Two systems for one field
Magnetic flux density is measured in tesla in the International System of Units and in gauss in the older centimeter-gram-second system. Both remain in daily use. Magnet makers, hobbyists and many US instrument manufacturers still quote gauss, while physics papers, standards and sensor datasheets favor tesla and its prefixed forms. The picotesla sits at the weak end of that range, used where fields are far smaller than anything a refrigerator magnet produces. This converter takes a flux density in gauss and returns picoteslas, which helps when a source in one system has to be compared with a specification in the other. Because both units describe the same quantity, the conversion is a pure scale factor, with no physics hidden in it beyond the definitions of the units and the SI prefix.
The factor of 10^8
The tesla is the SI unit of magnetic flux density, named for Nikola Tesla, and the gauss is named for Carl Friedrich Gauss. One tesla equals exactly 10,000 gauss, so one gauss is 0.0001 tesla, which is 100 microteslas. The prefix pico stands for 10 to the minus twelfth, so one tesla holds 10^12 picoteslas. Dividing 10^12 by 10^4 gives 10^8, which is 100,000,000 picoteslas per gauss. The default of 10 G gives 1,000,000,000 pT, which is also 1 millitesla. A field of 1 G is 100,000,000 pT, 0.1 mT or 100 µT. NIST SP 811 and the SI Brochure give the tesla and the prefixes, and the page relies on those definitions. The factor is exact, so the only uncertainty is in the field value you enter.
The magnetic field of the Earth
The most familiar weak field is the one under your feet. The geomagnetic field at the surface ranges from about 25 to 65 microteslas depending on location, which is roughly 0.25 to 0.65 gauss. A middle value of 0.5 G equals 50 µT and 50 million picoteslas, or 5 times 10 to the seventh. The field is strongest near the magnetic poles and weakest over parts of South America and the South Atlantic. Compass makers, drone designers and navigation engineers all deal with this field, and magnetometers in phones measure it to give a heading. Writing the Earth field in picoteslas looks odd because the numbers are large, which tells you picoteslas are meant for fields much smaller than the planetary one. The values here are approximate ranges, and local readings depend on geology and nearby steel.
What picotesla-scale fields are
Picoteslas appear when the quantity of interest is a tiny disturbance rather than a bulk field. The magnetic signals produced by the electrical activity of the heart are commonly described as tens of picoteslas at the chest surface, and the fields from brain activity are smaller still, in the femtotesla range, a thousand times below the picotesla. Geomagnetic micropulsations, which are slow oscillations driven by the solar wind, span nanoteslas down to picoteslas at times. Detecting such signals needs very sensitive devices, such as superconducting quantum interference devices or optically pumped magnetometers, and shielding from the much larger Earth field. A gauss figure of 0.5 would be useless as a starting point, but the unit conversion helps when an older paper reports a sensitivity in gauss and a modern instrument lists its noise floor in picoteslas.
Milligauss meters and household fields
Magnetic field meters used to survey electrical installations commonly read in milligauss. A milligauss is one thousandth of a gauss, which is 0.1 microtesla and 100,000 picoteslas. A reading of 3 mG therefore equals 0.3 µT, or 300,000 pT. Such meters respond to the alternating fields of power lines and appliances at 50 or 60 Hz, and the numbers depend strongly on distance from the source, since fields from a single wire fall off rapidly. The converter lists milligauss in its menu, so you can enter a meter reading directly. This page converts units. It does not tell you whether a reading is acceptable, and the limits for exposure come from standards and guidelines that specify frequency, measurement method and averaging, which should be read from the source.
A phone magnetometer and the 0.1 µT scale
The magnetometer in a smartphone reports field strength in microteslas, and its resolution is on the order of a tenth of a microtesla or finer, depending on the model. A step of 0.1 µT corresponds to 0.001 G, or 100,000 pT. The reading changes as you bring a steel object or a speaker magnet near the phone, which is why compass apps ask you to move the phone in a figure eight to calibrate. If you are comparing a phone reading with a gaussmeter that reports gauss, multiplying microteslas by 0.01 gives gauss. For instance, 48 µT is 0.48 G. The page covers the step from gauss to picoteslas directly, and microteslas appear in the menu so you can reach them in one conversion. Phone sensors are not calibrated instruments, so treat the readings as indicative only.
