MEASUREMENT & METHODS

Nanoteslas (nT): magnetic flux density unit guide

nT expresses magnetic flux density in nanoteslas.

Measurement basis

One nT corresponds to 10^-9 T.

Definition conventions

This group measures B. H-to-B requires permeability and material information.

Conversion method

Multiply nT by 10^-9 and keep the result until final display.

Reference equivalent of nT

1 nT = approximately 1e-9 T.

Recorded scale factors: 0.000000001 for nT; 1 for T.

Worked example

Known input: 10 nT. Reference equivalent: 1e-8 T. The return conversion gives approximately 10 nT.

The example retains the source flux-density quantity.

Common reference values

Input (nT)Reference equivalent (T)
11e-9
55e-9
101e-8
252.5e-8
505e-8
1001e-7

Compare one nT with other units

Target unitEquivalent of 1 nTDefinition guide
Teslas (T)1e-9Read definition
Milliteslas (mT)0.000001Read definition
Microteslas (µT)0.001Read definition
Gauss (G)0.00001Read definition
Milligauss (mG)0.01Read definition
Picoteslas (pT)1000Read definition

What one nanotesla is

The tesla is the SI derived unit of magnetic flux density, and the nanotesla is one billionth of it, so 1 nT equals 10⁻⁹ T. The BIPM SI Brochure defines the tesla as one weber per square meter, which in base units is kg·s⁻²·A⁻¹. The name honors Nikola Tesla, and the 11th General Conference on Weights and Measures adopted it in 1960. The nano prefix is the standard SI prefix for 10⁻⁹, listed in the Brochure alongside micro (10⁻⁶) and pico (10⁻¹²). A nanotesla is a small quantity by laboratory standards. A refrigerator magnet produces millitesla-scale fields at its surface, which is a million times larger. Nanoteslas are the natural size for fields that are barely above the planetary background, which is why geophysics, space science and sensitive magnetometer work report in them.

Conversions to neighboring units

The conversions follow from the SI prefixes. One nT is 0.001 µT, 0.000001 mT and 10⁻⁹ T. Going the other way, 1 µT is 1,000 nT, 1 mT is 1,000,000 nT and 1 T is 1,000,000,000 nT. The older CGS unit is the gauss, defined so that 1 G equals 10⁻⁴ T exactly. That makes 1 G equal to 100,000 nT, and 1 nT equal to 0.00001 G, or 10 µG. A reading of 0.5 G is therefore 50,000 nT, which is also 50 µT and 0.00005 T. NIST SP 811 treats the gauss as a CGS unit outside the SI, though it still appears in older data and in some industries. Because every one of these factors is a power of ten, a conversion only moves the decimal point. The risk is miscounting places, so write the prefix with the number every time and check that the result has the order of magnitude you expect from the instrument.

The size of the geomagnetic field

The field at the surface of the Earth is a convenient yardstick. Its total intensity ranges from roughly 25,000 nT near parts of South America and the South Atlantic to roughly 65,000 nT near the magnetic poles, and mid-latitude values of 45,000 to 55,000 nT are common. In other units that is about 25 to 65 µT, or 0.25 to 0.65 G. The values change slowly with time as the field generated in the core drifts, and national geomagnetic services and the World Magnetic Model published by NOAA and the British Geological Survey give location-specific values. A reading of 48,000 nT from a magnetometer on a desk is therefore plausible, while a reading of 48 nT or 48,000,000 nT would point to a prefix error, a faulty sensor or a strong local source such as steel furniture. This habit of comparing a result with the ambient field is the quickest sanity check available for any nanotesla value.

Gamma, an old name for the same size

Older geophysics papers and survey reports give magnetic anomalies in gammas. One gamma equals exactly one nanotesla, so the two names describe the same amount, and a survey that reports a 150 γ anomaly is reporting 150 nT. The word still turns up in archived airborne survey maps and in some mineral exploration literature, which makes it worth recognizing. The Greek letter is easy to confuse with other symbols, so many modern datasets spell out nT instead. If you find a table with a gamma column, there is no scale change to apply. A typical magnetic anomaly over a buried iron body or a ship wreck can range from a few nT to hundreds of nT, depending on depth and mass. Because the unit equivalence is exact, you can copy such values into nT without any rounding concern beyond the resolution of the original survey.

Worked conversions

Three short conversions show the pattern. First, a total-field reading of 48,500 nT. Multiplying by 10⁻⁹ gives 0.0000485 T, which is the same as 48.5 µT or 0.485 G. Second, a gradiometer reports a local anomaly of 12.4 nT, and the report needs teslas. The result is 1.24 × 10⁻⁸ T. Third, a datasheet quotes sensor noise as 0.8 nT, and you want that in microteslas for comparison with a phone magnetometer. Dividing by 1,000 gives 0.0008 µT. In each case the work is a shift of the decimal point by a known number of places. Keep the number of significant digits that the instrument justified. A reading of 48,500 nT quoted to the nearest 100 nT should not become 0.04850000 T, because the extra zeros claim a precision the original never had. Scientific notation, such as 4.85 × 10⁻⁵ T, keeps the precision visible.

