Why magnetometer data uses both units
Geophysicists, spacecraft engineers and anyone who works with a compass-sized sensor deal with magnetic fields that are small compared with those of magnets and motors. The field of the Earth at the surface is tens of thousands of nanoteslas, and the changes that scientists and surveyors look for are a few nanoteslas or less. A smartphone magnetometer reports in microteslas, a field survey in nanoteslas. A person comparing a phone reading with a survey value, or a satellite data set with a ground station, needs the two on the same scale. This page converts a flux density from nT to µT. The tesla is the SI unit of magnetic flux density, equal to one weber per square meter. The conversion is a prefix change and does not alter the field, its direction or its source.
The factor and the default result
Nano is 10^-9 and micro is 10^-6, so one nanotesla is 0.001 µT. The formula is µT = nT × 0.001. With the default input of 10 nT the result is 0.01 µT. A value of 250 nT converts to 0.25 µT, and 48,000 nT converts to 48 µT. Going back multiplies by 1,000, so 0.5 µT is 500 nT. The factor is exact, as the SI prefixes are powers of ten and NIST Special Publication 811 lists them. Since the output is the smaller number, a conversion that increases the number has reversed the units. The converter also lists teslas, milliteslas, picoteslas, gauss and milligauss, so the same value can be expressed in the unit that a given instrument or document uses.
The size of the geomagnetic field
The magnetic field at the Earth's surface ranges from roughly 25 µT near the equator in parts of South America to about 65 µT near the magnetic poles, which is 25,000 to 65,000 nT. In mid-latitudes of Europe and North America the total field is typically around 45 to 55 µT. A reading of 48,000 nT on a magnetometer is therefore 48 µT, a perfectly ordinary value. The field has a vertical and a horizontal component whose proportions depend on the latitude, and a sensor measures whichever components it is oriented to. These are broad figures, and local anomalies caused by rocks, steel structures and electrical wiring can shift a reading by hundreds or thousands of nanoteslas. The converter does not know which component or which place a reading comes from.
Gauss and milligauss
Older documents and some consumer instruments use the gauss, the unit of the centimeter-gram-second system. One gauss is exactly 10^-4 tesla, which is 100 µT or 100,000 nT. One milligauss is 100 nT, or 0.1 µT. The Earth's field of about 0.5 gauss is 50 µT, and the converter lists gauss and milligauss as options so you can move a figure like 0.5 G to 50 µT in one step. Household magnetic field meters often display milligauss, so a reading of 2 mG is 0.2 µT, or 200 nT. When converting from gauss, note that the gauss measures magnetic flux density in the CGS system, and it should not be confused with the oersted, which is a unit of magnetic field strength. The page converts only flux density units.
Geomagnetic storms and variations
The Earth's field is not constant. Solar activity can disturb it, and the disturbances during geomagnetic storms are measured in nanoteslas. The Dst index, which tracks the strength of the ring current around the Earth, is reported in nT, and values below minus 100 nT are classified as intense storms. A change of minus 100 nT is 0.1 µT, a small fraction of the roughly 30 µT of the equatorial field at the surface, but large enough to affect power grids and satellites. Daily variations in quiet conditions are a few tens of nanoteslas. These are the kinds of numbers magnetometer networks record. A scientist who reads an observatory report in nT and compares it with a phone sensor in µT would use exactly this conversion. The phone is unlikely to resolve such small changes.
A second example: magnetic surveys and anomalies
In archaeological and mineral surveys, a magnetometer carried over the ground records the total field and looks for local anomalies. A buried iron object might raise the field by 20 nT above the background, which is 0.02 µT, and a fire pit or kiln might change it by a few nanoteslas. Survey instruments such as proton precession and optically pumped magnetometers resolve changes of 1 nT or less, which is 0.001 µT. In the same survey the background of 50,000 nT is 50 µT. The ratio of a 20 nT anomaly to the background is 0.04 percent. These numbers are illustrative, and the real values depend on the instrument and the site. The calculation shows why survey data are reported in nanoteslas: in microteslas the interesting variation would sit in the third decimal place.
The interplanetary field and very weak fields
The magnetic field carried by the solar wind near the Earth is typically of order 5 nT, which is 0.005 µT. Fields of the human body are much weaker still: the heart produces fields of tens of picoteslas, and the brain produces fields of tens to hundreds of femtoteslas, which are measured with superconducting sensors in shielded rooms. A picotesla is 0.001 nT, so 50 pT is 0.05 nT, and the converter handles picoteslas as a source unit. These examples show the range over which magnetic fields are measured, from the roughly 50 µT of the Earth through nanoteslas in space, to picoteslas and below in biology. Figures are approximate and are given for orientation, not as specifications for any instrument or research study.
Sensor specifications and noise
Magnetometer data sheets quote resolution and noise in nanoteslas or microteslas, and the unit changes with the technology. A typical consumer MEMS magnetometer might resolve about 0.1 µT, which is 100 nT, while a fluxgate sensor reaches noise levels of around 10 pT per root hertz and an optically pumped magnetometer even lower. Comparing two data sheets requires matching units and also matching conditions such as bandwidth. A sensor with 100 nT resolution cannot see a 20 nT anomaly, but it easily sees a 48 µT field. The converter takes care of the prefix step, and the user must check the measurement bandwidth and what the noise figure represents. The numbers in this paragraph are typical orders of magnitude and not data for a particular product.
Common mistakes
The usual mistake is a factor of 1,000 between nT and µT, which turns a small anomaly into a large one or the reverse. Another is to confuse flux density with flux: the tesla measures density, and the weber measures total flux through an area. A third is to confuse the tesla with the gauss and to forget the factor of 10,000. A fourth is to assume a sensor reading is a scalar total field when it is one component of a vector, so that the reading changes as the sensor rotates. A fifth is to ignore calibration and offsets in consumer sensors, which are often several microteslas off until they are calibrated. The converter is only a prefix change and cannot correct for any of those issues.
Smartphone sensors and what they report
Most phones contain a three-axis magnetometer used for the compass, and many apps display its readings in microteslas. A typical reading while the phone is held away from metal is between about 25 and 65 µT in total magnitude, depending on where you are. If an app shows the three components as, for example, 12 µT, minus 4 µT and minus 42 µT, the total field is the square root of 144 plus 16 plus 1,764, which is about 43.9 µT, or 43,900 nT. Nearby steel, speakers, magnetic cases and electrical cables change the reading by many microteslas, and the sensor often needs calibration by waving the phone in a figure of eight. A researcher comparing such a reading with an observatory value in nanoteslas should expect differences of several thousand nanoteslas from local sources alone.
Spacecraft and observatory data
Magnetometers on spacecraft and at ground observatories publish data in nanoteslas because the signals of interest are small compared with the total field. A magnetic observatory records the field every second or every minute with a resolution of 0.01 nT or better, and quiet-day variations of a few tens of nanoteslas are visible on the plot. A reading near 50,000 nT is 50 µT, and a storm disturbance of 300 nT is 0.3 µT. Publications that cover both near-Earth and interplanetary measurements sometimes switch between nT and µT in different figures. A reader who takes values from two figures must convert before comparing. The converter handles the step in one move, and the digits are exact. Remember that published values may be a single component, such as the horizontal field, rather than the total field.
Scope and sources
The page converts a known magnetic flux density between SI-prefixed units, gauss and milligauss. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not assess exposure to magnetic fields. The definitions of the tesla, the gauss relation and the prefixes come from the BIPM SI Brochure and NIST Special Publication 811. For regulated exposure questions, use the standard and the measurement method that the regulator specifies, and for instrument performance rely on the manufacturer data.