Two units for the same magnetic field
Magnetic flux density is measured in teslas in the SI and in gauss in the older centimeter-gram-second system. Both are still in use. Magnetometers in phones and field survey instruments report microteslas, while EMF meters sold for consumers often show milligauss, and permanent magnet specifications mix gauss and tesla. This page converts a value in gauss to microteslas. The default of 10 G gives 1,000 µT. The formula is µT = G × 100. The factor comes from the definition of the gauss as exactly 10^-4 T, which NIST SP 811 lists, and the micro prefix as 10^-6, which gives 10^-4 / 10^-6 = 100. There is no rounding in the factor, so the result is as exact as the number you enter.
Definitions of the tesla and the gauss
The tesla is the SI unit of magnetic flux density, named for Nikola Tesla. One tesla is one weber per square meter, and in base units kg·s^-2·A^-1. The gauss is named for Carl Friedrich Gauss and is the unit used in the electromagnetic cgs system, defined as one maxwell per square centimeter. Since a maxwell is 10^-8 Wb and a square centimeter 10^-4 m², one gauss equals 10^-4 T exactly. That leads to 1 T = 10,000 G. The micro prefix then makes 1 G = 100 µT. A related unit is the milligauss, 0.001 G, which equals 0.1 µT. These relations are exact, and the BIPM SI Brochure does not include the gauss among accepted units, but physics and engineering literature still uses it.
The default example, step by step
For 10 G the page multiplies by 100 and shows 1,000 µT, which is also 1 mT and 0.001 T. The result may show a trailing digit such as 1000.0000000000001, which is a floating-point artifact of binary arithmetic. A second example is 0.5 G, a typical strength for the Earth's field at the surface, which is 50 µT. A third is 1 G, which is 100 µT. A fourth is 15,000 G, which is 1.5 T, the field strength of many clinical MRI scanners, and equals 1,500,000 µT. In each case the digits stay the same and the decimal point moves two places. A quick mental check is that microteslas are a hundred times larger in number than gauss, because the microtesla is a smaller unit.
The Earth's field
The Earth's magnetic field at the surface ranges from roughly 25 to 65 µT, which is 0.25 to 0.65 G. It is weakest over South America and the South Atlantic, and strongest near the magnetic poles. In mid-latitudes of the United States, a typical total field is around 50 µT, or 0.5 G. A compass responds to the horizontal component, which is smaller, and to local fields from steel and magnets. Smartphone magnetometers report in microteslas, and a reading near 25 to 65 µT on an unobstructed device is expected. If the reading is far higher, a nearby magnet, speaker or steel object is the likely cause. The numbers are approximate, and models such as the World Magnetic Model provide the values for a location and date.
Everyday and industrial magnets
A small refrigerator magnet gives a few millitesla at its surface, which is tens of gauss, and the field falls rapidly with distance. A neodymium magnet of a size used in craft projects can reach 0.3 to 0.5 T at the pole face, which is 3,000 to 5,000 G, or 300,000 to 500,000 µT. A clinical MRI scanner runs at 1.5 or 3 T, which is 15,000 or 30,000 G. Research magnets exceed 20 T. A loudspeaker magnet gap has a field of 0.5 to 1 T. The range from the Earth's field at 50 µT to an MRI at 3,000,000 µT spans about five orders of magnitude. These are rounded typical figures that depend on the design. The page converts the number you enter and does not verify any magnet specification.
Milligauss and EMF meters
Consumer EMF meters, sold for checking appliances and wiring, often display milligauss. One milligauss is 0.1 µT, so a reading of 2 mG is 0.2 µT. Household appliances near the body can produce fields in the range of a few to a few hundred milligauss at close range, falling quickly with distance, and mains-frequency fields in typical living spaces are generally low, often below 1 µT. Exposure guidelines, such as those of the ICNIRP for low-frequency fields, state limits in microteslas, with the 2010 guideline at 200 µT for the general public at 50 Hz. This page does not assess exposure, equipment ratings or compliance. It restates a flux density in another unit, and the interpretation depends on frequency, distance, duration and the standard that applies to your situation.
