Survey magnetometers and quieter sensors
Land surveys for buried iron, archaeological gradiometry and drone-mounted magnetometers report in nanoteslas. The sensors used for brain and heart signals, and the noise specifications of the best field sensors, are given in picoteslas. Someone choosing an instrument for a job, or comparing a survey anomaly with a sensor noise floor, has to read both numbers as one kind of quantity. This page multiplies a picotesla value by 0.001 and returns nanoteslas. The shift is only three places, but a tool removes the chance of moving the decimal point the wrong way when the numbers are copied between a datasheet and a field notebook.
A thousand picoteslas per nanotesla
Pico is 10^-12 and nano is 10^-9, so one nanotesla equals 1,000 picoteslas. The formula is nT = pT × 0.001, and the factor is exact because both prefixes are fixed powers of ten in the SI Brochure. A field of 5,000 pT is 5 nT, 300 pT is 0.3 nT, and 20 pT is 0.02 nT. The tesla itself is one weber per square meter. For comparison with older records, 1 nT equals 10^-5 gauss, a unit that some survey archives still use under the name gamma, where one gamma is one nanotesla. Check any converted figure against that simple ratio of one thousand.
Ten picoteslas on a survey scale
The default input of 10 pT gives 0.01 nT. A typical survey magnetometer resolves about 0.1 nT, which is 100 pT, so a change of 10 pT would be well below what it can show. The comparison is useful when deciding whether an instrument can detect a target at all. If a buried object produces a disturbance of 5 nT, it is 5,000 pT, and a sensor with a noise floor of 50 pT sees it at a hundred times its noise. If the result of the conversion is larger than the number you entered, the units were selected in the wrong order.
The planetary field and its daily swing
The field at the surface is about 25,000 to 65,000 nT, depending on location, and a value of 50,000 nT equals 50 µT and 5 × 10^7 pT. On top of that background, the field moves during the day by tens of nanoteslas, and during a geomagnetic storm by hundreds, so a survey instrument that sits still still records changes. A change of 200 nT is 200,000 pT. Surveyors record a base station alongside the roving sensor so that this slow variation can be subtracted. Writing the background and the target in one unit shows how small the signal is relative to what surrounds it. A base-station log that drifts by 20 nT over an hour has moved 20,000 pT, far more than the anomaly from a small object.
Finding buried iron and pipes
Utility locators and site investigators use magnetometers to find iron pipes, drums, old foundations and hearths. The size of the anomaly depends on the mass of iron and on its distance from the sensor, falling off quickly as the sensor moves away. A shallow steel drum may produce tens or hundreds of nanoteslas, while a small buried nail gives a fraction of one. Because the signal falls with distance, a survey walks lines at a steady height. Converting a datasheet noise floor from picoteslas to nanoteslas tells you whether a sensor can see the anomalies you expect, before you spend a day collecting data with the wrong one. Walking at a steady height matters as much as the sensor, since a change of a few tens of centimeters can alter the reading as much as a small target does.
Sensor noise and dynamic range
A sensor datasheet may give a noise floor in pT per square root of hertz and a range in nT or µT. The ratio of range to noise sets the dynamic range. A sensor with a range of ±100,000 nT and a noise floor of 10 pT covers 200,000 nT in total, a ratio of about 2 × 10^7 between the full span and the noise. Converting both to picoteslas, 2 × 10^8 pT and 10 pT, shows the ratio without any prefix arithmetic. Bandwidth matters too: noise per root hertz grows with the square root of the bandwidth you use, which the converter does not apply. A density of 1 pT per root hertz over a 100 Hz bandwidth gives about 10 pT of rms noise.
Going from nanoteslas to picoteslas
To convert in the other direction, choose nanoteslas as the source and picoteslas as the target. One nanotesla is 1,000 pT, 5 nT is 5,000 pT, and 50,000 nT is 50,000,000 pT. Survey reports list their anomalies in nT, and a sensor catalog lists noise in pT, so the reverse step is as common as the forward one. The result of 0.3 nT is 300 pT, which is a useful number to remember when estimating whether a quiet sensor can see a subtle feature. As a check, any nanotesla value must return a number a thousand times larger. The same rule holds for any survey value, so 0.05 nT is 50 pT and 12 nT is 12,000 pT.
Gradient and difference readings
Many surveys use two sensors a fixed distance apart and report the difference, which removes the slowly varying background. A reading of 2 nT between sensors 1 m apart is a gradient of 2 nT/m, which is 2,000 pT/m. The page converts a flux density, so apply it to the difference and keep the per-meter part as it is. Gradiometers are favored in noisy areas because the background largely cancels. Always state whether a number is a total field, a gradient or a change from a baseline, since all three appear in nT and mean very different things. Converting a gradient from nT/m to pT/m uses the same factor of one thousand.
Decisions the converted figure cannot make
The converted figure says nothing about the target of a survey, the quality of a sensor or the safety of a field. It does not subtract the planetary background, correct for sensor orientation or filter out noise from vehicles and power lines. Those steps belong to the survey method and the instrument manual. The converter changes the prefix of a flux density and gives the same factor for every input, so a surprising result is nearly always a mistyped exponent or a swapped unit. Compare it with the anchor case, 1 nT giving 1,000 pT, before looking for another cause.