MEASUREMENT & METHODS

Microteslas (µT): magnetic flux density unit guide

µT is the micro-prefixed flux-density entry.

Measurement basis

Its reference factor is 10^-6 T.

Definition conventions

This group measures B. H-to-B requires permeability and material information.

Conversion method

Multiply µT by 10^-6 for teslas.

Reference equivalent of µT

1 µT = approximately 0.000001 T.

Recorded scale factors: 0.000001 for µT; 1 for T.

Worked example

Known input: 10 µT. Reference equivalent: 0.00001 T. The return conversion gives approximately 10 µT.

The small reference result preserves flux density.

Common reference values

Input (µT)Reference equivalent (T)
10.000001
50.000005
100.00001
250.000025
500.00005
1000.0001

Compare one µT with other units

Target unitEquivalent of 1 µTDefinition guide
Teslas (T)0.000001Read definition
Milliteslas (mT)0.001Read definition
Nanoteslas (nT)1000Read definition
Gauss (G)0.01Read definition
Milligauss (mG)10Read definition
Picoteslas (pT)1000000Read definition

The microtesla in the SI

A microtesla, µT, is one millionth of a tesla, 10^-6 T. The tesla is the SI unit of magnetic flux density, defined as one weber per square meter, and in base units it is kg/(A·s²). It is named after the engineer Nikola Tesla, and the General Conference on Weights and Measures adopted the name in 1960. The micro prefix, symbol µ, stands for 10^-6. In neighboring units, 1 µT equals 1,000 nT, 0.001 mT, 0.01 gauss and 10 milligauss. The unit is the practical scale for weak fields, including the geomagnetic field, ambient fields in buildings and the readings of consumer magnetometers. Many people meet the microtesla first in the compass or sensor display of a smartphone, where the field components are reported in µT. The reference scale is the tesla itself, so converting a µT value to teslas multiplies by 10^-6.

The micro sign and its look-alikes

The prefix symbol is the Greek letter mu, µ, and two characters look nearly identical in text. U+00B5 is the micro sign and U+03BC is the Greek small letter mu. Both display as µ, but software that searches or parses text may treat them as different characters, and a data file that mixes them can break a unit lookup. Plain-text sources often substitute a lowercase u, writing uT, which is unambiguous to humans in context but is not the SI symbol. Be careful with mT and µT in handwritten notes, where a micro can be mistaken for an m, a mistake that changes the value by a factor of 1,000. Keep the micro prefix, and in a table it is worth writing the unit once in the header with the symbol spelled correctly, then leaving the cells as plain numbers.

Reading the micro prefix

One microtesla equals 0.000001 tesla, so a reading of 25 µT is 0.000025 T. Because the tesla is the larger unit, the number of teslas is always much smaller than the number of microteslas for the same field. A reading of 48 µT equals 4.8 × 10^-5 T, 0.48 G and 480 mG. A reading of 0.8 µT equals 800 nT or 8 mG. Larger values stay in the same pattern: 3,500 µT is 3.5 mT or 0.0035 T. The conversion is a shift of six decimal places toward the front for teslas and three places for millitesla. Counting groups of three zeros helps avoid mistakes. A result of 25,000 T from a 25 µT reading would be a field comparable to nothing on Earth outside special laboratories, which is a quick sign that the factor was applied in the wrong direction.

Typical field magnitudes in microteslas

The geomagnetic field at the Earth's surface ranges from roughly 25 µT near the equator in parts of South America and the South Atlantic to over 60 µT near the magnetic poles, with mid-latitude values near 40 to 55 µT. The World Magnetic Model published by NOAA's National Centers for Environmental Information and the British Geological Survey gives values for a chosen place and date. A small refrigerator magnet produces a field of a few millitesla at its surface, which is a few thousand µT, and a clinical MRI scanner at 1.5 T has a field of 1,500,000 µT. These anchors place a reading on a scale. A phone that reports 45 µT in a quiet outdoor spot is in the ordinary range, while a reading of 450 µT suggests a nearby magnet or steel object that distorts the measurement.

Vector components and magnitude

A three-axis magnetometer returns the field components along the device axes, and the total magnitude is the square root of the sum of the squares. For readings of 20 µT, -5 µT and 42 µT, the magnitude is √(400 + 25 + 1,764) = √2,189 = 46.8 µT. In teslas that is 4.68 × 10^-5 T. The components depend on the orientation of the device, but the magnitude should stay nearly constant when the device is rotated in a uniform field. If the magnitude changes much during rotation, the sensor needs calibration or there is a magnetic disturbance nearby. A conversion from µT to T applies to each component and to the magnitude in the same way. Keep the sign of the components, because it tells direction, and report which axes and reference frame the numbers use.