Strong fields: magnets and MRI
At the other end of the range, gauss and tesla give huge numbers in picoteslas. A clinical MRI scanner with a 1.5 T main field has a flux density of 15,000 G. A 3 T scanner reaches 30,000 G. Neodymium magnets in the commercial grades have remanence figures that magnet suppliers quote around 12,000 to 14,000 G, which equals 1.2 to 1.4 T. A 1.5 T field expressed in picoteslas is 1.5 times 10 to the twelfth, a number that shows why nobody uses the unit for such work. The converter handles both extremes, though the sensible unit changes. Use teslas and millitesla for strong magnets, gauss for the older catalogs, and nanoteslas or picoteslas for the faintest signals. Safety around strong fields, such as implanted device warnings, follows the manufacturer and the facility rules.
Why the gauss survives
The gauss persists for historical and practical reasons. In the CGS system, the magnetic field in vacuum has the same numerical value in gauss as the field strength H has in oersteds, which made calculations simple for earlier generations of physicists. Magnet suppliers in the United States still publish surface fields and remanence in gauss or kilogauss, and some handheld gaussmeters read in gauss by default. The SI adopted the tesla as the unit of flux density in 1960. Most standards now use it, but the gauss remains common enough that anyone who reads catalogs or old literature will meet it. A useful habit is to write both units when you report a value, such as 50 µT (0.5 G), so that readers in either tradition can check it. The converter exists to make that dual reporting accurate.
Flux density is not field strength
Magnetic flux density B and magnetic field strength H are different quantities. B is measured in tesla or gauss, and H in amperes per meter or oersteds. In vacuum, B equals the permeability of free space times H, so 1 oersted corresponds to 1 gauss in CGS units and to about 79.58 A/m when expressed as H in SI. In materials, the relation depends on the permeability, and inside a magnet B and H can differ greatly. This page converts B only, from gauss to picoteslas. It does not convert between B and H, and it does not account for the material in which a field is measured. If your instrument reports oersteds, convert with a tool meant for field strength, or check which quantity the instrument actually measures before using the result.
Reading long results
Results in picoteslas from gauss inputs are large. A field of 2.5 G becomes 250,000,000 pT, which is 2.5 times 10 to the eighth, and 1 G becomes 100,000,000 pT. Group digits in threes to read them: 250 million. For reports, scientific notation or a larger prefix is easier on the reader, so 250,000,000 pT is better written as 250 µT or 0.25 mT. Choose the prefix that gives a number between 1 and 1,000. Do not report more digits than the instrument supports. A handheld gaussmeter might have a resolution of 0.1 G and an accuracy of a few percent, so a reading of 2.5 G should not be quoted as 250,000,000.00 pT. The converter performs the arithmetic at full precision, but the meaning of the digits is up to the measurement.
Symbols to watch
A few symbol mix-ups can change a result by large factors. A lowercase p is pico, one trillionth. A capital P is peta, 10 to the 15th, so PT would be 10 to the 27th times larger than pT. A lowercase m is milli and a capital M is mega, so mT and MT differ by a factor of one billion. The unit symbol for tesla is a capital T, and gauss is a capital G. The page uses G and pT. Some meters label gauss as Gs, but G is the standard symbol. When a datasheet gives a field in mG, check whether it means milligauss or megagauss, though the latter is almost never seen outside pulsed-field physics. Keeping to the SI symbols avoids ambiguity.
What the converter does not do
Only the unit changes. A reading of 2.5 G becomes 250,000,000 pT, and the page has no view on whether that field is safe, whether a sensor will saturate, or how a shielding material will behave. For exposure limits, medical devices, electrical installations or equipment approval, apply the relevant standards and the manufacturer's documents, which specify measurement procedures and acceptable values. The factor is exact by definition, so the result carries only the uncertainty of the field value you enter.