Survey instruments speak in nanoteslas

Fluxgate and proton precession magnetometers used in magnetic surveys display field strength in nanoteslas, because the changes of interest are small compared with the total field. Phone apps, hobby sensors and some datasheets use µT. Converting from µT to nT multiplies by 1,000, so 50 µT becomes 50,000 nT. This page does the shift so that a reading from one source can be set beside a reading from another. The tesla and its prefixes are defined in the BIPM SI Brochure, and the factor between neighboring thousands is exact. In magnetic survey work, nT is the standard unit for anomaly maps.

The total field and anomalies

The geomagnetic field at the surface is typically between about 25 and 65 µT, which is 25,000 to 65,000 nT, depending on location. A survey does not look at this large background but at differences of a few nT to hundreds of nT caused by buried iron, pipes or geology. A reading of 48 µT is 48,000 nT. If a pipe locator or a metal detector survey shows a local change of 300 nT, that is 0.3 µT, less than one percent of the total field. The same ratio explains why a magnetometer survey is done with a steady walking pace and without keys, belts or phones in the pockets: a steel buckle can add more than that to a reading. Surveyors also note the sensor height above the ground, because the signal from a buried object falls off quickly with distance. Seeing the numbers in one unit makes the relative size clear.

Utilities, pipes and old foundations

Contractors and land surveyors use magnetometers to locate buried steel tanks, drums, pipes and foundations before digging. Instruments report a total field in nT or a gradient in nT per meter. A contractor comparing a phone reading with a survey instrument needs both in the same unit. A hit of 2,000 nT above the local background is 2 µT. The size of an anomaly depends on the mass of iron and its depth, and falls quickly with distance, so the survey line spacing matters. The conversion is the first step in reading a log, and interpretation belongs to the survey professional. A homeowner who suspects an old buried oil tank can use the same idea on a small scale: walk a grid with a sensitive magnetometer, log the readings in nT, and look for a rise above the neighboring values. A smooth change of a few tens of nT across the yard is usually geology or the ground itself, while a sharp peak of hundreds or thousands of nT over a few meters suggests iron close to the surface. Mark the grid with stakes so the survey can be repeated.

Default value and a quick scale

The default of 10 µT gives 10,000 nT. It is below the typical outdoor value, which suggests that the reading was taken indoors or near a source that reduces the field, or that the number is only an example. Other values: 0.3 µT is 300 nT, 1 µT is 1,000 nT and 0.02 µT is 20 nT. The last is the order of magnitude of a diurnal variation in quiet conditions at mid latitudes, which is a few tens of nT. Using nT shows variations that would be lost in rounding if the same readings were shown in µT.

Drone and handheld magnetometer projects

Hobbyists and researchers add magnetometer modules to drones and carts for mapping. The modules output raw counts that the driver converts to µT or nT, and the board documentation lists sensitivity in one of the two units. A module with a resolution of 0.1 µT cannot resolve a 20 nT anomaly, while one with a resolution of 10 nT can. Compare the resolution with the signal in the same unit before you build the system. Mount the sensor away from motors, batteries and wiring that create fields of their own, and calibrate for hard and soft iron effects. A boom that holds the sensor one or two meters from the frame is a common way to reduce the field of the vehicle, and flying a straight line in two opposite directions shows whether a heading error is present. Log the raw values in the unit the driver uses, convert once to nT on the ground, and keep the conversion factor in the file header.

Noise and units in datasheets

Sensor datasheets list noise in nT per square root of hertz or in nT RMS over a bandwidth. A sensor with noise of 10 nT RMS is quieter than one with 0.5 µT RMS by a factor of 50, since 0.5 µT equals 500 nT. Write the values in one unit in a comparison table. If you use the sensor at a lower bandwidth, the noise falls, so keep the bandwidth note with the number. The conversion helps with the first step, getting everything to nT, and the datasheet notes tell you the conditions. Compare also the range: a sensor that covers plus or minus 100 µT, which is plus or minus 100,000 nT, handles the geomagnetic field without saturating, while one with a range of plus or minus 5 µT cannot. A sensor with a fine resolution and a small range suits a shielded setup, and a coarse sensor with a wide range suits a vehicle or a phone, so look at both numbers in one unit before you choose.

Diurnal variation and magnetic storms

The geomagnetic field is not constant. It has daily variation of a few tens of nT in quiet conditions, and storms can produce changes of hundreds of nT. Magnetic observatories publish data in nT, and agencies such as NOAA and the British Geological Survey provide reports. A survey that takes hours can therefore show a drift that has nothing to do with the buried object. Surveyors use a base station magnetometer to correct for it. If you compare your phone reading in µT with an observatory in nT, convert and expect agreement only within the limits of your sensor.

Hand checks

Move the decimal point three places to the right to go from µT to nT. A reading of 0.045 µT is 45 nT, and 52.3 µT is 52,300 nT. To go back, move three places left. If the page returns a number that is not three orders of magnitude larger than the input, one of the menus is set incorrectly. Keep the unit next to every number in a log, and prefer the unit your instrument manual uses, so that the entries remain easy to compare with it.

Magnetometer surveys need calibrated instruments

The page converts a magnetic flux density value from µT to nT. It does not correct for temperature, calibrate a sensor or interpret an anomaly. A survey that supports a construction or safety decision should be planned and interpreted by a qualified professional, using instruments with documented calibration. The factor is exact, and the accuracy of the result depends on the quality of the measurement.