Hall sensor data sheets against a magnetometer log
Hall-effect switches and linear sensors list their operating thresholds and sensitivity in millitesla or gauss, while a precision magnetometer used to survey a test bench records in nanoteslas. A designer who wants to know whether the stray field at a bench is small compared with a switch threshold of a few millitesla needs both numbers in one unit. This page divides the nanotesla value by one million and returns millitesla. It also helps students comparing a textbook figure for a magnet with a survey value, and technicians who read specifications from several manufacturers. The page changes the unit and says nothing about how a particular sensor will behave in your application.
Six decades between nano and milli
Milli stands for 10^-3 and nano for 10^-9, so one millitesla equals 10^6 nanoteslas. The formula is mT = nT × 0.000001. The tesla is the SI unit of magnetic flux density, equal to one weber per square meter, and the BIPM SI Brochure and NIST SP 811 define the prefixes. The factor is exact. By hand, move the decimal point six places to the left. 2,500,000 nT is 2.5 mT, 400,000 nT is 0.4 mT and 50,000 nT is 0.05 mT. In the other direction, 8 mT is 8,000,000 nT. Go through microteslas if you like, since 1,000 nT is 1 µT and 1,000 µT is 1 mT. A reading of 750,000 nT is 0.75 mT.
Earth field at 50,000 nT against a Hall switch
The default of 10 nT returns 0.00001 mT, one hundred-thousandth of a millitesla. A more familiar reference is the natural field at the surface of the Earth, roughly 25,000 to 65,000 nT, which is 0.025 to 0.065 mT. A field of 50,000 nT is 0.05 mT. A Hall switch that needs a few millitesla to operate is therefore insensitive to the Earth field by a factor of dozens, which is the point of the design. A tiny result with many leading zeros is a hint to move to a smaller unit for reporting. Choose nanoteslas or microteslas for weak fields and millitesla for magnets and coils.
Stray fields around a bench
Power supplies, motors and cables create stray fields that can disturb a sensitive measurement. A bench survey might find 120,000 nT near a transformer, which is 0.12 mT, and 3,000 nT a meter away, which is 0.003 mT. Converting both to millitesla lets you compare them with a sensor specification that lists an operating range of a few millitesla. If the stray field is a tenth of the sensor threshold, a design review may flag it. The page does not know your layout or how fields add, so use it for the unit change and decide on acceptable limits from the sensor data sheet and your own tests. A bench where the field never exceeds 0.003 mT leaves a margin of 1,000 against a 3 mT threshold.
Magnets in the millitesla range
Small permanent magnets, such as those in cabinet latches and toys, have surface fields of tens to hundreds of millitesla, and the field drops quickly with distance. A reading of 80 mT at the surface is 80,000,000 nT, a number that shows why a sensitive magnetometer next to a magnet saturates. At a few centimeters the same magnet may read a few millitesla, and a magnetometer set to nanotesla ranges would be overwhelmed. Pick an instrument whose range includes the field you expect. Entering an expected value in the page helps you see which scale you need. The conversion does not model the field of any magnet, since its shape and material matter.
Gauss and millitesla together
Older data sheets give fields in gauss, and one millitesla equals 10 gauss. A threshold of 30 gauss is 3 mT, which is 3,000,000 nT. Devices designed in the United States often use gauss, while European data sheets lean toward millitesla, so a bill of materials can contain both. The page can help you connect them: a stray field of 50,000 nT is 0.05 mT and 0.5 G, and a sensor with an operating point of 3 mT is 30 G. When you create a comparison table, choose one unit for the entire column and convert each source before you enter it, so that a quick scan shows the ordering of the numbers correctly.
Reading the direction and axis of a field
A flux density is a vector, and sensors respond to a component along their sensitive axis. A magnetometer that reports a total magnitude from three axes will show a different number from a single-axis Hall sensor in the same field. The page converts a magnitude you supply. If you read 40,000 nT on one axis and 30,000 nT on another, the vector magnitude is 50,000 nT, which is 0.05 mT, and not 70,000 nT. Pythagoras applies to perpendicular components. Always write which component or magnitude each number represents, and use the same convention across a document so that comparisons stay meaningful.
Mixing up the milli and micro prefixes
The symbols mT and µT differ by one letter, and the values differ by a factor of 1,000. A phone app that shows 48 µT is displaying 0.048 mT, and a magnet data sheet that lists 48 mT describes a field a thousand times larger. Reading one as the other is a common slip. In plain text, uT usually stands for µT, and MT would be megatesla, which does not occur in ordinary work. Check the context against what you know: the Earth field is tens of microteslas, a fridge magnet is millitesla and an MRI scanner is teslas. When a number does not fit its context, check the prefix first.
A 1 percent magnetometer and a 2.5 mT reading
Force on a magnet, Hall sensor output voltage, material effects and the safety of a setup all need geometry, material data and the sensor specification. A converted figure also carries the uncertainty of the measurement: a magnetometer with an accuracy of 1 percent gives a millitesla figure with the same relative uncertainty, so a 2.5 mT reading is uncertain by 0.025 mT, which is 25,000 nT. For design or safety decisions, rely on manufacturer data sheets, relevant standards and qualified staff. The page gives a quick, exact change of unit, and what you do with the result is a separate matter. Quoting the reading as 2.5 mT ± 0.025 mT keeps both numbers visible to the next reader.