Sensors, calibration and disturbances

Consumer magnetometers are typically Hall-effect or magnetoresistive chips that report the field in µT. Their readings contain offsets from permanent magnets and magnetized parts in the device, called hard-iron effects, and scale distortions from soft magnetic materials, called soft-iron effects. Phone operating systems run calibration routines, often asking the user to move the phone in a figure-eight, to estimate these errors. Nearby loudspeakers, magnetic cases, vehicles, steel reinforcement and electrical currents can shift the reading by tens of microteslas. A unit conversion does not establish how a magnetic reading was taken, so note the instrument, calibration status, orientation and surroundings along with the value. A reading taken indoors next to a desk with a steel frame and one taken in an open field may differ by more than the geomagnetic variation across a continent.

Microtesla and the tesla in practice

The microtesla is a smaller scale than the lab units. Superconducting magnets and electromagnets are specified in tesla, small permanent magnets in millitesla, and weak environmental fields in microtesla or nanotesla. Geophysical surveys use nanotesla, where 1 nT is 0.001 µT, and magnetically sensitive experiments such as magnetoencephalography deal with fields measured in femtotesla, a billion times smaller than a microtesla. A conversion from µT to T is useful when the value feeds an SI equation, such as the force on a moving charge, F = qvB. A proton moving at 10^5 m/s perpendicular to a 50 µT field experiences a force of 1.602 × 10^-19 × 10^5 × 5 × 10^-5 = 8.0 × 10^-19 N. The tiny force illustrates the scale. Plug the field in as 5 × 10^-5 T and not as 50.

Relation to field strength in A/m

In air or vacuum, flux density in tesla equals μ0 times field strength in A/m, with μ0 ≈ 1.25663706 × 10^-6 N/A². So 1 µT corresponds to 1 × 10^-6 / 1.25664 × 10^-6, about 0.7958 A/m, and 50 µT corresponds to 39.8 A/m. This relation holds only where the surroundings have a relative permeability close to one. Within a magnetic material, the same flux density corresponds to a different field strength. Teslas and microteslas describe magnetic flux density and are not a direct substitute for magnetic field strength, magnetic flux or a device's operating specification. A magnetic flux in webers is the flux density times an area, so 50 µT through 0.01 m² is 5 × 10^-7 Wb. The three quantities need different names even when their numbers look related.

The reverse check

Multiplying the tesla result by 1,000,000 recovers the original microtesla value, which is a quick test that the conversion is correct. For the 25 µT example, 0.000025 T × 1,000,000 = 25 µT. A second check uses the gauss: 25 µT is 0.25 G, and 0.25 × 10^-4 T gives 0.000025 T again. Two paths agreeing confirms both the factor and the placement of the decimal. Beyond arithmetic, keep the measurement location, instrument, date and uncertainty with the number. The geomagnetic field changes slowly over years, with daily variations of tens of nanotesla and larger disturbances during geomagnetic storms, so a reading without a date and place has limited meaning. Store those details alongside the converted value, not only the number.

Horizontal and vertical components for compass use

A compass responds to the horizontal part of the geomagnetic field, which is smaller than the total except at the magnetic equator. The inclination I is the angle between the field and the horizontal plane. The horizontal component is F cos I and the vertical component is F sin I, where F is the total flux density. At a place with a total field of 50 µT and an inclination of 60 degrees, the horizontal component is 25 µT and the vertical component is 43.3 µT. Near the magnetic poles the horizontal part becomes very small, which is why compasses behave poorly at high latitudes. Declination, the angle between magnetic and geographic north, is given separately and is reported in degrees. Phone compass apps combine these quantities with the reading in µT, so the unit conversion on this page applies equally to F, to the horizontal part and to the vertical part, while the angles keep their own units.

Precision and notation

Write the symbol as µT with a space after the number, as in 25 µT. The case matters: a capital T is required, since lowercase t is the tonne. Keep the micro sign consistent in files and use the SI form instead of uT where the system supports it. A converted value should keep the number of significant figures of the reading: 25 µT is 2.5 × 10^-5 T, and 25.0 µT would be 2.50 × 10^-5 T. Consumer sensors usually resolve to a fraction of a microtesla, with accuracy of a few microteslas after calibration, so reporting five digits is false precision. Retain the resolution of the source and round only at the end. Apps that show nanotesla follow the same pattern: 45,000 nT is 45 µT, 0.045 mT, 0.00045 G and 450 mG. A value of 45 µT is also 0.45 G, which is the figure older geomagnetic maps print for mid-latitude locations. When combining values from different sensors, state each unit and convert to a common unit before adding or averaging.

Precision and checking

  • Keep measured flux-density resolution.
  • Retain the micro prefix.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →