MEASUREMENT & METHODS

Gauss (G): magnetic flux density unit guide

G is the supported gauss unit for magnetic flux density.

Measurement basis

One G corresponds to 0.0001 T.

Definition conventions

This group measures B. H-to-B requires permeability and material information.

Conversion method

Multiply G by 0.0001 for the reference flux density.

Reference equivalent of G

1 G = approximately 0.0001 T.

Recorded scale factors: 0.0001 for G; 1 for T.

Worked example

Known input: 10 G. Reference equivalent: 0.001 T. The return conversion gives approximately 10 G.

The reference calculation uses the gauss definition.

Common reference values

Input (G)Reference equivalent (T)
10.0001
50.0005
100.001
250.0025
500.005
1000.01

Compare one G with other units

Target unitEquivalent of 1 GDefinition guide
Teslas (T)0.0001Read definition
Milliteslas (mT)0.1Read definition
Microteslas (µT)100Read definition
Nanoteslas (nT)100000Read definition
Milligauss (mG)1000Read definition
Picoteslas (pT)100000000Read definition

A CGS unit that outlived its system

The gauss, symbol G, is the unit of magnetic flux density in the centimeter-gram-second system of units, named after the German mathematician and physicist Carl Friedrich Gauss. In SI the same quantity is measured in teslas, and the link is fixed by definition: 1 T equals 10,000 G, so 1 G equals 0.0001 T or 100 µT. NIST SP 811 lists the gauss among units outside SI that are still encountered, and the BIPM SI Brochure places it among CGS electromagnetic units. The unit remains alive because magnet suppliers, gaussmeters, physics textbooks and electromagnetic field survey instruments still print it on their displays and data sheets.

The scale from nanotesla to magnet face

Typical values span many orders of magnitude, which is why the gauss and its prefixed forms stay useful. Earth magnetic field at the surface is roughly 0.25 to 0.65 G, which is 25 to 65 µT, with the weaker values near the equator and the stronger values near the poles. A refrigerator magnet gives about 50 G at its face, or 5 mT. A neodymium magnet face can read 3,000 to 5,000 G, which is 0.3 to 0.5 T. A clinical MRI scanner at 1.5 T corresponds to 15,000 G and at 3 T to 30,000 G, which is why a small gaussmeter range of 0 to 20,000 G covers most hobby work. Superconducting research magnets reach 20 T and beyond, or 200,000 G, and the strongest steady fields produced in laboratories are several times higher. Interplanetary space sits at the other end, with fields near a few nanoteslas, or a few hundred-thousandths of a gauss.

Milligauss and household field surveys

Handheld electromagnetic field meters usually read in milligauss, where 1 G equals 1,000 mG and 1 mG equals 0.1 µT. Household readings near appliances can range from a fraction of a milligauss to tens of milligauss close to a motor or transformer. A figure of 2 mG is 0.2 µT. The reference level published by ICNIRP in 2010 for 50 Hz fields and the general public is 200 µT, which is 2,000 mG. Comparing a meter reading to a guideline therefore starts with the conversion factor of 10 mG per µT, and the guideline must be taken from the document for the right frequency, since limits depend on how fast the field alternates.

Conversion factors for this page

Every conversion on the site is a power of ten. A reading of 1 G equals 0.1 mT, 100 µT, 100,000 nT and 1,000 mG. In the other direction, 1 mT is 10 G and 1 µT is 0.01 G. A bench magnet of 4,200 G is 0.42 T. An MRI scanner at 7 T used for research equals 70,000 G. Because the factor between gauss and tesla is 10,000, you can move the decimal point four places: 0.5 G becomes 0.00005 T, written 50 µT. The converter for this unit handles tesla, millitesla, microtesla, nanotesla, gauss and milligauss, and it gives the same results as this arithmetic.

Gauss, oersted and maxwell are three quantities

The CGS system gives separate names to quantities that SI sometimes writes with similar symbols. The gauss measures flux density B. The oersted, symbol Oe, measures magnetic field strength H, and in SI that quantity uses amperes per meter. The maxwell, symbol Mx, measures magnetic flux, which SI measures in webers, where 1 Mx equals 10⁻⁸ Wb. By dimension, 1 G equals 1 Mx per square centimeter. In vacuum a field of 1 Oe pairs with a flux density of 1 G in CGS, which tempts people into treating the two as interchangeable. In a material, permeability links them, so the number of gauss need not match the number of oersted at all.

How gaussmeters report a field

Hall-effect probes sense flux density at a point and display it in G, mT or both. Many readings depend on the probe orientation, since a flat Hall element responds to the component of the field perpendicular to its face. Rotating the probe through the field and recording the largest value gives the field magnitude at that point. Magnetic fields from permanent magnets fall off rapidly, so a reading 5 mm from a face can differ by a large factor from one at 20 mm. Report the distance with the number, because a bare value of 1,200 G means little if the probe sat at an unknown spacing from the magnet.

Gauss symbol G versus grams

The unit symbol is a capital G, and the gauss takes no plural s in symbol form. Writing 600 G or 0.06 T is acceptable, but writing 600 g would read as 600 grams. Many sources write gauss for the same unit as G, and some older papers write Gs, which the SI Brochure style does not recommend. When converting from a data sheet that gives the residual flux density Br of a magnet in kG, multiply by 1,000 to get gauss: Br of 13.2 kG is 13,200 G, or 1.32 T. Keep three significant figures for such readings, since manufacturing tolerance on permanent magnet grades is typically within several percent.

Gauss and the origin of the name

Carl Friedrich Gauss worked on terrestrial magnetism in the 1830s with Wilhelm Weber, and together they organized a network of magnetic observatories and developed absolute measurements of the field in terms of length, mass and time. That work is why their names sit on the CGS and SI units: gauss for flux density, and weber for flux. Gauss also introduced the idea of expressing magnetic quantities with the same base units as mechanics, which led later to the CGS electromagnetic system. The International Electrotechnical Commission adopted the name gauss for the CGS unit of flux density in 1930, and the 1960 adoption of the tesla in SI then gave the same quantity a coherent unit.

Limits of a unit conversion

A conversion tells you how the same flux density appears in another unit. It does not tell you how strong a magnet is for lifting, since pull force depends on area, material, gap and geometry. It also does not show whether a field is safe for a pacemaker, a medical implant or a piece of equipment, which depends on frequency, exposure rules and device ratings. For that you need the manufacturer documentation and the relevant standards. The tesla remains the SI unit for formal work, but gauss keeps appearing in product literature, so converting between the two with confidence is a practical skill for anyone who reads magnet data sheets.

Precision and checking

  • Keep source flux-density precision.
  • Retain G as a unit rather than a prefix alone.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →