Biomagnetic signals and sensor noise on one axis

The magnetic fields produced by the heart and the brain are far weaker than the background field of the Earth. Heart signals are on the order of tens of picoteslas, and brain signals are weaker still, in the femtotesla to low picotesla range. Instruments that record them are described in picoteslas, while an ordinary magnetometer survey of the room is in nanoteslas. To judge how much the room interferes with a signal, you want both on one scale. This page multiplies the nanotesla value by 1,000 and returns picoteslas. It suits students of biomedical instrumentation, lab technicians and engineers who compare sensor data sheets in different prefixes.

Three decades from nano to pico

Nano means 10^-9 and pico means 10^-12, so one nanotesla equals 1,000 picoteslas. The formula is pT = nT × 1000. The factor is exact because both prefixes are powers of ten defined in the BIPM SI Brochure and NIST SP 811. By hand, move the decimal point three places to the right: 2.5 nT is 2,500 pT and 0.05 nT is 50 pT. Going in the other direction divides by 1,000, so 750 pT is 0.75 nT. The tesla itself is one weber per square meter, a large unit, and prefixes bring it to the scale of weak fields. Keep the three decades in mind and a slip is easy to spot.

Ten nanoteslas as ten thousand picoteslas

The default input of 10 nT returns 10,000 pT, a whole number because the target unit is smaller. At the other end, a heart-scale signal of 50 pT is 0.05 nT, a thousandth of the default. Comparing the two shows that a disturbance of 10 nT in a room is two hundred times stronger than a signal of 50 pT, and that is why such recordings need shielding and careful design. A drift of 0.2 nT during a recording is 200 pT, four times that signal. The page performs the multiplication and does not know your signal, your shielding or your filters. It gives you the common unit in which to write down both the disturbance and the signal.

Noise density is a different unit

Sensor data sheets quote a noise floor in picoteslas per root hertz, which describes how the noise scales with bandwidth. That is not the same as a field in picoteslas and cannot be compared directly with a reading. A sensor with a noise density of 20 pT/√Hz measured over a 1 Hz bandwidth has noise of about 20 pT, and over 100 Hz about 200 pT, which is 0.2 nT. The page converts a flux density and does not handle noise density. When you read a specification, note whether the unit includes the per-root-hertz term, and do the bandwidth calculation yourself before converting the final number.

Shielded rooms and the background field

The field of the Earth, roughly 25,000 to 65,000 nT, is 25 to 65 million picoteslas, which is billions of times stronger than a brain signal. Recording such signals involves magnetically shielded rooms made of layers of high-permeability metal, plus gradiometer coils that cancel uniform fields. A well-shielded space can reduce the static background by a large factor, and an unshielded room has fluctuations of many nanoteslas from passing vehicles and elevators. Converting a survey of 5 nT of drift to 5,000 pT shows how large the interference is next to a 50 pT target. The page does not model shielding. It gives the unit change for your notes. Interference of 0.3 nT from a passing elevator is 300 pT.

Reading a magnetometer log in picoteslas

High-resolution magnetometers may record in picoteslas to make the last digits visible, and then you need nanoteslas for a report. A reading of 4,800 pT is 4.8 nT, and a reading of 125 pT is 0.125 nT. The reverse direction matters when a log has been truncated to whole nanoteslas: 1 nT could hide up to hundreds of picoteslas of variation. Rounding to the nearest 0.1 nT hides up to 50 pT of detail, as much as the heart-scale signal above. If a sensor has a resolution of 10 pT, it can resolve 0.01 nT, and a log that stores only whole nanoteslas throws that resolution away. Choose the storage unit to match the sensor resolution, and record it in the file header.

Averaging and what extra digits can mean

Averaging many samples reduces random noise by about the square root of the number of samples, so a thousand samples lower random noise by a factor of about 32. A mean computed from a noisy sensor can therefore have more meaningful digits than a single reading, which is why picoteslas appear in reports about averaged data. The page shows up to twelve significant digits, and that is arithmetic and not measurement quality. Drift, temperature and sensor offsets limit what the final digits mean. State the averaging time and the bandwidth next to the result so that other people can judge its accuracy.

pT, nT and the lookalike symbols

The symbol pT is picotesla, and a capital T alone is tesla. A lowercase t is a metric ton, and a lowercase p alone is a prefix with no unit. Case matters in other ways as well: PT could be read as a petatesla, which does not occur in practice, and spreadsheets that force capitals can create it. A column labeled in nT that holds pT data is a one thousand fold error. In a figure, write the unit on the axis and use the same unit across panels that will be compared. When a source quotes femtoteslas, remember that one picotesla is 1,000 fT, so a further factor of 1,000 separates the neighboring prefixes. A field of 0.02 nT is 20 pT, which is 20,000 fT.

Shielded-room work and the original nanotesla column

Designing a shield, choosing a sensor, calculating a signal-to-noise ratio and judging whether a recording will be clean depend on the sensor, the environment and the analysis method. Calibration errors and sensor drift also fall outside this arithmetic. The converter keeps numbers consistent between nanoteslas and picoteslas, and the original nanotesla value should stay in the dataset beside the converted one. When the result supports a decision, such as selecting equipment, rely on the manufacturer specifications and on someone with experience in low-field measurement. A column header such as B (pT) removes any doubt about which unit a figure is in.