Hall sensor sheets and magnet specs in millitesla
Datasheets for Hall switches, magnetic encoders and current sensors give operating ranges and sensitivities in millitesla or gauss. Magnet suppliers state surface fields in millitesla too. Sensitive laboratory instruments work in picoteslas. Anyone who wants to see how a quiet-room sensor relates to a part chosen for a product needs a single scale. This page multiplies a picotesla value by 10^-9 and returns millitesla. The nine-place shift is easy to miscount by hand, so the result is displayed in scientific notation, which keeps the exponent visible and lets a reader check the order of magnitude at a glance. Datasheets that list gauss need only one more step, because 10 G is 1 mT.
Nine decades between pico and milli
Pico is 10^-12 and milli is 10^-3, so one millitesla equals 10^9 picoteslas, a billion. The formula is mT = pT × 1e-9. A field of 5,000,000,000 pT is 5 mT, a field of 25 pT is 2.5 × 10^-8 mT, and one of 1.5 × 10^12 pT is 1,500 mT. The conversion is exact because both prefixes are defined powers of ten. The tesla is one weber per square meter, and the gauss relates to it as 10 mT for every 100 G, so 1 mT is 10 G. Moving the decimal nine places to the left gives the result, and checking one known case confirms it. The reference case is 1 mT returning 10^9 pT, which is worth remembering.
Ten picoteslas on a millitesla scale
The page starts with 10 pT, which is 1 × 10^-8 mT. A Hall switch datasheet might give an operate point of a few millitesla, so the starting field is a hundred-millionth of such a threshold. The comparison shows why a consumer sensor, with a noise floor in the microtesla range, cannot detect a field of tens of picoteslas, while research-grade devices can. If the result is larger than the value you entered, the unit order is reversed, since the millitesla is a larger unit than the picotesla and the number must shrink. Consumer magnetometer boards typically resolve fractions of a microtesla at best, which is why picotesla-level fields are invisible to them.
MRI field strengths in picoteslas
Clinical scanners are described by their static field in tesla, commonly 1.5 T or 3 T. A 1.5 T field is 1,500 mT and 1.5 × 10^12 pT, and a 3 T field is 3,000 mT and 3 × 10^12 pT. Brain and heart signals recorded by magnetic sensors are around ten to fifteen decades weaker, which is why those recordings take place in shielded rooms away from scanners. Writing both on the same scale shows the gap and the care needed near a magnet. A small steel object can be pulled toward a scanner with great force, a reminder that the number on the page belongs to a very real hazard.
Refrigerator magnets and hobby magnets
A thin flexible magnet of the kind used on a refrigerator door has a surface field of a few millitesla. A field of 5 mT is 5 × 10^9 pT and 50 G. Small neodymium magnets in craft and tool kits can have surface fields of a few hundred millitesla, and the value drops quickly with distance. A datasheet may list the surface field, the remanence or the pull force, which are different quantities, so check which one the number represents. This page only converts a flux density between prefixes. It does not infer pull force, which depends on geometry and the steel it grips. Two magnets with the same surface field can pull very differently if one is thicker or larger in area.
Hall switch thresholds and hysteresis
A Hall effect switch turns on when the field at the sensor passes an operate point and turns off at a lower release point. Datasheets list these in millitesla or gauss, for example an operate point near 5 mT, which equals 50 G. The difference between them is the hysteresis, which prevents chatter. When comparing two parts, put the thresholds in one unit. If a part lists 4.5 mT operate and 3.5 mT release, the hysteresis is 1 mT, or 10 G. Converting to picoteslas is rarely needed for these parts, but it helps when comparing their noise floors with a research sensor. A latch-type part behaves differently again, since it holds its state until a field of the opposite polarity arrives.
Planetary and household fields in millitesla
A field of 50 µT, a typical order for the planetary field, equals 0.05 mT and 5 × 10^7 pT. Household electrical wiring creates alternating fields that are commonly below a microtesla at normal distances, which is below 0.001 mT. These values sit far below the thresholds of Hall switches, so a magnet or a steel object near a sensor tends to dominate. Expressing them in millitesla shows how small the planetary field is next to a magnet, and in picoteslas it shows how large it is next to a quiet-room instrument. Moving a sensor a meter closer to a steel cabinet can change the reading by more than the whole signal of interest.
From millitesla to picoteslas
Choose milliteslas as the source and picoteslas as the target to go in the other direction. A field of 1 mT is 10^9 pT, 0.05 mT is 5 × 10^7 pT, and 1,500 mT is 1.5 × 10^12 pT. The numbers grow quickly, so scientific notation is the sensible format. When you compare a datasheet noise floor in picoteslas with a sensor range in millitesla, the ratio gives the dynamic range. A part with a range of ±50 mT and a noise floor of 50 nT, which is 50,000 pT, spans a ratio of one million to one in field, or 120 dB in amplitude terms.
Where the number stops being useful
A millitesla figure says nothing about the direction of the field, the gradient across a sensor or the force on an object. It also does not tell you whether the field is safe near a pacemaker or another implanted device, a question that belongs to the device manufacturer and a medical professional. The converter changes the prefix of a flux density and returns the same factor for every input. Use a measurement at the point of interest and the documentation of the sensor, magnet or scanner to judge what a field means in practice.