Sensitive magnetometers and gauss-calibrated gear
Research magnetometers, shielded-room instruments and brain-signal sensors report field strength in picoteslas or even femtoteslas. Compasses, gaussmeters, speaker magnets and older reference tables still use gauss. A technician who sets up a magnetically quiet test area, or a student reading a paper from a different decade, ends up with two units in the same notebook. This page multiplies a picotesla value by 10^-8 and returns gauss. The result is usually a very small decimal, so it is shown in scientific notation. That keeps the exponent visible and prevents a miscounted zero from turning a faint field into one that is ten times stronger.
Gauss as a CGS unit and its tesla value
The gauss is the magnetic flux density unit of the centimeter-gram-second system, and one gauss equals 10^-4 T, which is 100 µT. NIST SP 811 lists it among the units outside the SI that remain in use. The tesla is the SI unit, defined as one weber per square meter. Because pico is 10^-12, one gauss equals 10^8 pT, and the formula is G = pT × 1e-8. By hand, move the decimal point eight places to the left. A field of 50,000,000 pT is 0.5 G, and one of 20,000 pT is 2 × 10^-4 G. The factor is exact, since both the prefix and the gauss are defined. One gauss is also 0.1 mT, so 100 G is 10 mT, a handy cross-check against magnet datasheets.
Ten picoteslas as a fraction of a gauss
The page begins with 10 pT, which equals 1 × 10^-7 G. That is a ten-millionth of a gauss and about a five-millionth of the field you feel from the planet on a compass. A magnetometer that resolves 10 pT is therefore sensitive to changes far smaller than the background field in any room. The comparison explains why shielding and careful placement matter in quiet measurements: a nearby steel desk or a moving vehicle can create changes of many nanoteslas, which is thousands of picoteslas. If the converted number is larger than your input, the units were typed in the wrong order, because the gauss is the larger unit.
The planetary field in both units
The magnetic field at the surface of the planet is roughly 25 to 65 µT depending on location, which is 0.25 to 0.65 G. A mid-range value of 0.5 G equals 50 µT and 5 × 10^7 pT. Navigation apps, hiking compasses and smartphone sensors work with fields of this size, and a site survey for a sensitive instrument starts by measuring it. Expressing the same field in picoteslas shows how many steps of resolution a sensor needs to see small disturbances on top of it. A change of 10 pT on a 50 µT background is one part in five million, which only the best instruments resolve. Quiet-room work therefore subtracts the planetary background or measures inside a shield.
Magnets on the workbench in gauss
Magnet sellers and hobby builders often quote surface fields in gauss. A refrigerator magnet might read a few millitesla, and 5 mT is 50 G. A small neodymium magnet can reach a few thousand gauss at its surface, which is a few tenths of a tesla. A clinical MRI scanner at 1.5 T has a field of 15,000 G. Putting these figures in picoteslas produces huge numbers, 5 × 10^9 pT for the refrigerator magnet, so scientific notation is the sensible choice. The field falls off quickly with distance, so a surface reading does not describe the field a few centimeters away. A gaussmeter measures at the probe tip, so the reading also depends on where the sensing element sits and which way it faces.
Biomagnetic signals and quiet rooms
The magnetic fields of the human heart and brain are tiny. Heart signals are on the order of tens of picoteslas and brain signals are smaller still, down to the femtotesla range. A 60 pT heart signal is 6 × 10^-7 G. Measuring such fields takes superconducting or optically pumped sensors in a magnetically shielded room, and a research paper may mix picoteslas for the signal with gauss or microteslas for the residual field in the room. Writing the signal in gauss highlights how small it is next to even a refrigerator magnet. The page only converts the numbers and leaves the choice of sensor and shielding to the experiment.
Gauss, oersted and the question of what is measured
Gauss measures magnetic flux density, the quantity B, which a Hall sensor or fluxgate reports. The oersted is a unit of the field strength H, and the two share a numerical value in vacuum under the CGS convention, which tempts people to swap them. In a material they differ. This converter handles flux density between picoteslas and gauss only. If a source lists oersted, A/m or a flux in maxwells or webers, work out the correct quantity before you use this page, otherwise you may convert the right number with the wrong meaning. Keep the unit symbol in the same cell as the value in any table you share.
Going from gauss back to picoteslas
To convert the other way, choose gauss as the source and picoteslas as the target. One gauss is 100,000,000 pT, and a reading of 0.5 G is 50,000,000 pT. A weak field of 0.002 G is 200,000 pT, or 0.2 µT. Older papers on magnetic cleanliness for spacecraft parts and electronics testing give limits in gauss, and a modern sensor datasheet gives noise in picoteslas, so a comparison needs the reverse step as often as the forward one. As a check on the factor, any gauss value must produce a result whose first digits match the gauss value and whose exponent is larger by eight. For example, 3 G returns 3 × 10^8 pT.
Safety and exposure questions stay outside
The result restates a flux density in another unit. It does not tell you whether a sensor is suitable, how far a shield must reduce a field, or whether a magnetic field is safe for a person or a device with an implant. Exposure guidance depends on frequency and duration and comes from the relevant standards bodies, and medical device manufacturers publish their own limits. The converter also cannot see whether a reading is a peak or an rms value, which matters for alternating fields. Use it to keep numbers consistent across sources and confirm the context of each number before you compare them.