Reading magnetometers and sensors
Hall-effect sensors and magnetoresistive chips on circuit boards report magnetic field in gauss or microteslas, depending on the manufacturer. A datasheet might list a sensitivity of 1.5 mV per gauss or a range of plus or minus 8 gauss, which is plus or minus 800 µT. A digital compass IC with a full-scale range of 4 G covers plus or minus 400 µT, which is wider than the Earth's field by a factor of eight, leaving headroom for hard-iron offsets from nearby parts. When you port code between sensors, a unit mismatch of 100 shows up as a compass that seems to swing too little or too much. Converting once at the data-handling boundary avoids it. The page gives the factor for a hand check of those numbers.
Reverse conversion and checks
To convert microteslas to gauss, choose microteslas in the From list and gauss in the To list. The page divides by 100. Entering 25 µT returns 0.25 G, the low end of the Earth's field. Entering 65 µT returns 0.65 G. A good check is that 1 mT should be 10 G and 1 T should be 10,000 G. Chain through teslas: 10 G is 0.001 T, which is 1,000 µT, matching the direct result. The lists also include milliteslas, nanoteslas, picoteslas and milligauss, so you can test the whole ladder. When two conversion paths disagree, the cause is usually a missed factor of 10 or 1,000 in a prefix, which the chain check will show.
Scope and cautions
This page does not calculate installation limits, equipment ratings, protection, material response or compliance. It converts one magnetic flux density value from gauss to microteslas. It does not tell you whether a field is safe, whether a medical device is affected, or whether a sensor is within range. People with implanted medical devices should follow the guidance of the manufacturer and their physician about magnetic fields. For definitions, see the BIPM SI Brochure and NIST SP 811. Keep the original gauss value in your records beside the converted result.
A worked example: checking a compass sensor
A magnetometer chip is specified with a measurement range of plus or minus 4.9 G and the phone app displays in microteslas. The range converts to plus or minus 490 µT. The Earth's field near 0.5 G is 50 µT, so the sensor has headroom of about ten times the signal. Suppose the app reads 1,300 µT near a speaker. That is 13 G, which is above the sensor range and would saturate it, so the reading cannot be trusted. Divide by 100 to see the gauss value quickly. A reading of 38 µT is 0.38 G and falls within the Earth's normal range. The sensor specifications here are illustrative, and a real device has its own range and offsets listed in the datasheet. Always convert the range and the reading to the same unit before comparing them.
Magnetic fields at a distance
Field strength falls off quickly from a source. For a small bar magnet, the on-axis field drops roughly with the cube of the distance, so doubling the distance cuts the field to about one eighth. A magnet that gives 500 G (50,000 µT) at 1 cm would give about 62.5 G (6,250 µT) at 2 cm and 7.8 G (780 µT) at 4 cm, under the ideal dipole approximation that holds at distances larger than the magnet size. By 20 cm the field would be near 0.06 G, or 6 µT, below the Earth's background of 25 to 65 µT. This is why a magnet that sticks hard to a fridge has little effect on a compass a meter away. The numbers are illustrative values from the dipole model, and real magnets differ. The page converts a single field value and not a field profile.
Writing the result in a report
When you convert a field reading for a report, state both values and the instrument. For example, a reading of 0.52 G (52 µT) taken with a calibrated three-axis magnetometer at a stated location and date. Keep the number of significant figures equal to that of the reading, so 0.52 G becomes 52 µT and not 52.000 µT. Note whether the value is the total field magnitude or one axis, because a single component can be much smaller than the total. For a three-axis reading, the magnitude is the square root of the sum of the squares of the components, so components of 20, 5 and 45 µT give 49.5 µT. Writing down the unit of each component, and converting all of them before combining, avoids mixing gauss and microteslas in the same square root.