Household field meters read in milligauss

Handheld gaussmeters sold for checking fields around appliances, wiring and transformers commonly display milligauss, while research magnetometers and phone sensors report nanoteslas or microteslas. Someone who compares a meter reading of 2.5 mG with a lab value of 250 nT wants to see that the two agree. This page multiplies the nanotesla value by 0.01 and returns milligauss. It helps homeowners who read a meter manual, students who write up a measurement, and technicians who work with equipment labeled in different systems. A milligauss figure is the same reading on a different scale. The page does not say whether a reading is typical, high or a concern, and it does not measure anything itself.

A hundred nanoteslas per milligauss

One gauss is 10^-4 T and one milligauss is 10^-7 T. A nanotesla is 10^-9 T, so one milligauss is 100 nT. The formula on the page is mG = nT × 0.01. NIST SP 811 lists the gauss and its relation to the tesla, and the BIPM SI Brochure defines the tesla as the SI unit of magnetic flux density. The factor is exact. By hand, divide by 100, or move the decimal point two places to the left. 250 nT is 2.5 mG and 1,000 nT is 10 mG. Going the other direction, 5 mG is 500 nT. It is one of the shorter conversions in the family, which makes slips in the decimal point easy to spot. A reading of 12 mG is 1,200 nT.

Ten nanoteslas as a tenth of a milligauss

The default of 10 nT returns 0.1 mG. A figure that small is below the resolution of many household meters, which often display in steps of 0.1 mG or coarser. The same default in microteslas would be 0.01 µT, a unit used by phone apps. A reading of 2 µT is 2,000 nT and 20 mG, a number that a meter might show near an appliance with a motor. The comparison shows how the three scales line up: 1 µT equals 10 mG and 1,000 nT. Keeping that triple in mind is a good way to catch a unit that was mislabeled somewhere along the way.

Alternating fields and what a meter reports

Meters for power-frequency fields usually measure an alternating field and display a root-mean-square value, sometimes with a peak or an option for single or three axes. A nanotesla value from a different instrument may be a static field, a peak value or a total of three axes. Before you compare numbers, find out what each one means. The conversion is the same, since 100 nT is 1 mG in every case, but the quantities differ in kind. A reading of 4 mG RMS is 400 nT RMS, and it does not equal a static 400 nT from a compass sensor. The page treats the numbers as given and cannot tell which kind you entered.

Fields fall off with distance

The field near a wire, a transformer or an appliance depends strongly on the distance from the source. A reading of 20 mG at the surface of a device can drop to a few milligauss within a short distance. When you note a measurement, write down the distance, the orientation of the probe and the state of the appliance. Converting 20 mG to 2,000 nT helps when you compare with a research instrument, but the numbers only match if both were taken at the same point and time. Averaging several readings over a few seconds reduces the effect of small movements. The page changes the unit and leaves the geometry of your measurement to you.

Background field and why a quiet room does not read zero

A magnetometer in a room reads the static field of the Earth as well as local disturbances, and a milligauss meter that responds only to alternating fields ignores the static part. A static reading of 50,000 nT is 500 mG, which is well above what a meter tuned to power-frequency fields shows. If you compare a research magnetometer to a household meter, check which of the two is sensitive to static fields. Otherwise you may think that one is wrong when they are measuring different things. The conversion ties the units together, and you must still decide whether the two instruments answer the same question.

Going from milligauss to nanoteslas

Choose milligauss as the source and nanoteslas as the target to multiply by 100. A meter reading of 5 mG is 500 nT and 0.8 mG is 80 nT. Many consumer meters have a resolution of 0.1 mG, which is 10 nT, so the smallest step of the meter equals the default input of this page. A published study or guideline may state a level in microteslas, and you can convert by remembering that 10 mG is 1 µT. When you document a measurement for others, give the unit the instrument displayed, and add the converted value in parentheses so that readers who use the other system can follow.

Symbols that look alike

The symbol mG is milligauss, and a capital G is gauss. A lowercase g would be gram, and mg would be milligram, which has nothing to do with magnetism. The symbol mT is millitesla, so a meter marked mT is one thousand times less sensitive than one marked mG in terms of the numbers shown, since 1 mT is 10,000 mG. A label that reads uT usually means µT, as a plain-text stand-in for the Greek letter. Spreadsheets that change case can turn mG into MG or Mg, which no longer reads as a magnetic unit. Spell out the name in a header the first time you use it and keep the symbol consistent afterward.

Household meter readings and exposure guidance

Exposure guidelines, meter calibration, the field of a wire or an appliance and the step from a field strength H to a flux density B all lie beyond the arithmetic here, which converts flux density between nanoteslas and milligauss and stops. For questions about health or compliance with a guideline, consult the published guidance of the relevant authority and a qualified professional. For measurement quality, follow the manual of your instrument and quote its stated accuracy next to every number. A converted value carries the same uncertainty as the reading it came from, expressed in the new unit.