Space weather and the nanotesla

Space weather agencies report disturbances to the geomagnetic field in nanoteslas. The Dst index, which tracks the strength of the ring current during storms, is expressed in nT, with quiet conditions near zero and large storms driving it strongly negative, often by tens to hundreds of nT. Ground magnetometer networks record changes of the horizontal field component over minutes, and rapid variations of a few hundred nT per minute matter to power grid operators because they relate to induced currents in long conductors. In the solar wind, the interplanetary magnetic field measured by spacecraft near Earth is typically a few nT up to around ten nT in quiet conditions and rises during solar disturbances. These magnitudes are tiny next to the 50,000 nT background at the ground, yet they are large for the instruments involved. NOAA's Space Weather Prediction Center publishes such data, and the unit label on its plots is nT.

Instruments that read in nanoteslas

Several magnetometer types have resolutions on the nanotesla scale or finer. Fluxgate magnetometers are common in geophysics, satellites and compasses for ships and aircraft, and their noise is often specified in picoteslas per root hertz, which means a fraction of an nT. Proton precession magnetometers measure the total field by detecting the precession frequency of hydrogen nuclei and give absolute readings with resolutions near 0.1 nT. Optically pumped alkali-vapor magnetometers, such as cesium instruments, reach sensitivities well below 1 nT. The magnetometer chips in phones and fitness devices are far coarser, with resolution on the order of 0.1 µT (100 nT) and a calibration that drifts near metal, so datasheet values should be checked for any specific part. When you copy a value from an instrument, record its resolution. A sensor that steps in units of 100 nT cannot support a result written to the nearest 1 nT.

Flux density versus field strength

Magnetic flux density, in tesla, is a different quantity from magnetic field strength, in ampere per meter. The two are tied by the properties of the medium. In vacuum, and very nearly in air, B equals µ₀ times H, where µ₀ is about 1.25663706 × 10⁻⁶ N/A². One A/m therefore corresponds to about 1.2566 µT in air, and 1 nT corresponds to roughly 0.796 mA/m. In a magnetic material, the permeability differs and the relation changes, so a unit conversion alone cannot move between the two quantities inside iron or ferrite. Geophysical practice usually reports B, and electrical engineers working on coils often report H, which is why a nanotesla number and an A/m number from different sources should not be compared by moving a decimal point. The prefix conversion on this page only rescales B. Converting to H requires the stated medium, and the air-equivalent factor above applies only where the permeability is close to that of free space.

Very small biomagnetic and laboratory fields

Below the nanotesla sits a range that needs picotesla and femtotesla prefixes. The magnetic field produced by the beating human heart, measured with magnetocardiography, is on the order of tens of picoteslas, which is a few hundredths of an nT. Fields from brain activity detected by magnetoencephalography are smaller still, in the range of femtoteslas to a picotesla, and they are measured with SQUID or optically pumped sensors inside magnetically shielded rooms. Such rooms reduce the 50,000 nT ambient field by many orders of magnitude, since otherwise the signal would be buried. These examples explain why the nano prefix is not the end of the scale. A value written as 0.02 nT is the same as 20 pT, and writing it in the larger prefix makes the number readable. A prefix that keeps the figure between about 1 and 999 keeps the number readable.

Notation habits that prevent errors

The symbol is nT, with a lowercase n and an uppercase T. Writing NT, nt or Nt can be read as something else, and the SI Brochure reserves uppercase for symbols of units named after people. Leave a space between the number and the unit, as in 48,500 nT. Do not put a prefix on a prefix, so a thousandth of a µT is written as nT, not mµT. Keep the unit with the number in tables, since a column header that says T but holds values in nT is a common cause of thousandfold errors. When a data file records the unit in a separate metadata field, check that the field survived conversion between tools. Finally, keep the sign. Magnetic components are often reported with direction, and a negative nT value carries meaning about the axis, so the prefix conversion must preserve it. Resolution, instrument type and measurement date should travel with the number.

Reading a phone compass in nanoteslas

A phone compass app that displays field strength usually shows microteslas, and some developer tools show the raw sensor output in the same unit. A value of 47 µT is 47,000 nT, squarely inside the normal range of the Earth's field, while a reading of 300 µT, or 300,000 nT, means a magnet, a speaker or a steel structure is close to the sensor. The heading error of a compass depends on the horizontal part of the field, which is smaller than the total field away from the equator. At high latitudes much of the field points downward, so the horizontal component can fall to around 10,000 nT or less, and the compass becomes sluggish. Converting everything to one unit makes these comparisons easy to see.

Precision and checking

  • Retain measured resolution.
  • Avoid rounding a small tesla value prematurely.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →