MEASUREMENT & METHODS

Picoteslas (pT): magnetic flux density unit guide

pT uses the pico prefix for magnetic flux density.

Measurement basis

One pT corresponds to 10^-12 T.

Definition conventions

This group measures B. H-to-B requires permeability and material information.

Conversion method

Multiply pT by 10^-12 for the reference.

Reference equivalent of pT

1 pT = approximately 1e-12 T.

Recorded scale factors: 1e-12 for pT; 1 for T.

Worked example

Known input: 10 pT. Reference equivalent: 1e-11 T. The return conversion gives approximately 10 pT.

The calculation preserves flux density.

Common reference values

Input (pT)Reference equivalent (T)
11e-12
55e-12
101e-11
252.5e-11
505e-11
1001e-10

Compare one pT with other units

Target unitEquivalent of 1 pTDefinition guide
Teslas (T)1e-12Read definition
Milliteslas (mT)1e-9Read definition
Microteslas (µT)0.000001Read definition
Nanoteslas (nT)0.001Read definition
Gauss (G)1e-8Read definition
Milligauss (mG)0.00001Read definition

Fields a million times weaker than the Earth

The picotesla, symbol pT, is 10⁻¹² tesla. The tesla is the SI unit of magnetic flux density, equal to one weber per square meter, or kg·s⁻²·A⁻¹. Earth magnetic field at the surface is roughly 25 to 65 µT, so about 50 µT or 5 × 10⁷ pT is a typical value. The unit is therefore used for fields tens of millions of times smaller, such as the signals produced by the human heart and brain or the weak variations measured in geophysics. A picotesla is also 10⁻⁸ gauss, since one gauss equals 10⁻⁴ T. Instruments for this range, such as SQUIDs and optically pumped magnetometers, must be shielded from the much larger fields around them.

Heart, brain and other biomagnetic signals

Magnetocardiography records fields from the heart of the order of 50 pT at the chest surface, which is about a millionth of the Earth field. The relation 50 pT divided by 50 µT is 10⁻⁶. Magnetoencephalography measures brain activity, with spontaneous and evoked fields between about 10 and 1,000 fT, so a few tenths of a picotesla in the strongest rhythms such as alpha. These values are rounded and vary with the subject and sensor distance. MEG systems sit in magnetically shielded rooms and use arrays of SQUID sensors cooled with liquid helium, with newer systems using optically pumped sensors that work at room temperature. Because the signals are tiny, picotesla and femtotesla are the natural units.

Geophysics and natural magnetic fluctuations

Magnetotelluric surveys use natural variations of the geomagnetic field to infer the electrical structure of the ground. The signals cover a wide range, from picoteslas in the quiet upper frequency bands to nanoteslas and larger during magnetic storms. Schumann resonances, caused by lightning in the cavity between the ground and the ionosphere near 7.8 Hz and its harmonics, produce magnetic fields in the picotesla range. Induction coil sensors with many turns detect these signals, and the voltage induced is proportional to the rate of change of flux. The unit lets a survey report both the weak background and the stronger disturbances in one scale, and it avoids exponents. The signals are weakest at the highest frequencies, so surveys average over long recording times, often hours, to bring a pT-level spectral line above the instrument noise.

Relating pT to gauss and milligauss

The Computandum magnetic flux density converters list these steps. Gauss to Picoteslas multiplies by 10⁸, and Milligauss to Picoteslas by 10⁵. Going down, Picoteslas to Gauss multiplies by 10⁻⁸ and Picoteslas to Milligauss by 10⁻⁵. Teslas to Picoteslas multiplies by 10¹², Milliteslas by 10⁹, Microteslas by 10⁶ and Nanoteslas by 1,000. A field of 0.5 G, a typical value for Earth, equals 50 µT or 5 × 10⁷ pT. One milligauss is 100 nT, and 1 pT is 0.00001 mG. A reading of 1,000 pT is 1 nT and 0.01 mG. The gauss is a unit of the CGS system and is not part of the SI, although it is still common in older instruments.

Flux density, flux and field strength

Magnetic flux density B should not be confused with magnetic field strength H, whose SI unit is ampere per meter. In vacuum B = µ0 × H, and the vacuum permeability is about 1.25663706212 × 10⁻⁶ N/A². Since the 2019 SI revision, that value is a measured quantity close to 4π × 10⁻⁷ and is no longer exact. A flux density of 1 pT in air corresponds to an H of about 0.796 µA/m. Magnetic flux, in webers, is the density multiplied by area, so 1 pT through 1 m² is 1 pWb. Because B, H and flux are related through different constants and areas, a figure in picoteslas cannot be turned into amperes per meter or webers without that extra context.

Noise and sensor sensitivity

Magnetometer specifications are given as noise density in pT per root hertz or fT per root hertz. A fluxgate sensor commonly has a noise floor of several pT per root hertz at 1 Hz, while SQUIDs and optically pumped sensors reach below 1 fT per root hertz at suitable frequencies. A sensor with 10 pT/√Hz noise observed in a 100 Hz bandwidth has about 100 pT of rms noise, which would hide a heart signal of 50 pT. A resolution of picotesla therefore requires both a quiet sensor and narrow bandwidth, and a sensor rated 1 pT/√Hz needs about 100 s of averaging to resolve 0.1 pT. Manufacturers state the frequency range and the noise at specific frequencies, since the 1/f noise rises at low frequency and can make a figure look better than it is.

Everyday sources in picoteslas

Ordinary objects produce far larger fields than the body does. A refrigerator magnet at the surface gives roughly 5 mT, which is 5 × 10⁹ pT. A power line at 50 or 60 Hz creates microtesla-level fields under it, and an electric appliance gives a few microteslas close by. Moving a steel object near a magnetometer shifts the reading by nanoteslas, which is thousands of picoteslas. That is why biomagnetic recordings need shielding and why the operator removes metal, including belt buckles and zippers. A value of a few pT is therefore a measurement of an environment that has been controlled with considerable effort, and field maps of a room are the first step before any recording. Shielded rooms made of mu-metal and aluminum reduce the Earth field and urban noise by a factor of many thousands, and active coils then cancel what remains.

Symbol, case and typical slips

The symbol pT is written with lowercase p and capital T, and the T comes from Nikola Tesla. Using PT is wrong, and mT means millitesla, a unit one billion times larger. A reading of 5 mT and a reading of 5 pT differ by the factor of 10⁹, so the case of the prefix needs to be checked on any equipment screen. The unit name teslas takes a lowercase t in running text. Gauss carries the symbol G, and in older papers gamma is a name for the nanotesla, with 1 γ = 1 nT, which is 1,000 pT. Check the original unit before applying a factor, and keep the original and the converted value together in the record. A field of 47,000 nT, a common mid-latitude value, is 47 µT or 4.7 × 10⁷ pT, and a scientist who drops three zeros has changed the field to that of a kitchen magnet.

Precision and checking

  • Keep source measurement resolution.
  • Retain the pico prefix.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →