals may use CGS units. A value of 20,000 Mx is 200 µWb, or 0.2 mWb. Matching a measured flux from a fluxmeter that reads in microwebers to a magnet specified in maxwells needs this factor. The values of flux depend on the measurement setup, the coil used and the state of the magnet, so the conversion makes the units match without making the measurements comparable if the conditions differ. Check the test conditions given in the source. Two magnets quoted at 20,000 Mx and 25 µWb are not the same strength: 20,000 Mx is 200 µWb, eight times larger than 25 µWb, and the table in a catalog may mix the units from row to row.

CGS and SI companions

The maxwell belongs to a family. Flux density in CGS is the gauss, and 1 T equals 10,000 G. Field strength is the oersted in CGS and the ampere per meter in SI. Using one system consistently avoids errors, because mixing gauss with webers gives wrong answers without any warning. When a document mixes unit systems, convert everything to SI first, calculate, and convert back at the end if needed. A small table of factors, such as 1 Mx = 10^-8 Wb, 1 G = 10^-4 T and 1 Mx per cm² = 1 G, makes checking quick. For example, 1 G over 1 cm² is 10^-4 T over 10^-4 m², which is 10^-8 Wb, and that is again 1 Mx, so the three factors agree with each other. This page covers the flux step for microwebers.

Reading small flux values

Output values in maxwells are often large whole numbers, since the maxwell is a small unit. A flux of 0.35 µWb is 35 Mx, and 12.5 µWb is 1,250 Mx. In the reverse direction, 1 Mx is 0.01 µWb, and 8 Mx is 0.08 µWb. Use significant digits that match the measurement, since a fluxmeter reading with three digits does not justify more. Label each figure with its unit symbol, Wb or Mx, and use the micro sign for µWb. An unlabeled number in a magnetics report is a common cause of factor-of-100 errors, which is easy to avoid with a quick conversion check. When you transcribe a magnet or core specification into a design file, add a column that states the unit system, and convert at entry time so later formulas all work in webers.

Saturation, exposure and device instructions

The conversion changes the unit of a magnetic flux. It does not calculate flux from a field, predict saturation or assess any device. It also does not address exposure limits, medical device safety or other compliance topics, which come from the relevant standards and manufacturer instructions. The maxwell definition and its relation to the weber are given in NIST SP 811. Displayed values are rounded, and some results may show a floating-point tail in the last digits, so read 999.9999999999999 as 1,000.